CAT-R21-731072 Heat Shrink Boots  1
PRODUCT
  1. Harnessing
  2. Heat Shrink Boots
  1. Bulbous Heat Shrink Boots: Lipped, Straight CAT-R21-731072
active
  • Molded Part Shape Straight
  • Lipped Yes
  • Material Code 3
  • Heat Shrink Boot Material Systems Code 10
  • Adhesive Pre-Coat No
  • Material Semi-Rigid Modified Polyolefin
  • Cable Diameter Range 5.6 – 12.4
  • Wire/Cable Outside Diameter .236 in
  • Operating Temperature Range -75 – 150
  • Power Cable Accessory No
  • Approved Standards BR1326 listed Class G
  • Government Qualified No
  • Molded Part Shape Code 202
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Options /180 Precoat
  • Adhesive Type General Purpose Pre-Coat Adhesive
CAT-R21-7310654 Heat Shrink Boots  1
PRODUCT
  1. Harnessing
  2. Heat Shrink Boots
  1. Heat Shrink Boots: Non Lipped, Right Angle CAT-R21-7310654
active
  • Molded Part Shape 90°
  • Lipped No
  • Material Code 3
  • Heat Shrink Boot Material Systems Code 10
  • Adhesive Pre-Coat No
  • Material Polyolefin Flexible Modified
  • Cable Diameter Range 6.4 – 20.6
  • Wire/Cable Outside Diameter .276 in
  • Operating Temperature Range -75 – 150
  • Power Cable Accessory No
  • Approved Standards BR1326 listed Class G
  • Government Qualified No
  • Molded Part Shape Code 222
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Options /180 Precoat
  • Adhesive Type General Purpose Pre-Coat Adhesive
CAT-R21-73106549 Heat Shrink Boots  1
PRODUCT
  1. Harnessing
  2. Heat Shrink Boots
  1. Bulbous Heat Shrink Boots: Lipped, Right Angle CAT-R21-73106549
active
  • Molded Part Shape 90°
  • Lipped Yes
  • Material Code 3
  • Heat Shrink Boot Material Systems Code 10
  • Adhesive Pre-Coat No
  • Material Semi-Rigid Modified Polyolefin
  • Cable Diameter Range 5.9 – 14
  • Wire/Cable Outside Diameter .276 in
  • Operating Temperature Range -75 – 150
  • Power Cable Accessory No
  • Approved Standards BR1326 listed Class G
  • Government Qualified No
  • Molded Part Shape Code 222
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Options /180 Precoat
  • Adhesive Type General Purpose Pre-Coat Adhesive
CAT-R21-731055 Heat Shrink Boots  1
PRODUCT
  1. Harnessing
  2. Heat Shrink Boots
  1. Low Profile Heat Shrink Boots: Poly Mold, Lipped, Right Angle CAT-R21-731055
active
  • Molded Part Shape 90°
  • Lipped Yes
  • Material Code 3
  • Heat Shrink Boot Material Systems Code 10
  • Adhesive Pre-Coat No
  • Material Polyolefin Flexible Modified
  • Cable Diameter Range 6.4 – 14
  • Wire/Cable Outside Diameter .276 in
  • Operating Temperature Range -75 – 150
  • Power Cable Accessory No
  • Approved Standards BS-G-198-5-DA
  • Government Qualified No
  • Molded Part Shape Code 222
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Options /225 Precoat
  • Adhesive Type General Purpose Pre-Coat Adhesive
CAT-R21-73106 Heat Shrink Boots  1
PRODUCT
  1. Harnessing
  2. Heat Shrink Boots
  1. Feedthrough Heat Shrink Boots: Non Lipped, Straight CAT-R21-73106
active
  • Molded Part Shape Straight
  • Lipped No
  • Material Code 3
  • Heat Shrink Boot Material Systems Code 10
  • Adhesive Pre-Coat No
  • Operating Temperature Range -75 – 150
  • Molded Part Shape Code 207W
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Options /180 Precoat
CAT-R21-73105 Heat Shrink Boots  1
PRODUCT
  1. Harnessing
  2. Heat Shrink Boots
  1. Heat Shrink Boots: Micro Molded, Lipped, Right Angle CAT-R21-73105
active
  • Molded Part Shape 90°
  • Lipped Yes
  • Material Code 12
  • Heat Shrink Boot Material Systems Code 25
  • Adhesive Pre-Coat No
  • Material Fluid Resistant Modified Elastomer
  • Operating Temperature Range -75 – 150
  • Flammability Flame-Retardant
  • Power Cable Accessory No
  • Approved Standards SAE AS81765/4
  • Molded Part Shape Code 224
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Options /225 Precoat
CAT-R21-567014 Heat Shrink Boots  1
PRODUCT
  1. Harnessing
  2. Heat Shrink Boots
  1. Low Profile HS Boots: Blow Molded, Slim Line, Lipped, Straight CAT-R21-567014
active
  • Molded Part Shape Straight
  • Lipped Yes
  • Material Code 50
  • Heat Shrink Boot Material Systems Code 10
  • Adhesive Pre-Coat No
  • Material Semi-Rigid Modified Polyolefin
  • Cable Diameter Range 6.6 – 15.6
  • Wire/Cable Outside Diameter .276 in
  • Operating Temperature Range -65 – 200
  • Power Cable Accessory No
  • Approved Standards AS SAE81765/1 Type II
  • Government Qualified No
  • Molded Part Shape Code 202
  • Fluid/Chemical Resistance Chemical, Biological, Radiological and Nuclear (CBRN)
  • Adhesive Options /42 Precoat
  • Adhesive Type Adhesive Purchased Separately
CAT-R21-7310723 Heat Shrink Boots  1
PRODUCT
  1. Harnessing
  2. Heat Shrink Boots
  1. Low Profile Heat Shrink Boots: Poly Molded, Lipped, Straight CAT-R21-7310723
active
  • Molded Part Shape Straight
  • Lipped Yes
  • Material Code 3
  • Heat Shrink Boot Material Systems Code 10
  • Adhesive Pre-Coat No
  • Material Polyolefin Flexible Modified
  • Cable Diameter Range 9.7 – 21.3
  • Wire/Cable Outside Diameter .43 in
  • Operating Temperature Range -75 – 150
  • Power Cable Accessory No
  • Approved Standards BR1326 listed Class G
  • Government Qualified No
  • Molded Part Shape Code 202
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Options /180 Precoat
  • Adhesive Type Adhesive Purchased Separately
CAT-R21-731 Heat Shrink Boots  1
PRODUCT
  1. Harnessing
  2. Heat Shrink Boots
  1. Heat Shrink Boots: Non Lipped, Straight CAT-R21-731
active
  • Molded Part Shape Straight
  • Lipped No
  • Material Code 3
  • Heat Shrink Boot Material Systems Code 10
  • Adhesive Pre-Coat No
  • Material Semi-Rigid Modified Polyolefin
  • Cable Diameter Range 3.8 – 11.9
  • Wire/Cable Outside Diameter .177 in
  • Operating Temperature Range -75 – 150
  • Power Cable Accessory No
  • Approved Standards BR1326 listed Class G
  • Government Qualified No
  • Molded Part Shape Code 202
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Options /180 Precoat
  • Adhesive Type High Performance Pre-Coat Adhesive
CAT-R21-731055422 Heat Shrink Boots  1
PRODUCT
  1. Harnessing
  2. Heat Shrink Boots
  1. Heat Shrink Boots: Poly Mold, Lipped CAT-R21-731055422
active
  • Molded Part Shape 120˚
  • Lipped Yes
  • Material Code 3
  • Heat Shrink Boot Material Systems Code 10
  • Adhesive Pre-Coat No
  • Material Fluid Resistant Modified Elastomer
  • Cable Diameter Range 21.4 – 36
  • Inside Diameter as Supplied 36
  • Operating Temperature Range -75 – 150
  • Power Cable Accessory No
  • Approved Standards DEF Std 59-97 Issue 3 Type DA
  • Molded Part Shape Code 242
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Options /225 Precoat
  • Adhesive Type Adhesive Purchased Separately
CAT-R21-73107237 Heat Shrink Boots  1
PRODUCT
  1. Harnessing
  2. Heat Shrink Boots
  1. Heat Shrink Boots: Lipped, Straight CAT-R21-73107237
active
  • Molded Part Shape Straight
  • Lipped Yes
  • Material Code 3
  • Heat Shrink Boot Material Systems Code 10
  • Adhesive Pre-Coat No
  • Material Modified Fluoro-Elastomer
  • Cable Diameter Range 2.6 – 5.5
  • Wire/Cable Outside Diameter .12 in
  • Operating Temperature Range -75 – 150
  • Power Cable Accessory No
  • Approved Standards BR1326 listed Class G
  • Government Qualified No
  • Molded Part Shape Code 202
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Options /180 Precoat
  • Adhesive Type Adhesive Purchased Separately
CAT-R21-56701 Heat Shrink Boots  1
PRODUCT
  1. Harnessing
  2. Heat Shrink Boots
  1. Convoluted Heat Shrink Uni Boots: Lipped, Straight CAT-R21-56701
active
  • Molded Part Shape Straight
  • Lipped Yes
  • Material Code 50
  • Heat Shrink Boot Material Systems Code 10
  • Adhesive Pre-Coat No
  • Material Modified Fluoro-Elastomer
  • Cable Diameter Range 17.5 – 36
  • Wire/Cable Outside Diameter .787 in
  • Operating Temperature Range -65 – 200
  • Power Cable Accessory No
  • Approved Standards AS SAE81765/1 Type II
  • Government Qualified No
  • Molded Part Shape Code 202
  • Fluid/Chemical Resistance Chemical, Biological, Radiological and Nuclear (CBRN)
  • Adhesive Options /42 Precoat
  • Adhesive Type Adhesive Purchased Separately
CAT-R21-7310554 Heat Shrink Boots  1
PRODUCT
  1. Harnessing
  2. Heat Shrink Boots
  1. Heat Shrink Boots: Lipped, Right Angle CAT-R21-7310554
active
  • Molded Part Shape 90°
  • Lipped Yes
  • Material Code 3
  • Heat Shrink Boot Material Systems Code 10
  • Adhesive Pre-Coat No
  • Material Polyolefin Flexible Modified
  • Cable Diameter Range 2.1 – 4.5
  • Wire/Cable Outside Diameter .09 in
  • Operating Temperature Range -75 – 150
  • Power Cable Accessory No
  • Approved Standards BR1326 listed Class G
  • Government Qualified No
  • Molded Part Shape Code 222
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Options /180 Precoat
  • Adhesive Type General Purpose Pre-Coat Adhesive
CAT-R21-5670145 Heat Shrink Boots  1
PRODUCT
  1. Harnessing
  2. Heat Shrink Boots
  1. Slim Line Heat Shrink Boots: Non Lipped, Straight CAT-R21-5670145
active
  • Molded Part Shape Straight
  • Lipped No
  • Material Code 50
  • Heat Shrink Boot Material Systems Code 10
  • Adhesive Pre-Coat No
  • Material Modified Fluoro-Elastomer
  • Inside Diameter as Supplied 12.7
  • Operating Temperature Range -55 – 135
  • Power Cable Accessory No
  • Approved Standards AS SAE81765/1 Type II
  • Government Qualified No
  • Molded Part Shape Code 202
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Options /42 Precoat
  • Adhesive Type Adhesive Purchased Separately
CAT-R21-56701458 Heat Shrink Boots  1
PRODUCT
  1. Harnessing
  2. Heat Shrink Boots
  1. Low Profile Heat Shrink Boots: Blow Mold, Lipped, Right Angle CAT-R21-56701458
active
  • Molded Part Shape 90°
  • Lipped Yes
  • Material Code 50
  • Heat Shrink Boot Material Systems Code 10
  • Adhesive Pre-Coat No
  • Material Modified Fluoro-Elastomer
  • Cable Diameter Range 7.6 – 17.5
  • Wire/Cable Outside Diameter .35 in
  • Operating Temperature Range -55 – 125
  • Power Cable Accessory No
  • Approved Standards AS SAE81765/1 Type II
  • Government Qualified No
  • Molded Part Shape Code 222
  • Fluid/Chemical Resistance Chemical, Biological, Radiological and Nuclear (CBRN)
  • Adhesive Options /42 Precoat
  • Adhesive Type Adhesive Purchased Separately
202S174-25C-0 EMI Shielded Boots  1
PRODUCT
  1. Harnessing
  2. EMI Shielded Boots
  1. 202S174-25C-0 202S174-25C-0
active
  • Molded Part Type EMI Shielded Molded Parts
  • Angle Straight
  • Product Type Molded Part
  • Material Code 25
  • EMI Shielded Boot Color Black
  • EMI Shielded Boot Material Systems Code 25
  • EMI Shielded Boot Material Modified Elastomer
  • Adhesive Pre-Coat No
  • Operating Temperature Range -75 – 150
  • EMI Shielded Boot Adhesive Type Adhesive Purchased Separately
382A034-4/42-0 Breakouts & Transitions
MODUK DEF STAN 59-97
  • Molded Part Shape Y Shape
  • Size Code 034
  • Number of Branches/Legs 3
  • Material Code 4
  • Breakout & Transition Material Systems Code 10
  • Adhesive Pre-Coat Yes
  • Material Polyolefin Flexible Modified
  • Inside Diameter Range (Leg 1) 12.4 – 26.9
  • Inside Diameter Range (Body) 18 – 38.6
  • Inside Diameter Range (Leg 2) 12.4 – 26.9
  • Operating Temperature Range -55 – 135
  • Power Cable Accessory No
  • Government Qualified No
  • Molded Part Shape Code 382A
  • Fluid/Chemical Resistance Occasional exposure to fluids
  • Adhesive Options /42 Precoat
  • Breakout & Transition Adhesive Type High Performance Pre-Coat Adhesive
  • Adhesive Code 42
382A023-3/86-0 Breakouts & Transitions
MODUK DEF STAN 59-97
  • Molded Part Shape Y Shape
  • Size Code 023
  • Number of Branches/Legs 3
  • Material Code 3
  • Breakout & Transition Material Systems Code 10
  • Adhesive Pre-Coat Yes
  • Material Semi-Rigid Modified Polyolefin
  • Inside Diameter Range (Leg 1) 6.1 – 13.2
  • Inside Diameter Range (Body) 12.4 – 26.9
  • Inside Diameter Range (Leg 2) 6.1 – 13.2
  • Operating Temperature Range -55 – 135
  • Power Cable Accessory No
  • Government Qualified No
  • Molded Part Shape Code 382A
  • Fluid/Chemical Resistance Occasional exposure to fluids
  • Adhesive Options /86 Precoat
  • Breakout & Transition Adhesive Type High Performance Pre-Coat Adhesive
  • Adhesive Code 86
F42-60-FR Breakouts & Transitions
  • Number of Branches/Legs 4
  • Material Code 3
  • Breakout & Transition Material Systems Code 10
  • Adhesive Pre-Coat No
  • Material Modified Polyolefin
  • Operating Temperature Range -55 – 200
  • Power Cable Accessory No
  • Government Qualified No
  • Breakout & Transition Adhesive Type Adhesive Purchased Separately
  • Comment Heavy Duty
D14-30FR Breakouts & Transitions
  • Size Code 14-30
  • Number of Branches/Legs 2
  • Material Code 3
  • Adhesive Pre-Coat Yes
  • Material Modified Polyolefin
  • Inside Diameter Range (Leg 1) 4.3 – 12.7
  • Inside Diameter Range (Body) 15.24 – 30.48
  • Inside Diameter Range (Leg 2) 4.3 – 12.7
  • Operating Temperature Range -55 – 90
  • Power Cable Accessory No
  • Government Qualified No
  • Adhesive Options /97 Precoat
  • Adhesive Code 97