PRODUCT
- Main Insulation Piercing Connectors CAT-IPC-P3X-P4X
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) Yes
- Piercing Blade Base Material Tinned Copper
- Piercing & Stripping (Opposite Sides) No
- Stripping (Main & Tap) No
- Product Family Insulation Piercing Connector
- Number of Bolts 2
- Insulating Connector Voltage Class ≤ 1
- Conductor Insulation XLPE
- Connection Under Load (90A Max) No
- Current Rating 550
- Product Weight 342
- Shear Head Breaking Torque 18
- Shear Head System Yes
- Conductor Range (Main) 25 – 120
- Conductor Range (Tap) 25 – 120
- Wire Insulation Thickness (Max) 2
- Shear Head Size (Across Flats) 13
- Installation Temperature Range -20 – 55
- Overhead Yes
- Application Type Main-to-Main Lines
- Standard Reference EN 50483-4 / NFC 33 020
- Insulating Connector Product Availability AMERICAS
- Minimum Order Quantity 25
- Minimum Packaging Unit 25

PRODUCT
- Service Insulation Piercing Connectors CAT-IPC-P2X95-MK2
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) Yes
- Piercing Blade Base Material Aluminum Alloy
- Piercing & Stripping (Opposite Sides) No
- Stripping (Main & Tap) No
- Product Family Insulation Piercing Connector
- Number of Bolts 1
- Insulating Connector Voltage Class ≤ 1
- Conductor Insulation XLPE
- Connection Under Load (90A Max) No
- Current Rating 100
- Product Weight 118
- Shear Head Breaking Torque 11
- Shear Head System Yes
- Conductor Range (Main) 16 – 95
- Conductor Range (Tap) 4 – 35 (50)
- Wire Insulation Thickness (Max) 2
- Shear Head Size (Across Flats) 13
- Installation Temperature Range -20 – 55
- Overhead Yes
- Application Type Insulated Service Line
- Standard Reference EN 50483-4 / NFC 33 020
- Insulating Connector Product Availability AMERICAS
- Minimum Order Quantity 50
- Minimum Packaging Unit 50

PRODUCT
- KZEP 4/0 1-708052-1
EN 50483-4
NFC 33 041
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) Yes
- Piercing Blade Base Material Tinned Copper
- Piercing & Stripping (Opposite Sides) No
- Stripping (Main & Tap) No
- Product Family Insulation Piercing Connector
- Number of Bolts 1
- Insulating Connector Voltage Class 1
- Conductor Insulation XLPE
- Connection Under Load (90A Max) Yes
- Current Rating 63
- Product Weight 54
- Shear Head Breaking Torque 7
- Shear Head System Yes
- Conductor Range (Main) 13.3 – 107
- Conductor Range (Tap) 2.08 – 5.26
- Wire Insulation Thickness (Max) 1.8
- Shear Head Size (Across Flats) 10
- Installation Temperature Range -20 – 55
- Overhead Yes
- Application Type Street Lighting
- Standard Reference ANSI C119.5
- Insulating Connector Product Availability AMERICAS
- Minimum Order Quantity 50
- Minimum Packaging Unit 50

PRODUCT
- P3X4/0 1727742-1
EN 50483-4
NFC 33 041
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) Yes
- Piercing Blade Base Material Tinned Copper
- Piercing & Stripping (Opposite Sides) No
- Stripping (Main & Tap) No
- Product Family Insulation Piercing Connector
- Number of Bolts 1
- Insulating Connector Voltage Class 1
- Conductor Insulation XLPE
- Connection Under Load (90A Max) No
- Current Rating 350
- Product Weight 151
- Shear Head Breaking Torque 18
- Shear Head System Yes
- Conductor Range (Main) 21.2 – 107
- Conductor Range (Tap) 21.2 – 107
- Wire Insulation Thickness (Max) 2.2
- Shear Head Size (Across Flats) 14.2
- Installation Temperature Range -20 – 55
- Overhead Yes
- Application Type Main to Main Connection
- Standard Reference ANSI C119.5
- Insulating Connector Product Availability AMERICAS
- Minimum Order Quantity 50
- Minimum Packaging Unit 50

PRODUCT
- KZ2T-25 CBS 1018566-1
EN 50483-4
NFC 33 041
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) Yes
- Piercing Blade Base Material Aluminum Alloy
- Piercing & Stripping (Opposite Sides) No
- Stripping (Main & Tap) No
- Product Family Insulation Piercing Connector
- Number of Bolts 1
- Insulating Connector Voltage Class 1
- Conductor Insulation XLPE
- Connection Under Load (90A Max) No
- Current Rating 100
- Product Weight 220
- Shear Head Breaking Torque 11
- Shear Head System Yes
- Conductor Range (Main) 16 – 25
- Conductor Range (Tap) 4 – 35 (50)
- Wire Insulation Thickness (Max) 2
- Shear Head Size (Across Flats) 13
- Installation Temperature Range -20 – 55
- Overhead Yes
- Application Type Earthing Connection
- Standard Reference NFC 33 020 / EN 50483-4
- Insulating Connector Product Availability Worldwide
- Minimum Order Quantity 10
- Minimum Packaging Unit 10

PRODUCT
- KZ2T-70 CBS 1018566-2
EN 50483-4
NFC 33 041
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) Yes
- Piercing Blade Base Material Aluminum Alloy
- Piercing & Stripping (Opposite Sides) No
- Stripping (Main & Tap) No
- Product Family Insulation Piercing Connector
- Number of Bolts 1
- Insulating Connector Voltage Class 1
- Conductor Insulation XLPE
- Connection Under Load (90A Max) No
- Current Rating 100
- Product Weight 217
- Shear Head Breaking Torque 11
- Shear Head System Yes
- Conductor Range (Main) 35 – 70
- Conductor Range (Tap) 4 – 35 (50)
- Wire Insulation Thickness (Max) 2
- Shear Head Size (Across Flats) 13
- Installation Temperature Range -20 – 55
- Overhead Yes
- Application Type Earthing Connection
- Standard Reference NFC 33 020 / EN 50483-4
- Insulating Connector Product Availability Worldwide
- Minimum Order Quantity 10
- Minimum Packaging Unit 10

PRODUCT
- KZ2T-150 CBS 1018566-3
EN 50483-4
NFC 33 041
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) Yes
- Piercing Blade Base Material Aluminum Alloy
- Piercing & Stripping (Opposite Sides) No
- Stripping (Main & Tap) No
- Product Family Insulation Piercing Connector
- Number of Bolts 1
- Insulating Connector Voltage Class 1
- Conductor Insulation XLPE
- Connection Under Load (90A Max) No
- Current Rating 100
- Product Weight 220
- Shear Head Breaking Torque 11
- Shear Head System Yes
- Conductor Range (Main) 50 – 150
- Conductor Range (Tap) 6 – 35 (50)
- Wire Insulation Thickness (Max) 2
- Shear Head Size (Across Flats) 13
- Installation Temperature Range -20 – 55
- Overhead Yes
- Application Type Earthing Connection
- Standard Reference NFC 33 020 / EN 50483-4
- Insulating Connector Product Availability Worldwide
- Minimum Order Quantity 10
- Minimum Packaging Unit 10

PRODUCT
- PMCC 1018731-2
EN 50483-4
NFC 33 041
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) No
- Piercing & Stripping (Opposite Sides) No
- Stripping (Main & Tap) No
- Product Family Insulation Piercing Connector
- Insulating Connector Voltage Class 1
- Connection Under Load (90A Max) No
- Product Weight 78
- Installation Temperature Range -20 – 55
- Overhead Yes
- Application Type Earthing Connection
- Standard Reference NFC 33 020 / EN 50483-4
- Insulating Connector Product Availability Worldwide
- Minimum Order Quantity 10
- Minimum Packaging Unit 10

PRODUCT
- KZ4-150 CHINE EXPORT 1351230-2
EN 50483-4
NFC 33 041
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) Yes
- Piercing Blade Base Material Tinned Copper
- Piercing & Stripping (Opposite Sides) No
- Stripping (Main & Tap) No
- Product Family Insulation Piercing Connector
- Number of Bolts 1
- Insulating Connector Voltage Class 1
- Conductor Insulation XLPE
- Connection Under Load (90A Max) No
- Current Rating 550
- Product Weight 229
- Shear Head Breaking Torque 22
- Shear Head System Yes
- Conductor Range (Main) 50 – 150
- Conductor Range (Tap) 50 – 150
- Wire Insulation Thickness (Max) 2.2
- Shear Head Size (Across Flats) 13
- Installation Temperature Range -20 – 55
- Overhead Yes
- Application Type Earthing Connection
- Standard Reference NFC 33 020 / EN 50483-4
- Insulating Connector Product Availability Worldwide
- Minimum Order Quantity 50
- Minimum Packaging Unit 50

PRODUCT
- DZ6 UL-F CHINA-N 1351231-2
EN 50483-4
GB 2317
GB 9327
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) Yes
- Piercing Blade Base Material Tinned Copper
- Piercing & Stripping (Opposite Sides) No
- Stripping (Main & Tap) No
- Product Family Insulation Piercing Connector
- Number of Bolts 1
- Insulating Connector Voltage Class ≤ 1
- Conductor Insulation XLPE
- Connection Under Load (90A Max) No
- Current Rating 239
- Shear Head Breaking Torque 36 – 44
- Shear Head System Yes
- Conductor Range (Main) 120 – 240
- Conductor Range (Tap) 25 – 120
- Wire Insulation Thickness (Max) 2
- Shear Head Size (Across Flats) 17
- Installation Temperature Range -20 – 55
- Overhead Yes
- Application Type Insulated Service Line
- Standard Reference EN 50483-4 / GB 9327 / GB2317
- Insulating Connector Product Availability China
- Minimum Order Quantity 50
- Minimum Packaging Unit 120

PRODUCT
- BPC P50 1780816-1
NFC 33 020
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) Yes
- Piercing & Stripping (Opposite Sides) No
- Stripping (Main & Tap) No
- Product Family Bolted Pre-Insulated Sleeve
- Insulating Connector Voltage Class ≤ 1
- Conductor Insulation XLPE
- Connection Under Load (90A Max) No
- Product Weight 85
- Shear Head Breaking Torque 10
- Shear Head System Yes
- Conductor Range (Al/Cu) 4 – 50
- Wire Insulation Thickness (Max) 2
- Shear Head Size (Across Flats) 13
- Overhead Yes
- Application Type Insulated Service Line
- Standard Reference NFC 33 020
- Insulating Connector Product Availability AMERICAS
- Minimum Order Quantity 10
- Minimum Packaging Unit 10

EN 50483-4
GB 2317
GB 9327
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) Yes
- Piercing Blade Base Material Tinned Copper
- Piercing & Stripping (Opposite Sides) No
- Stripping (Main & Tap) No
- Product Family Insulation Piercing Connector
- Number of Bolts 1
- Insulating Connector Voltage Class ≤ 12
- Conductor Insulation XLPE
- Connection Under Load (90A Max) No
- Current Rating 320
- Shear Head Breaking Torque 19.8 – 24.2
- Shear Head System Yes
- Conductor Range (Main) 16 – 95
- Conductor Range (Tap) 16 – 70
- Shear Head Size (Across Flats) 13
- Installation Temperature Range -20 – 55
- Overhead Yes
- Application Type Insulated Service Line
- Standard Reference EN 50483-4 / GB 9327 / GB2317
- Insulating Connector Product Availability China
- Minimum Order Quantity 12
- Minimum Packaging Unit 150

PRODUCT
- MV240-95 2019862-1
EN 50483-4
GB 2317
GB 9327
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) Yes
- Piercing Blade Base Material Tinned Copper
- Piercing & Stripping (Opposite Sides) No
- Stripping (Main & Tap) No
- Product Family Insulation Piercing Connector
- Number of Bolts 1
- Insulating Connector Voltage Class ≤ 12
- Conductor Insulation XLPE
- Shear Head Breaking Torque 19.8 – 24.2
- Shear Head System Yes
- Conductor Range (Main) 95 – 240
- Conductor Range (Tap) 35 – 95
- Shear Head Size (Across Flats) 13
- Installation Temperature Range -20 – 55
- Overhead Yes
- Application Type Insulated Service Line
- Standard Reference EN 50483-4 / GB 9327 / GB2317
- Insulating Connector Product Availability China
- Minimum Order Quantity 12
- Minimum Packaging Unit 48

PRODUCT
- MV240-185 2037544-1
EN 50483-4
GB 2317
GB 9327
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) Yes
- Piercing Blade Base Material Tinned Copper
- Piercing & Stripping (Opposite Sides) No
- Stripping (Main & Tap) No
- Product Family Insulation Piercing Connector
- Number of Bolts 1
- Insulating Connector Voltage Class ≤ 12
- Conductor Insulation XLPE
- Shear Head Breaking Torque 36 – 44
- Shear Head System Yes
- Conductor Range (Main) 120 – 240
- Conductor Range (Tap) 95 – 185
- Shear Head Size (Across Flats) 17
- Installation Temperature Range -20 – 55
- Overhead Yes
- Application Type Insulated Service Line
- Standard Reference EN 50483-4 / GB 9327 / GB2317
- Insulating Connector Product Availability China
- Minimum Order Quantity 12
- Minimum Packaging Unit 48

PRODUCT
- MV300-240 2062463-1
EN 50483-4
GB 2317
GB 9327
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) Yes
- Piercing Blade Base Material Tinned Copper
- Piercing & Stripping (Opposite Sides) No
- Stripping (Main & Tap) No
- Product Family Insulation Piercing Connector
- Number of Bolts 2
- Insulating Connector Voltage Class ≤ 12
- Conductor Insulation XLPE
- Shear Head Breaking Torque 36 – 44
- Shear Head System Yes
- Conductor Range (Main) 185 – 300
- Conductor Range (Tap) 150 – 240
- Shear Head Size (Across Flats) 17
- Installation Temperature Range -20 – 55
- Overhead Yes
- Application Type Insulated Service Line
- Standard Reference EN 50483-4 / GB 9327 / GB2317
- Insulating Connector Product Availability China
- Minimum Order Quantity 12
- Minimum Packaging Unit 48

PRODUCT
- KZ5-240 D, China 2084351-1
EN 50483-4
GB 2317
GB 9327
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) Yes
- Piercing Blade Base Material Tinned Copper
- Piercing & Stripping (Opposite Sides) No
- Stripping (Main & Tap) No
- Product Family Insulation Piercing Connector
- Number of Bolts 2
- Insulating Connector Voltage Class ≤ 1
- Conductor Insulation XLPE
- Current Rating 712
- Shear Head Breaking Torque 36 – 44
- Shear Head System Yes
- Conductor Range (Main) 0 – 0000
- Conductor Range (Tap) 0000
- Conductor Range (Main) 150 – 240
- Conductor Range (Tap) 150 – 240
- Shear Head Size (Across Flats) 17
- Wire Insulation Thickness (Max) 2
- Installation Temperature Range -20 – 55
- Overhead Yes
- Application Type Main-to-Main Lines
- Standard Reference EN 50483-4 / GB 9327 / GB2317
- Insulating Connector Product Availability China
- Minimum Order Quantity 25
- Minimum Packaging Unit 150

EN 50483-4
GB 2317
GB 9327
NFC 33 020
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) Yes
- Piercing Blade Base Material Tinned Copper
- Piercing & Stripping (Opposite Sides) No
- Stripping (Main & Tap) No
- Product Family Insulation Piercing Connector
- Number of Bolts 1
- Insulating Connector Voltage Class ≤ 1
- Conductor Insulation XLPE
- Connection Under Load (90A Max) No
- Current Rating 138
- Product Weight 112
- Shear Head Breaking Torque 9.9 – 12.1
- Shear Head System Yes
- Conductor Range (Main) 16 – 95
- Conductor Range (Tap) 4 – 35 (50)
- Wire Insulation Thickness (Max) 2
- Shear Head Size (Across Flats) 13
- Installation Temperature Range -20 – 55
- Overhead Yes
- Application Type Insulated Service Line
- Standard Reference EN 50483-4 / GB 9327 / GB2317 / NFC 33 020
- Insulating Connector Product Availability China
- Minimum Order Quantity 50
- Minimum Packaging Unit 150

EN 50483-4
GB 2317
GB 9327
NFC 33 020
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) Yes
- Piercing Blade Base Material Aluminum Alloy
- Piercing & Stripping (Opposite Sides) No
- Stripping (Main & Tap) No
- Product Family Insulation Piercing Connector
- Number of Bolts 1
- Insulating Connector Voltage Class ≤ 1
- Conductor Insulation XLPE
- Connection Under Load (90A Max) No
- Current Rating 138
- Product Weight 108
- Shear Head Breaking Torque 9.9 – 12.1
- Shear Head System Yes
- Conductor Range (Main) 16 – 95
- Conductor Range (Tap) 4 – 35 (50)
- Wire Insulation Thickness (Max) 2
- Shear Head Size (Across Flats) 13
- Installation Temperature Range -20 – 55
- Overhead Yes
- Application Type Insulated Service Line
- Standard Reference EN 50483-4 / GB 9327 / GB2317 / NFC 33 020
- Insulating Connector Product Availability China
- Minimum Order Quantity 50
- Minimum Packaging Unit 150

EN 50483-4
GB 2317
GB 9327
NFC 33 020
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) Yes
- Piercing Blade Base Material Aluminum Alloy
- Piercing & Stripping (Opposite Sides) No
- Stripping (Main & Tap) No
- Product Family Insulation Piercing Connector
- Number of Bolts 1
- Insulating Connector Voltage Class ≤ 1
- Conductor Insulation XLPE
- Connection Under Load (90A Max) No
- Current Rating 138
- Product Weight 118
- Shear Head Breaking Torque 9.9 – 12.1
- Shear Head System Yes
- Conductor Range (Main) 50 – 150
- Conductor Range (Tap) 6 – 35 (50)
- Wire Insulation Thickness (Max) 2
- Shear Head Size (Across Flats) 13
- Installation Temperature Range -20 – 55
- Overhead Yes
- Application Type Insulated Service Line
- Standard Reference EN 50483-4 / GB 9327 / GB2317 / NFC 33 020
- Insulating Connector Product Availability China
- Minimum Order Quantity 50
- Minimum Packaging Unit 150

PRODUCT
- P3B120 2107862-1
EN 50483-4
- Insulating Connector Technology Piercing
- Piercing (Main & Tap) No
- Piercing Blade Base Material Tinned Copper
- Piercing & Stripping (Opposite Sides) Yes
- Stripping (Main & Tap) No
- Product Family Transition Connector LV Bare to LV ABC
- Number of Bolts 1
- Insulating Connector Voltage Class ≤ 1
- Conductor Insulation XLPE
- Connection Under Load (90A Max) No
- Current Rating 350
- Product Weight 170
- Shear Head Breaking Torque 18
- Shear Head System Yes
- Conductor Range (Main) 7 – 120 (150)
- Conductor Range (Tap) 25 – 95
- Wire Insulation Thickness (Max) 2
- Shear Head Size (Across Flats) 13
- Installation Temperature Range -20 – 55
- Overhead Yes
- Application Type Main-to-Main Lines
- Standard Reference EN 50483-4
- Insulating Connector Product Availability AMERICAS
- Minimum Order Quantity 50
- Minimum Packaging Unit 50