Please review product documents or contact us for the latest agency approval information.
Product Type Features
-
Wire/Cladding Type
26AWG Fluoropolymer Insulated, ESCC 390101203 | 26AWG Polyimide Insulated, ESCC 390100124
-
NTC Probe Type
Space Qualified NTC Thermistors
-
Sensor Package
ESAP-ESA PROBE
Configuration Features
-
Electrical Connection
2 Pin
Electrical Characteristics
-
β-Value(25/85) (K)
3499 | 3664 | 4261
Mechanical Attachment
-
Wire Length (mm)
281 | 305 | 381 | 525
Usage Conditions
-
Operating Temperature Range (°C)
-60 – 160 | -40 – 125 | 25 – 160
-
T_ref for Resistance (°C)
-60 | -40 | -20 | 0 | 25 | 50 | 70 | 100 | 125 | 140 | 160
-
Resistance (at 25°C) (kΩ)
2 | 10 | 15 | 100
-
Tolerance Resistance (%)
± .8 @ 0 °C | ± 1.57 @ 0 °C | ± 1.75 @ 25 °C | ± 1 @ 0 °C | ± 2 @ 0 °C
Reference Number
-
TE Internal Number
CAT-NTC0049