DEUTSCH HD10 Connector Overview & Assembly Instructions (English)

Learn about our environmentally sealed DEUTSCH HD10 connectors that are heavily used for diagnostic connections in the trucking, agricultural, marine, mining, and construction industries. Watch this video for an overview of the connectors and for step-by-step instructions on inserting and removing contacts, as well as mating and unmating.

Contact Insertion

  1. Grasp the contact-wire assembly between the thumb and forefinger on the wire approximately one inch behind the contact crimp barrel.
  2. Hold the connector with the rear grommet facing you.
  3. Push the contact straight into the connector grommet until a positive stop is felt. The retaining fingers in the connector will snap behind the shoulder of the contact and lock it in place. A slight tug will confirm that it is properly sealed.

Contact Removal

  1. With a rear insert toward you, snap the appropriate size plastic tool over the wire of the contact to be removed.
  2. Slide the tool along the wire into the insert cavity until it engages the contact and resistance is felt. The contact retaining clip will be in the unlocked position.
  3. Pull the contact-wire assembly out of the connector.
  1. DEUTSCH Contact Crimping Instructions (English)

Learn how to crimp our DEUTSCH contacts. Watch this video for step-by-step instructions on crimping the contacts using hand tools.