CAT-SCH691-R819B Power Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Power Relays
  1. PCB Power Relay: Bystable, Polarized CAT-SCH691-R819B
active
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 16
  • Coil Magnetic System Bistable, 1 Coil, Polarized
  • Coil Power Rating Class 600 – 800
  • Coil Power Rating DC 650
  • Coil Resistance 14
  • Coil Special Features UL Coil Insulation Class F
  • Coil Voltage Rating 3
  • Contact Voltage Rating 250
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 16
  • Insulation Creepage Between Contact & Coil 6
  • Contact Limiting Making Current 16
  • Contact Limiting Short-Time Current 16
  • Insulation Initial Dielectric Between Open Contacts 1250
  • Insulation Creepage Class 5.5 – 8
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Insulation Special Features Tracking Index of Relay Base PTI250
  • Product Weight 11
  • Contact Arrangement 1 Form A (NO)
  • Contact Current Class 10 – 20
  • Contact Current Rating (Max) 16
  • Contact Material W + AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Contact Special Features Flip-Flop Contacts
  • Relay Mounting Type Printed Circuit Board
  • Product Height 16
  • Product Length 29.1
  • Product Width 12.7
  • Insulation Clearance Class 5 – 8
  • Width Class (Mechanical) 12 – 16
  • Insulation Clearance Between Contact & Coil 6
  • Height Class (Mechanical) 15 – 16
  • Length Class (Mechanical) 25 – 30
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 70
  • Packaging Method Box & Tube
CAT-P851-T1B Power Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Power Relays
  1. PCB Power Relay: 40 Amp, Monostable CAT-P851-T1B
active
  • Power Relay Type Standard
  • Output Type AC
  • Enclosure Type Sealed
  • Output Switching Random
  • Coil Current .014
  • Contact Limiting Breaking Current 40
  • Input Voltage 0 – 110
  • Coil Magnetic System Monostable, AC
  • Coil Power Rating DC 1700
  • Coil Resistance 9.1
  • Coil Special Features UL Coil Insulation Class F
  • Coil Voltage Rating 12
  • Coil Voltage Rating 12
  • Contact Switching Load (Min) 500mA @ 12V
  • Contact Switching Voltage (Max) 600
  • Contact Voltage Rating 277
  • Insulation Initial Dielectric Between Contacts & Coil 4000
  • Output Current (Min) .5
  • Contact Limiting Continuous Current 40
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 40
  • Insulation Initial Resistance 1000
  • Insulation Initial Dielectric Between Adjacent Contacts 1500
  • Output Current Rating 0 – 3
  • Insulation Initial Dielectric Between Open Contacts 1500
  • Actuating System AC
  • Output Voltage Rating (AC Relays) 0 – 277
  • Output Voltage (Max) 600
  • Insulation Initial Dielectric Between Contacts & Coil 4000
  • Input Voltage 0 – 120
  • Insulation Creepage Class 8 – 9.5
  • Coil Power Rating 4
  • Output Current Rating 0 – 3
  • Insulation Initial Dielectric Between Coil & Contact Class 0 – 4000
  • Packaging Style Panel Mount
  • Insulation Special Features 8000V Initial Surge Withstand Voltage between Contacts & Coil
  • Product Weight 86
  • Contact Arrangement 2 Form A (NO)
  • Contact Current Class 30 – 50
  • Contact Current Rating (Max) 20
  • Contact Material AgCdO
  • Contact Number of Poles 2
  • Terminal Type Panel Mount Relay
  • Switch Arrangement (2) x 1 Form C
  • Relay Termination Type Printed Circuit Terminals
  • Relay Mounting Type Flange Mount
  • Product Height 30.73
  • Product Length 52.32
  • Product Width 34.54
  • Insulation Clearance Class 8 – 9.5
  • Width Class (Mechanical) 30 – 40
  • Insulation Clearance Between Contact & Coil 8
  • Height Class (Mechanical) 30 – 40
  • Length Class (Mechanical) 50 – 60
  • Operating Temperature Range -55 – 85
  • Environmental Ambient Temperature Class 70 – 85
  • Environmental Ambient Temperature (Max) 85
  • Packaging Method Box & Tray
CAT-P851-T1 Power Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Power Relays
  1. PCB Power Relay: 30 amp, Monostable DC CAT-P851-T1
active
  • Power Relay Type Standard
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 800 – 1000
  • Coil Power Rating DC 900
  • Coil Resistance 28
  • Coil Special Features UL Coil Insulation Class F
  • Coil Voltage Rating 5
  • Contact Switching Load (Min) 100mA @ 12V
  • Contact Switching Voltage (Max) 480
  • Contact Voltage Rating 250
  • Insulation Initial Dielectric Between Contacts & Coil 4000
  • Insulation Initial Dielectric Between Open Contacts 1500
  • Product Weight 18
  • Contact Arrangement 1 Form A (NO)
  • Contact Current Class 10 – 20
  • Contact Current Rating (Max) 20
  • Contact Material AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Termination Type Printed Circuit Terminals
  • Relay Mounting Type Printed Circuit Board
  • Product Height 15.7
  • Product Length 29
  • Product Width 21.5
  • Dimensions (L x W x H) (Approximate) 29 x 21.5 x 15.7
  • Width Class (Mechanical) 20 – 25
  • Height Class (Mechanical) 15 – 16
  • Length Class (Mechanical) 25 – 30
  • Operating Temperature Range -40 – 105
  • Environmental Ambient Temperature (Max) 105
  • Packaging Method Carton & Tube
CAT-AX41-C1782 Signal Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Signal Relays
  1. Signal Relay: Low profile, Monostable DC CAT-AX41-C1782
active
  • Product Type Relay
  • Relay Style Card SN
  • Relay Type Card SN Relay V23030
  • Contact Limiting Breaking Current .2
  • Contact Voltage Rating 30
  • Contact Voltage Rating 36
  • Signal Relay Coil Power Rating (DC) 720
  • Signal Relay Coil Voltage Rating 6
  • Signal Relay Coil Voltage Rating 5
  • Signal Relay Contact Switching Voltage (Max) 30
  • Signal Relay Contact Switching Voltage (Max) 36
  • Signal Relay Coil Magnetic System Monostable, DC
  • Coil Type Monostable
  • Contact Limiting Continuous Current 2
  • Coil Resistance 730
  • Contact Limiting Making Current 3
  • Power Consumption 800
  • Insulation Initial Resistance 1000
  • Insulation Initial Dielectric Between Coil/Contact Class 500 – 1000 V
  • Insulation Initial Dielectric Between Contacts and Coil 1000
  • Contact Limiting Short-Time Current 1
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Coil Power Rating Class 600 – 800 mW
  • Input Voltage 250
  • Input Voltage 250
  • Actuating System DC
  • Isolation (HF Parameter) -13.7dB @ 900MHz
  • Insertion Loss (HF Parameter) -.02dB @ 100MHz
  • Weight 22
  • Signal Relay Terminal Type PCB-THT
  • Signal Relay Contact Current Rating 2
  • Signal Relay Contact Arrangement 4 Form C (4 CO)
  • Contact Material AgNi+Au
  • Contact Number of Poles 4
  • Contact Current Class 0 – 2 A
  • Contact Plating Material Gold
  • Contact Special Features Bifurcated/Twin Contacts
  • Termination Type Through Hole
  • Signal Relay Mounting Type Printed Circuit Board
  • Dimensions (L x W x H) (Approximate) 39.7 x 32.4 x 10.2
  • Length 39.7
  • Width Class (Mechanical) 30 – 40 mm
  • Width 32.4
  • Height Class (Mechanical) 10 – 11 mm
  • Length Class (Mechanical) 35 – 40 mm
  • Height 10.2
  • Operating Temperature Range -40 – 70
  • Environmental Ambient Temperature (Max) 70
  • Environmental Ambient Temperature Class 50 – 70°C
  • Performance Type Standard
  • Packaging Method Box & Carton
  • Additional Features Earth Terminal
CAT-AX41-D1B Signal Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Signal Relays
  1. AXICOM D2N SENSITIVE CAT-AX41-D1B
active
  • Product Type Relay
  • Relay Style D2n Relay
  • Relay Type D2n Relay V23105
  • Contact Switching Load (Min) 10mA @ .2V
  • Contact Limiting Breaking Current 3
  • Contact Voltage Rating 220
  • Contact Voltage Rating 250
  • Signal Relay Coil Power Rating (DC) 400
  • Signal Relay Coil Voltage Rating 5
  • Signal Relay Contact Switching Voltage (Max) 220
  • Signal Relay Contact Switching Voltage (Max) 250
  • Signal Relay Coil Magnetic System Monostable, DC
  • Coil Type Monostable
  • Contact Limiting Continuous Current 3
  • Coil Resistance 200
  • Contact Limiting Making Current 3
  • Power Consumption 400
  • Insulation Initial Resistance 1000
  • Insulation Initial Dielectric Between Adjacent Contacts 750
  • Insulation Initial Dielectric Between Coil/Contact Class 1000 V – 1500 VA
  • Insulation Initial Dielectric Between Contacts and Coil 1050
  • Contact Limiting Short-Time Current 3
  • Insulation Initial Dielectric Between Open Contacts 750
  • Coil Power Rating Class 400 – 500 mW
  • Voltage Standing Wave Ration (HF Parameter) 1.04 @ 100MHz
  • Actuating System AC/DC
  • Isolation (HF Parameter) -20.7dB @ 900MHz
  • Insertion Loss (HF Parameter) -.02dB @ 100MHz
  • Weight 6
  • Insulation Special Features 1500V Initial Surge Withstand Voltage between Contacts & Coil
  • Signal Relay Terminal Type PCB-THT
  • Signal Relay Contact Current Rating 3
  • Signal Relay Contact Arrangement 2 Form C (CO)
  • Contact Number of Poles 2
  • Contact Current Class 2 – 5 A
  • Contact Plating Material Gold
  • Termination Type Through Hole
  • Signal Relay Mounting Type Printed Circuit Board
  • Length 20.2
  • Width Class (Mechanical) 8 – 10 mm
  • Width 10
  • Height Class (Mechanical) 10 – 11 mm
  • Length Class (Mechanical) 20 – 25 mm
  • Height 11
  • Operating Temperature Range -40 – 85
  • Environmental Ambient Temperature (Max) 85
  • Environmental Ambient Temperature Class 70 – 85°C
  • Performance Type Standard
  • Packaging Method Box & Tube
CAT-SCH691-SR1D Power Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Power Relays
  1. Force Guided Power Relay, DIN-rail CAT-SCH691-SR1D
active
  • Power Relay Type Force-Guided
  • Contact Limiting Breaking Current 6
  • Coil Magnetic System Monostable, AC
  • Coil Power Rating Class 600 – 800
  • Coil Power Rating AC 2.4
  • Coil Power Rating DC 700
  • Coil Resistance 120
  • Coil Special Features Coil Suppression Diode
  • Coil Voltage Rating 24
  • Coil Voltage Rating 12
  • Contact Switching Load (Min) 10mA @ 5V
  • Contact Switching Voltage (Max) 250
  • Contact Voltage Rating 250
  • Insulation Initial Dielectric Between Contacts & Coil 4000
  • Contact Limiting Continuous Current 6
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 6
  • Insulation Initial Dielectric Between Adjacent Contacts 2000
  • Contact Limiting Short-Time Current 6
  • Insulation Initial Dielectric Between Open Contacts 1500
  • Insulation Creepage Class 5.5 – 8
  • Insulation Initial Dielectric Between Coil & Contact Class 3500 – 4000
  • Product Weight 50
  • Contact Arrangement 2 Form C (CO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 6
  • Contact Material AgNi
  • Contact Number of Poles 2
  • Terminal Type Screwless Clamp Connectors
  • Contact Special Features Force Guided Contacts
  • Relay Mounting Type DIN Rail
  • Product Height 54
  • Product Length 87
  • Product Width 20
  • Insulation Clearance Class 5 – 8
  • Width Class (Mechanical) 16 – 20
  • Insulation Clearance Between Contact & Coil 8
  • Height Class (Mechanical) 50
  • Length Class (Mechanical) 60
  • Environmental Ambient Temperature Class -25 – 50
  • Environmental Ambient Temperature (Max) 50
  • Packaging Method Box & Carton
  • Comment Well suited for emergency shut-off, machine control, elevator and escalator control, light barrier control
CAT-P851-SS61E Power Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Power Relays
  1. P&B SSRK SERIES SOLID STATE RELAYS CAT-P851-SS61E
active
  • Power Relay Type Solid State
  • Output Type AC
  • Output Switching Zero
  • Input Voltage 3 – 32
  • Insulation Initial Dielectric Between Contacts & Coil 4000
  • Output Current (Min) .15
  • Output Voltage Rating (DC Relays) 24 – 240
  • Output Current Rating .15 – 20
  • Output Voltage (Max) 240
  • Input Voltage Typical 3
  • Case Color Black
  • Product Weight 280
  • Contact Arrangement 1 Form A (SPST-NO)
  • Contact Current Rating (Max) 10
  • Switch Arrangement 1 Form A (SPST-NO)
  • Relay Termination Type Finger-Safe (IP20) Screw Clamps
  • Relay Mounting Type DIN Rail
  • Coupling Optical
  • Relay Housing Style DIN Mount with Integral Heatsink
  • Dimensions (L x W x H) (Approximate) 82.3 x 22.5 x 111.5
  • Operating Temperature Range -30 – 80
  • R-Switch & slimSSR Relays Yes
CAT-P851-OA1 Power Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Power Relays
  1. Solid State Relays: PCB mount CAT-P851-OA1
active
  • Power Relay Type Solid State
  • Output Type AC
  • Output Switching Zero
  • Input Voltage 3 – 8
  • Insulation Initial Dielectric Between Contacts & Coil 4000
  • Output Current (Min) .05
  • Output Current Rating .05 – 5
  • Output Voltage Rating (AC Relays) 24 – 280
  • Output Voltage (Max) 280
  • Input Voltage Typical 5
  • Case Color Black
  • Product Weight 35
  • Contact Arrangement 1 Form A (SPST-NO)
  • Switch Arrangement 1 Form A (SPST-NO)
  • Relay Termination Type Printed Circuit Terminals
  • Relay Mounting Type Printed Circuit Board
  • Coupling Optical
  • Relay Housing Style Industry Standard
  • Dimensions (L x W x H) (Approximate) 43.1 x 15.2 x 31.7
  • Operating Temperature Range -30 – 80
  • R-Switch & slimSSR Relays No
CAT-P8719-SS62 Power Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Power Relays
  1. Solid State Relays: Chassis mount CAT-P8719-SS62
active
  • Power Relay Type Solid State
  • Output Type DC
  • Input Voltage 3.5 – 32
  • Insulation Initial Dielectric Between Contacts & Coil 1500
  • Output Voltage Rating (DC Relays) 200
  • Output Voltage (Max) 200
  • Input Voltage Typical 3.5 – 32
  • Output Current Rating 40
  • Case Color Black
  • Product Weight 145
  • Contact Arrangement 1 Form A (SPST-NO)
  • Switch Arrangement 1 Form A (SPST-NO)
  • Relay Termination Type Screws
  • Relay Mounting Type Chassis Mount
  • Coupling Optical
  • Relay Housing Style Hockey Puck
  • Dimensions (L x W x H) (Approximate) 45 x 58 x 43.4
  • Operating Temperature Range -30 – 80
  • R-Switch & slimSSR Relays No
CAT-SCH691-SR1A Power Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Power Relays
  1. Force Guided Power Relay, 4 Poles CAT-SCH691-SR1A
active
  • Power Relay Type Force-Guided
  • Coil Current .007
  • Contact Limiting Breaking Current 8
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 600 – 800
  • Coil Power Rating DC 800
  • Coil Resistance 31
  • Coil Voltage Rating 5
  • Contact Switching Load (Min) 10mA @ 5V
  • Contact Switching Voltage (Max) 400
  • Contact Voltage Rating 250
  • Insulation Initial Dielectric Between Contacts & Coil 4000
  • Contact Limiting Continuous Current 8
  • Insulation Creepage Between Contact & Coil 10
  • Contact Limiting Making Current 8
  • Insulation Initial Dielectric Between Adjacent Contacts 2500
  • Contact Limiting Short-Time Current 8
  • Insulation Initial Dielectric Between Open Contacts 1500
  • Insulation Creepage Class 8
  • Insulation Initial Dielectric Between Coil & Contact Class 3500 – 4000
  • Product Weight 30
  • Contact Arrangement 2 Form A (NO) + 2 Form B (NC)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 8
  • Contact Material AgSnO2
  • Contact Number of Poles 4
  • Terminal Type PCB-THT
  • Contact Special Features Force Guided Contacts
  • Relay Mounting Type Printed Circuit Board
  • Product Height 16.5
  • Product Length 40
  • Product Width 13
  • Insulation Clearance Class 8
  • Width Class (Mechanical) 12 – 16
  • Insulation Clearance Between Contact & Coil 10
  • Height Class (Mechanical) 16 – 20
  • Length Class (Mechanical) 35 – 40
  • Environmental Ambient Temperature Class -25 – 70
  • Environmental Ambient Temperature (Max) 70
  • Packaging Method Box & Tube
  • Comment Well suited for emergency shut-off, machine control, elevator and escalator control, light barrier control
CAT-P851-SS61C Power Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Power Relays
  1. P&B SSRD SERIES SOLID STATE RELAYS CAT-P851-SS61C
active
  • Power Relay Type Solid State
  • Output Type AC
  • Output Switching Zero
  • Input Voltage 4 – 15
  • Insulation Initial Dielectric Between Contacts & Coil 4000
  • Output Current (Min) .1
  • Output Current Rating .1 – 25
  • Output Voltage Rating (AC Relays) 24 – 280
  • Output Voltage (Max) 280
  • Input Voltage Typical 4 – 15
  • Case Color Black
  • Product Weight 90
  • Contact Arrangement (2) x 1 Form A (SPST-NO)
  • Switch Arrangement (2) x 1 Form A (SPST-NO)
  • Relay Termination Type .25 x .032 Quick Connect Terminals
  • Relay Mounting Type Chassis Mount
  • Coupling Optical
  • Relay Housing Style Industry Standard
  • Dimensions (L x W x H) (Approximate) 44.5 x 57x 30.2
  • Operating Temperature Range -30 – 80
  • R-Switch & slimSSR Relays No
CAT-SCH691-SR1 Power Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Power Relays
  1. Force Guided Power Relay, 2 Poles CAT-SCH691-SR1
active
  • Power Relay Type Force-Guided
  • Contact Limiting Breaking Current 6
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 600 – 800
  • Coil Power Rating DC 671
  • Coil Resistance 36
  • Coil Voltage Rating 5
  • Contact Switching Load (Min) 10mA @ 5V
  • Contact Switching Voltage (Max) 400
  • Contact Voltage Rating 250
  • Insulation Initial Dielectric Between Contacts & Coil 4000
  • Contact Limiting Continuous Current 6
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 6
  • Insulation Initial Dielectric Between Adjacent Contacts 3000
  • Contact Limiting Short-Time Current 6
  • Insulation Initial Dielectric Between Open Contacts 1500
  • Insulation Creepage Class 5.5 – 8
  • Insulation Initial Dielectric Between Coil & Contact Class 3500 – 4000
  • Product Weight 20
  • Contact Arrangement 1 Form A (NO) + 1 Form B (NC)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 6
  • Contact Material AgNi
  • Contact Number of Poles 2
  • Terminal Type PCB-THT
  • Contact Special Features Force Guided Contacts
  • Relay Mounting Type Printed Circuit Board
  • Product Height 25.5
  • Product Length 29
  • Product Width 12.6
  • Insulation Clearance Class 5 – 8
  • Width Class (Mechanical) 12 – 16
  • Insulation Clearance Between Contact & Coil 8
  • Height Class (Mechanical) 25 – 30
  • Length Class (Mechanical) 25 – 30
  • Operating Temperature Range -40 – 70
  • Environmental Ambient Temperature Class -25 – 70
  • Environmental Ambient Temperature (Max) 70
  • Packaging Method Box & Tube
  • Comment Well suited for emergency shut-off, machine control, elevator and escalator control, light barrier control
CAT-P851-SS61 Power Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Power Relays
  1. P&B SSR SERIES SOLID STATE RELAYS CAT-P851-SS61
active
  • Power Relay Type Solid State
  • Output Type AC
  • Output Switching Zero
  • Input Voltage 3 – 32
  • Insulation Initial Dielectric Between Contacts & Coil 4000
  • Output Current (Min) .1
  • Output Current Rating .1 – 125
  • Output Voltage Rating (AC Relays) 48 – 660
  • Output Voltage (Max) 660
  • Input Voltage Typical 4 – 32
  • Case Color Black
  • Product Weight 98
  • Contact Arrangement 1 Form A (SPST-NO)
  • Switch Arrangement 1 Form A (SPST-NO)
  • Relay Termination Type Screws
  • Relay Mounting Type Chassis Mount
  • Coupling Optical
  • Relay Housing Style Hockey Puck
  • Dimensions (L x W x H) (Approximate) 45 x 57.8 x 43.4
  • Operating Temperature Range -30 – 80
  • R-Switch & slimSSR Relays No
CAT-SCH691-R997 Power Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Power Relays
  1. PCB Power Relay: 12-16 Amp, Monostable CAT-SCH691-R997
active
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 12
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 300 – 400
  • Coil Power Rating DC 400
  • Coil Resistance 47
  • Coil Special Features UL Coil Insulation Class F
  • Coil Voltage Rating 5
  • Contact Switching Load (Min) 100mA @ 12V
  • Contact Switching Voltage (Max) 277
  • Contact Switching Voltage (Max) 250
  • Contact Voltage Rating 250
  • Contact Voltage Rating 250
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 16
  • Insulation Creepage Between Contact & Coil 10
  • Contact Limiting Making Current 30
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Creepage Class 8
  • Insulation Initial Dielectric Between Coil & Contact Class 4000 – 5000
  • Insulation Special Features Tracking Index of Relay Base PTI250
  • Product Weight 10
  • Contact Arrangement 1 Form A (NO)
  • Contact Current Class 10 – 20
  • Contact Current Rating (Max) 12
  • Contact Material AgNi90/10
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Product Height 15.7
  • Product Length 29
  • Product Width 12.7
  • Insulation Clearance Class 8
  • Width Class (Mechanical) 12 – 16
  • Insulation Clearance Between Contact & Coil 10
  • Height Class (Mechanical) 15 – 16
  • Length Class (Mechanical) 25 – 30
  • Environmental Ambient Temperature (Max) 85
  • Packaging Method Box & Carton
CAT-P851-SS61B Power Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Power Relays
  1. P&B SSRC SERIES SOLID STATE RELAYS CAT-P851-SS61B
active
  • Power Relay Type Solid State
  • Output Type AC
  • Output Switching Zero
  • Input Voltage 3 – 15
  • Insulation Initial Dielectric Between Contacts & Coil 4000
  • Output Current (Min) .06
  • Output Voltage Rating (DC Relays) 12 – 280
  • Output Current Rating .06 – 5
  • Output Voltage Rating (AC Relays) 12 – 280
  • Output Voltage (Max) 280
  • Input Voltage Typical 3 – 15
  • Case Color Black
  • Product Weight 11
  • Contact Arrangement 1 Form A (SPST-NO)
  • Switch Arrangement 1 Form A (SPST-NO)
  • Relay Termination Type Printed Circuit Terminals
  • Relay Mounting Type Printed Circuit Board
  • Coupling Optical
  • Relay Housing Style SIP
  • Dimensions (L x W x H) (Approximate) 43.1 x 7.6 x 25.4
  • Operating Temperature Range -30 – 80
  • R-Switch & slimSSR Relays Yes
CAT-P851-SS61G Power Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Power Relays
  1. P&B SSRT SERIES SOLID STATE RELAYS CAT-P851-SS61G
active
  • Power Relay Type Solid State
  • Output Type AC
  • Output Switching Zero
  • Input Voltage 3 – 32
  • Insulation Initial Dielectric Between Contacts & Coil 4000
  • Output Current (Min) .1
  • Output Current Rating .1 – 10
  • Output Voltage Rating (AC Relays) 24 – 280
  • Output Voltage (Max) 280
  • Input Voltage 90 – 280
  • Input Voltage Typical 90 – 280
  • Case Color Black
  • Product Weight 98
  • Contact Arrangement 1 Form A (SPST-NO)
  • Switch Arrangement 1 Form A (SPST-NO)
  • Relay Termination Type Screws
  • Relay Mounting Type Chassis Mount
  • Coupling Optical
  • Relay Housing Style Hockey Puck
  • Dimensions (L x W x H) (Approximate) 45 x 57.8 x 36.5
  • Operating Temperature Range -30 – 80
  • R-Switch & slimSSR Relays No
CAT-OE4-SD69 Power Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Power Relays
  1. STD OEG PCB PCFN Solar Power Relays CAT-OE4-SD69
active
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 100 – 150
  • Coil Power Rating DC 150
  • Coil Resistance 17
  • Coil Special Features Sensitive Version
  • Coil Voltage Rating 3
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 250
  • Contact Switching Voltage (Max) 24
  • Contact Voltage Rating 250
  • Contact Voltage Rating 24
  • Insulation Initial Dielectric Between Contacts & Coil 4000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 3.2
  • Contact Limiting Making Current 10
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Creepage Class 3 – 5.5
  • Insulation Initial Dielectric Between Coil & Contact Class 3500 – 4000
  • Product Weight 11
  • Contact Arrangement 1 Form A (NO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material Ag Alloy
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Product Height 25
  • Product Length 24
  • Product Width 10
  • Insulation Clearance Class 0 – 2.5
  • Width Class (Mechanical) 8 – 10
  • Insulation Clearance Between Contact & Coil 1.6
  • Height Class (Mechanical) 20 – 25
  • Length Class (Mechanical) 20 – 25
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 70
  • Packaging Method Box & Tray
CAT-OE4-OJ1 Power Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Power Relays
  1. STD OEG Miniature PCB OJ/OJE Pow Relays CAT-OE4-OJ1
active
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 150 – 200
  • Coil Power Rating DC 200
  • Coil Resistance 20
  • Coil Special Features Sensitive Version
  • Coil Voltage Rating 3
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 277
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 250
  • Contact Voltage Rating 30
  • Insulation Initial Dielectric Between Contacts & Coil 4000
  • Contact Limiting Continuous Current 3
  • Insulation Creepage Between Contact & Coil 9.4
  • Contact Limiting Making Current 3
  • Contact Limiting Short-Time Current 3
  • Insulation Initial Dielectric Between Open Contacts 750
  • Insulation Creepage Class 5.5 – 8
  • Insulation Initial Dielectric Between Coil & Contact Class 3500 – 4000
  • Insulation Special Features Tracking Index of Relay Base PTI250
  • Product Weight 9
  • Contact Arrangement 1 Form A (NO)
  • Contact Current Class 2 – 5
  • Contact Current Rating (Max) 3
  • Contact Material Ag
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Termination Type Through Hole
  • Relay Mounting Type Printed Circuit Board
  • Product Height 14.7
  • Product Length 18.2
  • Product Width 10.2
  • Insulation Clearance Class 2.5 – 4
  • Width Class (Mechanical) 10 – 12
  • Insulation Clearance Between Contact & Coil 7.7
  • Height Class (Mechanical) 14 – 15
  • Length Class (Mechanical) 16 – 20
  • Environmental Ambient Temperature Class 85 – 105
  • Environmental Ambient Temperature (Max) 90
  • Packaging Method Box
CAT-P851-IA1 Power Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Power Relays
  1. SSRs: PCB Mount, slim relays CAT-P851-IA1
active
  • Power Relay Type Solid State
  • Output Type DC
  • Output Switching Zero
  • Input Voltage 18 – 36
  • Insulation Initial Dielectric Between Contacts & Coil 4000
  • Output Current (Min) 0
  • Logic Voltage 5
  • Output Voltage Rating (DC Relays) 30
  • Output Voltage (Max) 30
  • Input Voltage 90 – 140
  • Input Voltage Typical 120
  • Input Voltage Typical 120
  • Output Current Rating .05
  • Case Color Yellow
  • Product Weight 35
  • Contact Arrangement 1 Form A (SPST-NO)
  • Switch Arrangement 1 Form A (SPST-NO)
  • Relay Termination Type Printed Circuit Terminals
  • Relay Mounting Type Printed Circuit Board
  • Coupling Optical
  • Relay Housing Style Industry Standard
  • Dimensions (L x W x H) (Approximate) 43.1 x 15.2 x 31.7
  • Operating Temperature Range -30 – 80
  • R-Switch & slimSSR Relays No
CAT-P851-OD1 Power Relays  1
PRODUCT
  1. Relays, Contactors & Switches
  2. Power Relays
  1. P&B SSR OUTPUT DC MODULES CAT-P851-OD1
active
  • Power Relay Type Solid State
  • Output Type DC
  • Output Switching Zero
  • Input Voltage 3 – 8
  • Insulation Initial Dielectric Between Contacts & Coil 4000
  • Output Current (Min) .01
  • Output Voltage Rating (DC Relays) 3 – 250
  • Output Voltage (Max) 250
  • Input Voltage Typical 24
  • Output Current Rating .01 – 1
  • Case Color Red
  • Product Weight 35
  • Contact Arrangement 1 Form A (SPST-NO)
  • Switch Arrangement 1 Form A (SPST-NO)
  • Relay Termination Type Printed Circuit Terminals
  • Relay Mounting Type Printed Circuit Board
  • Coupling Optical
  • Relay Housing Style Industry Standard
  • Dimensions (L x W x H) (Approximate) 43.1 x 15.2 x 31.7
  • Operating Temperature Range -30 – 80
  • R-Switch & slimSSR Relays No