CAT-CABLE-BREAKOUT Power Cable Breakouts  1
PRODUCT
  1. Energy & Power
  2. Power Cable Breakouts
  1. HEAT SHRINK HALOGEN-FREE CABLE BREAKOUTS CAT-CABLE-BREAKOUT
active
  • Material System Crosslinked Polyolefin
  • Power Cable Breakout Technology Heat Shrink
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating Yes
  • Power Cable Breakout Shrink Ratio > 2.5:1
  • Wall Style (Excluding Adhesive) Single
  • Component Design Heat Shrink
  • Coating Style Planar
  • Number of Branches & Legs 2
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Semi-Rigid
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Min) (Body) 10
  • Application Diameter (Max) (Body) 21
  • Cross-Section Area (Power Cable) 48
  • Application Diameter (Min) (Leg) 10
  • Application Diameter (Max) (Leg) 13
  • Expanded Inside Diameter (Min) (Body) 23
  • Expanded Inside Diameter (Min) (Leg) 7
  • Leg Length 17
  • Power Cable Breakout Overall Length 60
  • Recovered Inside Diameter (Max) (Body) 9.2
  • Recovered Inside Diameter (Max) (Leg) 2
  • Recovered Wall Thickness (Max) (Body) 2
  • Recovered Wall Thickness (Max) (Leg) 1.2
  • Body Length 20
  • Wall Thickness Thick/Heavy
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Flammability Non-Flame-Retardant
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Emission Free No
  • UL Rating No
  • CSA Certified No
  • Power Cable Breakout Product Availability AMERICAS
  • Minimum Order Quantity 5
  • Minimum Packaging Unit 5
  • Product Use Closure on power cables and telecom cables
  • Other Colors Available No
463721-000 Power Cable Breakouts  1
  • Material System Crosslinked Polyolefin
  • Power Cable Breakout Technology Heat Shrink
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating Yes
  • Power Cable Breakout Shrink Ratio > 2.5:1
  • Wall Style (Excluding Adhesive) Single
  • Component Design Heat Shrink
  • Coating Style Planar
  • Number of Branches & Legs 4
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Semi-Rigid
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Min) (Body) 30
  • Application Diameter (Max) (Body) 89
  • Application Diameter (Min) (Leg) 14
  • Application Diameter (Max) (Leg) 36
  • Expanded Inside Diameter (Min) (Body) 100
  • Expanded Inside Diameter (Min) (Leg) 40
  • Leg Length 51
  • Power Cable Breakout Overall Length 223
  • Recovered Inside Diameter (Max) (Body) 31
  • Recovered Inside Diameter (Max) (Leg) 13.5
  • Recovered Wall Thickness (Max) (Body) 3.5
  • Recovered Wall Thickness (Max) (Leg) 2.5
  • Body Length 103
  • Wall Thickness Thick/Heavy
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Flammability Non-Flame-Retardant
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Emission Free No
  • UL Rating No
  • CSA Certified No
  • Power Cable Breakout Product Availability AMERICAS
  • Minimum Order Quantity 3
  • Standard Pack 3
  • Other Colors Available No
642845-000 Power Cable Breakouts  1
  • Material System Crosslinked Polyolefin
  • Power Cable Breakout Technology Heat Shrink
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating Yes
  • Power Cable Breakout Shrink Ratio > 2:1
  • Wall Style (Excluding Adhesive) Single
  • Component Design Heat Shrink
  • Coating Style Planar
  • Number of Branches & Legs 2
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Semi-Rigid
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Min) (Body) 9
  • Application Diameter (Max) (Body) 25
  • Application Diameter (Min) (Leg) 4
  • Application Diameter (Max) (Leg) 14
  • Expanded Inside Diameter (Min) (Body) 1.1
  • Expanded Inside Diameter (Min) (Leg) 15
  • Leg Length 25
  • Power Cable Breakout Overall Length 90
  • Recovered Inside Diameter (Max) (Body) 9.2
  • Recovered Inside Diameter (Max) (Leg) 4.1
  • Recovered Wall Thickness (Max) (Body) 3.2
  • Recovered Wall Thickness (Max) (Leg) 1.6
  • Body Length 20
  • Wall Thickness Thick/Heavy
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Flammability Non-Flame-Retardant
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Application Seal Breakouts in Multiconductor Cables & Conduits.
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Emission Free No
  • UL Rating No
  • CSA Certified No
  • Power Cable Breakout Product Availability AMERICAS
  • Minimum Order Quantity 3
  • Standard Pack 3
  • Product Use For use on standard poly- or elastomeric insulated/jacketed multiconductor cables or cables in metal/plastic conduits.
  • Other Colors Available No
094307-000 Power Cable Breakouts  1
  • Material System Crosslinked Polyolefin
  • Power Cable Breakout Technology Heat Shrink
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating Yes
  • Power Cable Breakout Shrink Ratio > 2.5:1
  • Wall Style (Excluding Adhesive) Single
  • Component Design Heat Shrink
  • Coating Style Planar
  • Number of Branches & Legs 4
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Semi-Rigid
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Min) (Body) 18
  • Application Diameter (Max) (Body) 32
  • Application Diameter (Min) (Leg) 4
  • Application Diameter (Max) (Leg) 11
  • Expanded Inside Diameter (Min) (Body) 45
  • Expanded Inside Diameter (Min) (Leg) 14
  • Leg Length 25
  • Power Cable Breakout Overall Length 97
  • Recovered Inside Diameter (Max) (Body) 16.5
  • Recovered Inside Diameter (Max) (Leg) 3.5
  • Recovered Wall Thickness (Max) (Body) 2.5
  • Recovered Wall Thickness (Max) (Leg) 1.9
  • Body Length 73
  • Wall Thickness Thick/Heavy
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Flammability Non-Flame-Retardant
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Emission Free No
  • UL Rating No
  • CSA Certified No
  • Power Cable Breakout Product Availability AMERICAS
  • Minimum Order Quantity 3
  • Standard Pack 3
  • Other Colors Available No
226877-000 Power Cable Breakouts  1
  • Material System Crosslinked Polyolefin
  • Power Cable Breakout Technology Heat Shrink
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating Yes
  • Power Cable Breakout Shrink Ratio > 2.5:1
  • Wall Style (Excluding Adhesive) Single
  • Component Design Heat Shrink
  • Coating Style Planar
  • Number of Branches & Legs 3
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Semi-Rigid
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Min) (Body) 28
  • Application Diameter (Max) (Body) 74
  • Application Diameter (Min) (Leg) 13
  • Application Diameter (Max) (Leg) 32
  • Expanded Inside Diameter (Min) (Body) 95
  • Expanded Inside Diameter (Min) (Leg) 44
  • Leg Length 45
  • Power Cable Breakout Overall Length 205
  • Recovered Inside Diameter (Max) (Body) 28
  • Recovered Inside Diameter (Max) (Leg) 13
  • Recovered Wall Thickness (Max) (Body) 3.5
  • Recovered Wall Thickness (Max) (Leg) 2.5
  • Body Length 90
  • Wall Thickness Thick/Heavy
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Flammability Non-Flame-Retardant
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Emission Free No
  • UL Rating No
  • CSA Certified No
  • Power Cable Breakout Product Availability AMERICAS
  • Minimum Order Quantity 3
  • Standard Pack 3
  • Other Colors Available No
861763-000 Power Cable Breakouts  1
  • Material System Crosslinked Polyolefin
  • Power Cable Breakout Technology Heat Shrink
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating Yes
  • Power Cable Breakout Shrink Ratio > 2.5:1
  • Wall Style (Excluding Adhesive) Single
  • Component Design Heat Shrink
  • Coating Style Planar
  • Number of Branches & Legs 3
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Semi-Rigid
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Min) (Body) 60
  • Application Diameter (Max) (Body) 144
  • Application Diameter (Min) (Leg) 30
  • Application Diameter (Max) (Leg) 53
  • Expanded Inside Diameter (Min) (Body) 170
  • Expanded Inside Diameter (Min) (Leg) 60
  • Leg Length 66
  • Power Cable Breakout Overall Length 252
  • Recovered Inside Diameter (Max) (Body) 60
  • Recovered Inside Diameter (Max) (Leg) 30
  • Recovered Wall Thickness (Max) (Body) 4.2
  • Recovered Wall Thickness (Max) (Leg) 2.6
  • Body Length 90
  • Wall Thickness Thick/Heavy
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Flammability Non-Flame-Retardant
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Emission Free No
  • UL Rating No
  • CSA Certified No
  • Power Cable Breakout Product Availability AMERICAS
  • Minimum Order Quantity 3
  • Standard Pack 3
  • Other Colors Available No
775717-000 Power Cable Breakouts  1
  • Material System Crosslinked Polyolefin
  • Power Cable Breakout Technology Heat Shrink
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating Yes
  • Power Cable Breakout Shrink Ratio > 2.5:1
  • Wall Style (Excluding Adhesive) Single
  • Component Design Heat Shrink
  • Coating Style Planar
  • Number of Branches & Legs 4
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Semi-Rigid
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Min) (Body) 25
  • Application Diameter (Max) (Body) 53
  • Application Diameter (Min) (Leg) 9
  • Application Diameter (Max) (Leg) 23
  • Expanded Inside Diameter (Min) (Body) 75
  • Expanded Inside Diameter (Min) (Leg) 25
  • Leg Length 44
  • Power Cable Breakout Overall Length 217
  • Recovered Inside Diameter (Max) (Body) 25
  • Recovered Inside Diameter (Max) (Leg) 9
  • Recovered Wall Thickness (Max) (Body) 3.5
  • Recovered Wall Thickness (Max) (Leg) 2
  • Body Length 100
  • Wall Thickness Thick/Heavy
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Flammability Non-Flame-Retardant
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Emission Free No
  • UL Rating No
  • CSA Certified No
  • Power Cable Breakout Product Availability AMERICAS
  • Minimum Order Quantity 3
  • Standard Pack 3
  • Other Colors Available No
659585-000 Power Cable Breakouts  1
  • Material System Crosslinked Polyolefin
  • Power Cable Breakout Technology Heat Shrink
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating Yes
  • Power Cable Breakout Shrink Ratio > 2.5:1
  • Wall Style (Excluding Adhesive) Single
  • Component Design Heat Shrink
  • Coating Style Planar
  • Number of Branches & Legs 3
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Semi-Rigid
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Min) (Body) 13
  • Application Diameter (Max) (Body) 34
  • Application Diameter (Min) (Leg) 5
  • Application Diameter (Max) (Leg) 14
  • Expanded Inside Diameter (Min) (Body) 38
  • Expanded Inside Diameter (Min) (Leg) 16
  • Leg Length 28
  • Power Cable Breakout Overall Length 103
  • Recovered Inside Diameter (Max) (Body) 13
  • Recovered Inside Diameter (Max) (Leg) 4.2
  • Recovered Wall Thickness (Max) (Body) 2.7
  • Recovered Wall Thickness (Max) (Leg) 1.5
  • Body Length 45
  • Wall Thickness Thick/Heavy
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Flammability Non-Flame-Retardant
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Emission Free No
  • UL Rating No
  • CSA Certified No
  • Power Cable Breakout Product Availability AMERICAS
  • Minimum Order Quantity 3
  • Standard Pack 3
  • Other Colors Available No
642409-000 Power Cable Breakouts  1
  • Material System Crosslinked Polyolefin
  • Power Cable Breakout Technology Heat Shrink
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating Yes
  • Power Cable Breakout Shrink Ratio > 2.5:1
  • Wall Style (Excluding Adhesive) Single
  • Component Design Heat Shrink
  • Coating Style Planar
  • Number of Branches & Legs 4
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Semi-Rigid
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Min) (Body) 60
  • Application Diameter (Max) (Body) 154
  • Application Diameter (Min) (Leg) 23
  • Application Diameter (Max) (Leg) 38
  • Expanded Inside Diameter (Min) (Body) 170
  • Expanded Inside Diameter (Min) (Leg) 50
  • Leg Length 65
  • Power Cable Breakout Overall Length 255
  • Recovered Inside Diameter (Max) (Body) 60
  • Recovered Inside Diameter (Max) (Leg) 23
  • Recovered Wall Thickness (Max) (Body) 4
  • Recovered Wall Thickness (Max) (Leg) 2.5
  • Body Length 90
  • Wall Thickness Thick/Heavy
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Flammability Non-Flame-Retardant
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Emission Free No
  • UL Rating No
  • CSA Certified No
  • Power Cable Breakout Product Availability AMERICAS
  • Minimum Order Quantity 3
  • Standard Pack 3
  • Other Colors Available No
028145-000 Power Cable Breakouts  1
  • Material System Crosslinked Polyolefin
  • Power Cable Breakout Technology Heat Shrink
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating Yes
  • Power Cable Breakout Shrink Ratio > 2:1
  • Wall Style (Excluding Adhesive) Single
  • Component Design Heat Shrink
  • Coating Style Planar
  • Number of Branches & Legs 2
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Semi-Rigid
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Min) (Body) 32
  • Application Diameter (Max) (Body) 43
  • Application Diameter (Min) (Leg) 8
  • Application Diameter (Max) (Leg) 19
  • Expanded Inside Diameter (Min) (Body) 48
  • Expanded Inside Diameter (Min) (Leg) 22
  • Leg Length 70
  • Power Cable Breakout Overall Length 170
  • Recovered Inside Diameter (Max) (Body) 32
  • Recovered Inside Diameter (Max) (Leg) 7
  • Recovered Wall Thickness (Max) (Body) 2
  • Recovered Wall Thickness (Max) (Leg) 2
  • Wall Thickness Thick/Heavy
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Flammability Non-Flame-Retardant
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Emission Free No
  • UL Rating No
  • CSA Certified No
  • Power Cable Breakout Product Availability AMERICAS
  • Minimum Order Quantity 3
  • Standard Pack 3
  • Other Colors Available No
476449-000 Power Cable Breakouts  1
  • Material System Crosslinked Polyolefin
  • Power Cable Breakout Technology Heat Shrink
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating Yes
  • Power Cable Breakout Shrink Ratio > 2:1
  • Wall Style (Excluding Adhesive) Single
  • Component Design Heat Shrink
  • Coating Style Planar
  • Number of Branches & Legs 2
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Semi-Rigid
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Min) (Body) 42
  • Application Diameter (Max) (Body) 76
  • Application Diameter (Min) (Leg) 17
  • Application Diameter (Max) (Leg) 36
  • Expanded Inside Diameter (Min) (Body) 86
  • Expanded Inside Diameter (Min) (Leg) 40
  • Leg Length 75
  • Power Cable Breakout Overall Length 200
  • Recovered Inside Diameter (Max) (Body) 42
  • Recovered Inside Diameter (Max) (Leg) 17
  • Recovered Wall Thickness (Max) (Body) 2.5
  • Recovered Wall Thickness (Max) (Leg) 2.5
  • Wall Thickness Thick/Heavy
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Flammability Non-Flame-Retardant
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Emission Free No
  • UL Rating No
  • CSA Certified No
  • Power Cable Breakout Product Availability AMERICAS
  • Minimum Order Quantity 3
  • Standard Pack 3
  • Other Colors Available No
774741-000 Power Cable Breakouts  1
  • Material System Crosslinked Polyolefin
  • Power Cable Breakout Technology Heat Shrink
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating Yes
  • Power Cable Breakout Shrink Ratio > 2.5:1
  • Wall Style (Excluding Adhesive) Single
  • Component Design Heat Shrink
  • Coating Style Planar
  • Number of Branches & Legs 3
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Semi-Rigid
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Min) (Body) 22
  • Application Diameter (Max) (Body) 56
  • Application Diameter (Min) (Leg) 9
  • Application Diameter (Max) (Leg) 23
  • Expanded Inside Diameter (Min) (Body) 63
  • Expanded Inside Diameter (Min) (Leg) 26
  • Leg Length 40
  • Power Cable Breakout Overall Length 180
  • Recovered Inside Diameter (Max) (Body) 22
  • Recovered Inside Diameter (Max) (Leg) 9
  • Recovered Wall Thickness (Max) (Body) 3.5
  • Recovered Wall Thickness (Max) (Leg) 1.5
  • Body Length 85
  • Wall Thickness Thick/Heavy
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Flammability Non-Flame-Retardant
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Emission Free No
  • UL Rating No
  • CSA Certified No
  • Power Cable Breakout Product Availability AMERICAS
  • Minimum Order Quantity 3
  • Standard Pack 3
  • Other Colors Available No
JOR-60350 Power Cable Breakouts  1
  • Material System Thermoplastic Elastomer (TPE)
  • Power Cable Breakout Technology Cold Applied
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating No
  • Wall Style (Excluding Adhesive) Round
  • Component Design Push-On
  • Coating Style Uncoated Only
  • Number of Branches & Legs 3
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Flexible
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Max) (Body) 8.5
  • Cross-Section Area (Power Cable) 1.5 – 4
  • Application Diameter (Max) (Leg) 2.8
  • Leg Length 14
  • Power Cable Breakout Overall Length 40
  • Body Length 24
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Application Termination of polymeric cables in house connection boxes, lighting poles, switchgear & transformer stations
  • Emission Free Yes
  • Power Cable Breakout Product Availability Worldwide
  • Standard Pack 10
  • Product Use Reliable termination of polymeric insulated cables
JOR-60352 Power Cable Breakouts  1
  • Material System Thermoplastic Elastomer (TPE)
  • Power Cable Breakout Technology Cold Applied
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating No
  • Wall Style (Excluding Adhesive) Round
  • Component Design Push-On
  • Coating Style Uncoated Only
  • Number of Branches & Legs 3
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Flexible
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Max) (Body) 14
  • Cross-Section Area (Power Cable) 6
  • Application Diameter (Max) (Leg) 4.3
  • Leg Length 16
  • Power Cable Breakout Overall Length 40
  • Body Length 24
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Application Termination of polymeric cables in house connection boxes, lighting poles, switchgear & transformer stations
  • Emission Free Yes
  • Power Cable Breakout Product Availability Worldwide
  • Standard Pack 10
  • Product Use Reliable termination of polymeric insulated cables
JOR-60354 Power Cable Breakouts  1
  • Material System Thermoplastic Elastomer (TPE)
  • Power Cable Breakout Technology Cold Applied
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating No
  • Wall Style (Excluding Adhesive) Round
  • Component Design Push-On
  • Coating Style Uncoated Only
  • Number of Branches & Legs 3
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Flexible
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Max) (Body) 14
  • Cross-Section Area (Power Cable) 10
  • Application Diameter (Max) (Leg) 5.5
  • Leg Length 16
  • Power Cable Breakout Overall Length 40
  • Body Length 24
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Application Termination of polymeric cables in house connection boxes, lighting poles, switchgear & transformer stations
  • Emission Free Yes
  • Power Cable Breakout Product Availability Worldwide
  • Standard Pack 10
  • Product Use Reliable termination of polymeric insulated cables
JOR-60356 Power Cable Breakouts  1
  • Material System Thermoplastic Elastomer (TPE)
  • Power Cable Breakout Technology Cold Applied
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating No
  • Wall Style (Excluding Adhesive) Round
  • Component Design Push-On
  • Coating Style Uncoated Only
  • Number of Branches & Legs 3
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Flexible
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Max) (Body) 19
  • Cross-Section Area (Power Cable) 16
  • Application Diameter (Max) (Leg) 6
  • Leg Length 22
  • Power Cable Breakout Overall Length 50
  • Body Length 28
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Application Termination of polymeric cables in house connection boxes, lighting poles, switchgear & transformer stations
  • Emission Free Yes
  • Power Cable Breakout Product Availability Worldwide
  • Standard Pack 10
  • Product Use Reliable termination of polymeric insulated cables
JOR-60358 Power Cable Breakouts  1
  • Material System Thermoplastic Elastomer (TPE)
  • Power Cable Breakout Technology Cold Applied
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating No
  • Wall Style (Excluding Adhesive) Round
  • Component Design Push-On
  • Coating Style Uncoated Only
  • Number of Branches & Legs 3
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Flexible
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Max) (Body) 21.5
  • Cross-Section Area (Power Cable) 25
  • Application Diameter (Max) (Leg) 8
  • Leg Length 24
  • Power Cable Breakout Overall Length 60
  • Body Length 36
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Application Termination of polymeric cables in house connection boxes, lighting poles, switchgear & transformer stations
  • Emission Free Yes
  • Power Cable Breakout Product Availability Worldwide
  • Standard Pack 10
  • Product Use Reliable termination of polymeric insulated cables
JOR-60370 Power Cable Breakouts  1
  • Material System Thermoplastic Elastomer (TPE)
  • Power Cable Breakout Technology Cold Applied
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating No
  • Wall Style (Excluding Adhesive) Round
  • Component Design Push-On
  • Coating Style Uncoated Only
  • Number of Branches & Legs 4
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Flexible
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Max) (Body) 9.5
  • Cross-Section Area (Power Cable) 1.5 – 2.5
  • Application Diameter (Max) (Leg) 2.8
  • Leg Length 16
  • Power Cable Breakout Overall Length 40
  • Body Length 24
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Application Termination of polymeric cables in house connection boxes, lighting poles, switchgear & transformer stations
  • Emission Free Yes
  • Power Cable Breakout Product Availability Worldwide
  • Standard Pack 10
  • Product Use Reliable termination of polymeric insulated cables
JOR-60371 Power Cable Breakouts  1
  • Material System Thermoplastic Elastomer (TPE)
  • Power Cable Breakout Technology Cold Applied
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating No
  • Wall Style (Excluding Adhesive) Round
  • Component Design Push-On
  • Coating Style Uncoated Only
  • Number of Branches & Legs 4
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Flexible
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Max) (Body) 12
  • Cross-Section Area (Power Cable) 4
  • Application Diameter (Max) (Leg) 3.8
  • Leg Length 16
  • Power Cable Breakout Overall Length 40
  • Body Length 24
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Application Termination of polymeric cables in house connection boxes, lighting poles, switchgear & transformer stations
  • Emission Free Yes
  • Power Cable Breakout Product Availability Worldwide
  • Standard Pack 10
  • Product Use Reliable termination of polymeric insulated cables
JOR-60372 Power Cable Breakouts  1
  • Material System Thermoplastic Elastomer (TPE)
  • Power Cable Breakout Technology Cold Applied
  • Power Cable Breakout Product Type Cable Breakout Boot
  • Adhesive Coating No
  • Wall Style (Excluding Adhesive) Round
  • Component Design Push-On
  • Coating Style Uncoated Only
  • Number of Branches & Legs 4
  • Power Cable Breakout Voltage Rating ≤ 1
  • Flexibility Flexible
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Max) (Body) 14
  • Cross-Section Area (Power Cable) 6
  • Application Diameter (Max) (Leg) 4.3
  • Leg Length 16
  • Power Cable Breakout Overall Length 40
  • Body Length 24
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Application Termination of polymeric cables in house connection boxes, lighting poles, switchgear & transformer stations
  • Emission Free Yes
  • Power Cable Breakout Product Availability Worldwide
  • Standard Pack 10
  • Product Use Reliable termination of polymeric insulated cables