CAT-CRSM-CT Power Cable Wraps  1
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around Cable Tap Splice
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Shrink Ratio > 2.5:1
  • Product Family CRSM
  • Component Design Heat Shrink
  • Coating Style Inline
  • Voltage Rating ≤ 1
  • Flexibility Semi-Rigid
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Max) 27
  • Application Diameter (Min) 11
  • Wall Thickness Medium
  • Recovered Wall Thickness (Max) 2
  • Expanded Inside Diameter (Min) 34
  • Recovered Inside Diameter (Max) 10
  • Sleeve Length 152
  • Compression Connector Length (Max) 51
  • Conductor Range (Main) 2 – 4/0
  • Conductor Range (Tap) 10 – 2
  • Flammability Non-Flame-Retardant
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • UV-Stabilized Yes, ASTM-G154
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Application RUS Accepted for Use with Compression & Split-Bolt Connectors. For Use on Standard Poly- or Elastomeric Insulated Cables.
  • Marine-Offshore-Shipbuilding Certified Yes
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Standards ANSI C119.1
  • Product Availability Worldwide
  • Standard Pack 10
  • Packaging Method Pieces in Polybag in Master Carton
  • Product Use Wrap-Around, Sealed Cable Tap Splice
CAT-CRSM Power Cable Wraps  1
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Shrink Ratio > 2.5:1
  • Product Family CRSM
  • Component Design Heat Shrink
  • Coating Style Inline
  • Flexibility Semi-Rigid
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Max) 27
  • Application Diameter (Min) 11
  • Wall Thickness Medium
  • Recovered Wall Thickness (Max) 1.7
  • Expanded Inside Diameter (Min) 34
  • Recovered Inside Diameter (Max) 10
  • Cut Length 750
  • Flammability Non-Flame-Retardant
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Application Cable Jacketing, Cable Repair, Rejacketing/Outer Protection on Joints/Splices, Insulation & Protection, Rail Application, Marine Application, Industrial Application, Underground Application, Multi-Purpose Application
  • Marine-Offshore-Shipbuilding Certified Yes
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Standards IEC 60684-3-214, IEC 60684-3-246 IEC 60684-3-247, HD631.2
  • Product Availability Worldwide
  • Packaging Method Pieces
  • Product Use Wrap-Around, Sealed Cable Tap Splice
  • Other Colors Available No
583022-000 Power Cable Wraps  1
HD CENELEC 631.2 IEC 60684-3-214 IEC 60684-3-246 IEC 60684-3-247
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Shrink Ratio > 2.5:1
  • Product Family RFSM
  • Component Design Heat Shrink
  • Coating Style Inline
  • Flexibility Semi-Rigid
  • Color Black, Outer Layer with Thermo-Indicative Paint
  • Mechanical Reinforcement Fiber-Reinforced
  • Application Diameter (Max) 113
  • Application Diameter (Min) 44
  • Wall Thickness Medium
  • Recovered Wall Thickness (Max) 4.5
  • Cut Length 1500
  • Flammability Non-Flame-Retardant
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Application Cable Jacketing, Cable Repair, Rejacketing/Outer Protection on Joints/Splices, Insulation & Protection, Rail Application, Marine Application, Industrial Application, Underground Application, Multi-Purpose Application
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Standards IEC 60684-3-214, IEC 60684-3-246 IEC 60684-3-247, HD631.2
  • Product Availability Worldwide
  • Packaging Method Pieces
  • Product Use Wrap-Around, Sealed Cable Tap Splice
  • Other Colors Available No
159659-000 Power Cable Wraps  1
HD CENELEC 631.2 IEC 60684-3-214 IEC 60684-3-246 IEC 60684-3-247
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Shrink Ratio > 2.5:1
  • Product Family RFSM
  • Component Design Heat Shrink
  • Coating Style Inline
  • Flexibility Semi-Rigid
  • Color Black, Outer Layer with Thermo-Indicative Paint
  • Mechanical Reinforcement Fiber-Reinforced
  • Application Diameter (Max) 185
  • Application Diameter (Min) 70
  • Wall Thickness Medium
  • Recovered Wall Thickness (Max) 4.5
  • Cut Length 1500
  • Flammability Non-Flame-Retardant
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Application Cable Jacketing, Cable Repair, Rejacketing/Outer Protection on Joints/Splices, Insulation & Protection, Rail Application, Marine Application, Industrial Application, Underground Application, Multi-Purpose Application
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Standards IEC 60684-3-214, IEC 60684-3-246 IEC 60684-3-247, HD631.2
  • Product Availability Worldwide
  • Packaging Method Pieces
  • Product Use Wrap-Around, Sealed Cable Tap Splice
  • Other Colors Available No
186312-000 Power Cable Wraps  1
HD CENELEC 631.2 IEC 60684-3-214 IEC 60684-3-246 IEC 60684-3-247
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Shrink Ratio > 2.5:1
  • Product Family RFSM
  • Component Design Heat Shrink
  • Coating Style Inline
  • Flexibility Semi-Rigid
  • Color Black, Outer Layer with Thermo-Indicative Paint
  • Mechanical Reinforcement Fiber-Reinforced
  • Application Diameter (Max) 86
  • Application Diameter (Min) 33
  • Wall Thickness Medium
  • Recovered Wall Thickness (Max) 4.5
  • Cut Length 750
  • Flammability Non-Flame-Retardant
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Application Cable Jacketing, Cable Repair, Rejacketing/Outer Protection on Joints/Splices, Insulation & Protection, Rail Application, Marine Application, Industrial Application, Underground Application, Multi-Purpose Application
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Standards IEC 60684-3-214, IEC 60684-3-246 IEC 60684-3-247, HD631.2
  • Product Availability Worldwide
  • Packaging Method Pieces
  • Product Use Wrap-Around, Sealed Cable Tap Splice
  • Other Colors Available No
326257-000 Power Cable Wraps  1
MSHA Approved
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Product Family MRS
  • Component Design Heat Shrink
  • Coating Style Inline
  • Voltage Rating 2
  • Flexibility Semi-Flexible
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Max) 41
  • Application Diameter (Min) 25
  • Wall Thickness Medium
  • Sleeve Length 610
  • Flammability Yes
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • UV-Stabilized Yes
  • Mechanical Resistance Abrasion Resistant
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Application Cable Jacketing, Cable Repair, Rejacketing/Outer Protection on Joints/Splices, Insulation & Protection, Rail Application, Marine Application, Industrial Application, Underground Application, Multi-Purpose Application
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Flame-Retardant
  • UL Rating No
  • Standards MSHA Approved
  • CSA Certified No
  • Product Availability Worldwide
  • Standard Pack 10
  • Product Use Power cables, Telecom cables, Joints/Splices, Mechanical protection & outer sealing on LV/MV/HV applications on flexible cables (e.g. for mining)
347861-000 Power Cable Wraps  1
MSHA Approved
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Product Family MRS
  • Component Design Heat Shrink
  • Coating Style Inline
  • Voltage Rating 2
  • Flexibility Semi-Flexible
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Max) 89
  • Application Diameter (Min) 58
  • Wall Thickness Medium
  • Sleeve Length 762
  • Flammability Yes
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • UV-Stabilized Yes
  • Mechanical Resistance Abrasion Resistant
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Application Cable Jacketing, Cable Repair, Rejacketing/Outer Protection on Joints/Splices, Insulation & Protection, Rail Application, Marine Application, Industrial Application, Underground Application, Multi-Purpose Application
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Flame-Retardant
  • UL Rating No
  • Standards MSHA Approved
  • CSA Certified No
  • Product Availability Worldwide
  • Standard Pack 10
  • Product Use Power cables, Telecom cables, Joints/Splices, Mechanical protection & outer sealing on LV/MV/HV applications on flexible cables (e.g. for mining)
407236-000 Power Cable Wraps  1
MSHA Approved
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Product Family MRS
  • Component Design Heat Shrink
  • Coating Style Inline
  • Voltage Rating 2
  • Flexibility Semi-Flexible
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Max) 58
  • Application Diameter (Min) 41
  • Wall Thickness Medium
  • Sleeve Length 762
  • Flammability Yes
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • UV-Stabilized Yes
  • Mechanical Resistance Abrasion Resistant
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Application Cable Jacketing, Cable Repair, Rejacketing/Outer Protection on Joints/Splices, Insulation & Protection, Rail Application, Marine Application, Industrial Application, Underground Application, Multi-Purpose Application
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Flame-Retardant
  • UL Rating No
  • Standards MSHA Approved
  • CSA Certified No
  • Product Availability Worldwide
  • Standard Pack 10
  • Product Use Power cables, Telecom cables, Joints/Splices, Mechanical protection & outer sealing on LV/MV/HV applications on flexible cables (e.g. for mining)
070003-000 Power Cable Wraps  1
HD CENELEC 631.2 IEC 60684-3-214 IEC 60684-3-246 IEC 60684-3-247
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Shrink Ratio > 2.5:1
  • Product Family RFSM
  • Component Design Heat Shrink
  • Coating Style Inline
  • Flexibility Semi-Rigid
  • Color Black, Outer Layer with Thermo-Indicative Paint
  • Mechanical Reinforcement Fiber-Reinforced
  • Application Diameter (Max) 150
  • Application Diameter (Min) 60
  • Wall Thickness Medium
  • Recovered Wall Thickness (Max) 4.5
  • Cut Length 1500
  • Flammability Non-Flame-Retardant
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Application Cable Jacketing, Cable Repair, Rejacketing/Outer Protection on Joints/Splices, Insulation & Protection, Rail Application, Marine Application, Industrial Application, Underground Application, Multi-Purpose Application
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Standards IEC 60684-3-214, IEC 60684-3-246 IEC 60684-3-247, HD631.2
  • Product Availability Worldwide
  • Packaging Method Pieces
  • Product Use Wrap-Around, Sealed Cable Tap Splice
  • Other Colors Available No
167019-000 Power Cable Wraps  1
MSHA Approved
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Product Family MRS
  • Component Design Heat Shrink
  • Coating Style Inline
  • Voltage Rating 2
  • Flexibility Semi-Flexible
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Max) 58
  • Application Diameter (Min) 41
  • Wall Thickness Medium
  • Sleeve Length 610
  • Flammability Yes
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • UV-Stabilized Yes
  • Mechanical Resistance Abrasion Resistant
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Application Cable Jacketing, Cable Repair, Rejacketing/Outer Protection on Joints/Splices, Insulation & Protection, Rail Application, Marine Application, Industrial Application, Underground Application, Multi-Purpose Application
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Flame-Retardant
  • UL Rating No
  • Standards MSHA Approved
  • CSA Certified No
  • Product Availability Worldwide
  • Standard Pack 10
  • Product Use Power cables, Telecom cables, Joints/Splices, Mechanical protection & outer sealing on LV/MV/HV applications on flexible cables (e.g. for mining)
570500-000 Power Cable Wraps  1
MSHA Approved
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Product Family MRS
  • Component Design Heat Shrink
  • Coating Style Inline
  • Voltage Rating 2
  • Flexibility Semi-Flexible
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Max) 41
  • Application Diameter (Min) 25
  • Wall Thickness Medium
  • Sleeve Length 254
  • Flammability Yes
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • UV-Stabilized Yes
  • Mechanical Resistance Abrasion Resistant
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Application Cable Jacketing, Cable Repair, Rejacketing/Outer Protection on Joints/Splices, Insulation & Protection, Rail Application, Marine Application, Industrial Application, Underground Application, Multi-Purpose Application
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Flame-Retardant
  • UL Rating No
  • Standards MSHA Approved
  • CSA Certified No
  • Product Availability Worldwide
  • Standard Pack 20
  • Product Use Power cables, Telecom cables, Joints/Splices, Mechanical protection & outer sealing on LV/MV/HV applications on flexible cables (e.g. for mining)
029557-000 Power Cable Wraps  1
HD CENELEC 631.2 IEC 60684-3-214 IEC 60684-3-246 IEC 60684-3-247
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Shrink Ratio > 2.5:1
  • Product Family RFSM
  • Component Design Heat Shrink
  • Coating Style Inline
  • Flexibility Semi-Rigid
  • Color Black, Outer Layer with Thermo-Indicative Paint
  • Mechanical Reinforcement Fiber-Reinforced
  • Application Diameter (Max) 113
  • Application Diameter (Min) 44
  • Wall Thickness Medium
  • Recovered Wall Thickness (Max) 4.5
  • Cut Length 500
  • Flammability Non-Flame-Retardant
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Application Cable Jacketing, Cable Repair, Rejacketing/Outer Protection on Joints/Splices, Insulation & Protection, Rail Application, Marine Application, Industrial Application, Underground Application, Multi-Purpose Application
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Standards IEC 60684-3-214, IEC 60684-3-246 IEC 60684-3-247, HD631.2
  • Product Availability Worldwide
  • Packaging Method Pieces
  • Product Use Wrap-Around, Sealed Cable Tap Splice
  • Other Colors Available No
059455-000 Power Cable Wraps  1
HD CENELEC 631.2 IEC 60684-3-214 IEC 60684-3-246 IEC 60684-3-247
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Shrink Ratio > 2.5:1
  • Product Family RFSM
  • Component Design Heat Shrink
  • Coating Style Inline
  • Flexibility Semi-Rigid
  • Color Black, Outer Layer with Thermo-Indicative Paint
  • Mechanical Reinforcement Fiber-Reinforced
  • Application Diameter (Max) 150
  • Application Diameter (Min) 60
  • Wall Thickness Medium
  • Recovered Wall Thickness (Max) 4.5
  • Cut Length 750
  • Flammability Non-Flame-Retardant
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Application Cable Jacketing, Cable Repair, Rejacketing/Outer Protection on Joints/Splices, Insulation & Protection, Rail Application, Marine Application, Industrial Application, Underground Application, Multi-Purpose Application
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Standards IEC 60684-3-214, IEC 60684-3-246 IEC 60684-3-247, HD631.2
  • Product Availability Worldwide
  • Packaging Method Pieces
  • Product Use Wrap-Around, Sealed Cable Tap Splice
  • Other Colors Available No
131687-000 Power Cable Wraps  1
HD CENELEC 631.2 IEC 60684-3-214 IEC 60684-3-246 IEC 60684-3-247
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Shrink Ratio > 2.5:1
  • Product Family RFSM
  • Component Design Heat Shrink
  • Coating Style Inline
  • Flexibility Semi-Rigid
  • Color Black, Outer Layer with Thermo-Indicative Paint
  • Mechanical Reinforcement Fiber-Reinforced
  • Application Diameter (Max) 113
  • Application Diameter (Min) 44
  • Wall Thickness Medium
  • Recovered Wall Thickness (Max) 4.5
  • Cut Length 1250
  • Flammability Non-Flame-Retardant
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Application Cable Jacketing, Cable Repair, Rejacketing/Outer Protection on Joints/Splices, Insulation & Protection, Rail Application, Marine Application, Industrial Application, Underground Application, Multi-Purpose Application
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Standards IEC 60684-3-214, IEC 60684-3-246 IEC 60684-3-247, HD631.2
  • Product Availability Worldwide
  • Packaging Method Pieces
  • Product Use Wrap-Around, Sealed Cable Tap Splice
  • Other Colors Available No
198699-000 Power Cable Wraps  1
HD CENELEC 631.2 IEC 60684-3-214 IEC 60684-3-246 IEC 60684-3-247
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Shrink Ratio > 2.5:1
  • Product Family RFSM
  • Component Design Heat Shrink
  • Coating Style Inline
  • Flexibility Semi-Rigid
  • Color Black, Outer Layer with Thermo-Indicative Paint
  • Mechanical Reinforcement Fiber-Reinforced
  • Application Diameter (Max) 60
  • Application Diameter (Min) 22
  • Wall Thickness Medium
  • Recovered Wall Thickness (Max) 4.5
  • Cut Length 1000
  • Flammability Non-Flame-Retardant
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Application Cable Jacketing, Cable Repair, Rejacketing/Outer Protection on Joints/Splices, Insulation & Protection, Rail Application, Marine Application, Industrial Application, Underground Application, Multi-Purpose Application
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Standards IEC 60684-3-214, IEC 60684-3-246 IEC 60684-3-247, HD631.2
  • Product Availability Worldwide
  • Packaging Method Pieces
  • Product Use Wrap-Around, Sealed Cable Tap Splice
  • Other Colors Available No
253801-000 Power Cable Wraps  1
HD CENELEC 631.2 IEC 60684-3-214 IEC 60684-3-246 IEC 60684-3-247
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Shrink Ratio > 2.5:1
  • Product Family RFSM
  • Component Design Heat Shrink
  • Coating Style Inline
  • Flexibility Semi-Rigid
  • Color Black, Outer Layer with Thermo-Indicative Paint
  • Mechanical Reinforcement Fiber-Reinforced
  • Application Diameter (Max) 60
  • Application Diameter (Min) 22
  • Wall Thickness Medium
  • Recovered Wall Thickness (Max) 4.5
  • Cut Length 750
  • Flammability Non-Flame-Retardant
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Application Cable Jacketing, Cable Repair, Rejacketing/Outer Protection on Joints/Splices, Insulation & Protection, Rail Application, Marine Application, Industrial Application, Underground Application, Multi-Purpose Application
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Standards IEC 60684-3-214, IEC 60684-3-246 IEC 60684-3-247, HD631.2
  • Product Availability Worldwide
  • Packaging Method Pieces
  • Product Use Wrap-Around, Sealed Cable Tap Splice
  • Other Colors Available No
278829-000 Power Cable Wraps  1
HD CENELEC 631.2
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Shrink Ratio > 2.5:1
  • Product Family MRSM
  • Component Design Heat Shrink
  • Coating Style Inline
  • Flexibility Semi-Flexible
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Max) 89
  • Application Diameter (Min) 58
  • Wall Thickness Medium
  • Recovered Wall Thickness (Max) 1.8
  • Expanded Inside Diameter (Min) 100
  • Recovered Inside Diameter (Max) 51
  • Cut Length 600
  • Flammability Flame-Retardant
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Application Cable Jacketing, Cable Repair, Rejacketing/Outer Protection on Joints/Splices, Insulation & Protection, Rail Application, Marine Application, Industrial Application, Underground Application, Multi-Purpose Application
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Flame-Retardant
  • Standards IEC 60684-3-216, IEC 60684-3-248 HD631.2
  • Product Availability Worldwide
  • Packaging Method Pieces
  • Product Use Power cables, Telecom cables, Joints/Splices, Mechanical protection & outer sealing on LV/MV/HV applications on flexible cables (e.g. for mining)
  • Other Colors Available No
295069-000 Power Cable Wraps  1
HD CENELEC 631.2
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Shrink Ratio > 2.5:1
  • Product Family MRSM
  • Component Design Heat Shrink
  • Coating Style Inline
  • Flexibility Semi-Flexible
  • Color Black
  • Mechanical Reinforcement No
  • Application Diameter (Max) 40
  • Application Diameter (Min) 25
  • Wall Thickness Medium
  • Recovered Wall Thickness (Max) 1.8
  • Expanded Inside Diameter (Min) 50
  • Recovered Inside Diameter (Max) 23
  • Cut Length 600
  • Flammability Flame-Retardant
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Application Cable Jacketing, Cable Repair, Rejacketing/Outer Protection on Joints/Splices, Insulation & Protection, Rail Application, Marine Application, Industrial Application, Underground Application, Multi-Purpose Application
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Flame-Retardant
  • Standards IEC 60684-3-216, IEC 60684-3-248 HD631.2
  • Product Availability Worldwide
  • Packaging Method Pieces
  • Product Use Power cables, Telecom cables, Joints/Splices, Mechanical protection & outer sealing on LV/MV/HV applications on flexible cables (e.g. for mining)
  • Other Colors Available No
310667-000 Power Cable Wraps  1
HD CENELEC 631.2 IEC 60684-3-214 IEC 60684-3-246 IEC 60684-3-247
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Shrink Ratio > 2.5:1
  • Product Family RFSM
  • Component Design Heat Shrink
  • Coating Style Inline
  • Flexibility Semi-Rigid
  • Color Black, Outer Layer with Thermo-Indicative Paint
  • Mechanical Reinforcement Fiber-Reinforced
  • Application Diameter (Max) 86
  • Application Diameter (Min) 33
  • Wall Thickness Medium
  • Recovered Wall Thickness (Max) 4.5
  • Cut Length 500
  • Flammability Non-Flame-Retardant
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • UV-Stabilized Yes
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Low Smoke Emission Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Application Cable Jacketing, Cable Repair, Rejacketing/Outer Protection on Joints/Splices, Insulation & Protection, Rail Application, Marine Application, Industrial Application, Underground Application, Multi-Purpose Application
  • Marine-Offshore-Shipbuilding Certified No
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Standards IEC 60684-3-214, IEC 60684-3-246 IEC 60684-3-247, HD631.2
  • Product Availability Worldwide
  • Packaging Method Pieces
  • Product Use Wrap-Around, Sealed Cable Tap Splice
  • Other Colors Available No
327309-000 Power Cable Wraps  1
  • Material System Crosslinked Polyolefin
  • Technology Heat Shrink
  • Product Type Heat Shrink Wrap-Around
  • Adhesive Coating Yes
  • Wall Style (Excluding Adhesive) Single
  • Shrink Ratio > 2.5:1
  • Product Family CFSM
  • Component Design Heat Shrink
  • Coating Style Inline
  • Flexibility Semi-Rigid
  • Color Black, Supplied with Green Thermo-Sensitive Paint
  • Mechanical Reinforcement Fabric (Woven Textile) Reinforced
  • Application Diameter (Max) 75
  • Application Diameter (Min) 15
  • Wall Thickness Medium
  • Recovered Wall Thickness (Max) 1.5
  • Sleeve Length 700
  • Cut Length 700
  • Flammability Non-Flame-Retardant
  • Environmental Resistance Moisture, Weathering, Rain, Salt Water, Contaminated Water …
  • Chemical Resistance Transformer Oil & Hydrocarbons (Both, Depending on Type, Conditions & Exposure Time)
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Application Cable Jacketing, Cable Repair, Rejacketing/Outer Protection on Joints/Splices, Insulation & Protection
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Standards IEC 60684-3-214, IEC 60684-3-246 IEC 60684-3-247, HD631.2
  • Product Availability Worldwide
  • Packaging Method Pieces
  • Product Use Cable Jacket Repair, Protection of Joints for Cables with outer metallic screen or sheath
  • Other Colors Available No