HET-A-03C Shielded Terminators
  • Cable Type Multi-Conductors Unshielded
  • Product Type Terminator
  • Insulation Sleeve Material Radiation Crosslinked Modified Polyvinylidene Fluoride
  • Ferrule Material Copper Alloy
  • Plating Material Electroless Nickel
  • Insert Type Meltable Sealing Ring
  • Wire Bundle Diameter (Max) 4.2
  • Operating Temperature Range -65 – 175
  • Comment For routing unshielded primary wires, adapters without drilled stars (DS).
HET-A-04C Shielded Terminators
  • Cable Type Multi-Conductors Shielded
  • Product Type Terminator
  • Insulation Sleeve Material Radiation Crosslinked Modified Polyvinylidene Fluoride
  • Ferrule Material Copper Alloy
  • Plating Material Electroless Nickel
  • Insert Material Sn96 Ag Solder Alloy
  • Shield Material Copper Braid with Activated Rosin Flux
  • Insert Type Solder Preform with Activated Rosin Flux
  • Shield Plating Material Pre-Tin
  • Cable Bundle Diameter (Max) 8.9
  • Cable Bundle Diameter (Min) 4.3
  • Wire Bundle Diameter (Max) 4.2
  • Cable Size Medium
  • Cable Shield Diameter (Min) 3.5
  • Cable Shield Diameter (Max) 6.2
  • Operating Temperature Range -65 – 175
  • Comment Terminates 1 to 4 cable shields to one ferrule.
HET-A-03B Shielded Terminators
  • Cable Type Multi-Conductors Unshielded
  • Product Type Terminator
  • Color Olive Drab
  • Insulation Sleeve Material Radiation Crosslinked Modified Polyvinylidene Fluoride
  • Ferrule Material Copper Alloy
  • Plating Material Cadmium Plating over Electroless Nickel
  • Insert Type Meltable Sealing Ring
  • Wire Bundle Diameter (Max) 4.2
  • Operating Temperature Range -65 – 175
  • Salt Spray Resistance 500
  • Comment For routing unshielded primary wires, adapters without drilled stars (DS).
HET-A-04B Shielded Terminators
  • Cable Type Multi-Conductors Shielded
  • Product Type Terminator
  • Color Olive Drab
  • Insulation Sleeve Material Radiation Crosslinked Modified Polyvinylidene Fluoride
  • Ferrule Material Copper Alloy
  • Plating Material Cadmium Plating over Electroless Nickel
  • Insert Material Sn96 Ag Solder Alloy
  • Shield Material Copper Braid with Activated Rosin Flux
  • Insert Type Solder Preform with Activated Rosin Flux
  • Shield Plating Material Pre-Tin
  • Cable Bundle Diameter (Max) 8.9
  • Cable Bundle Diameter (Min) 4.3
  • Wire Bundle Diameter (Max) 4.2
  • Cable Size Medium
  • Cable Shield Diameter (Min) 3.5
  • Cable Shield Diameter (Max) 6.2
  • Operating Temperature Range -65 – 175
  • Salt Spray Resistance 500
  • Comment Terminates 1 to 4 cable shields to one ferrule.
HET-A-02C Shielded Terminators
  • Cable Type Multi-Conductors Shielded
  • Product Type Terminator
  • Insulation Sleeve Material Radiation Crosslinked Modified Polyvinylidene Fluoride
  • Ferrule Material Copper Alloy
  • Plating Material Electroless Nickel
  • Insert Material Sn96 Ag Solder Alloy
  • Shield Material Copper Braid with Activated Rosin Flux
  • Insert Type Solder Preform with Activated Rosin Flux
  • Shield Plating Material Pre-Tin
  • Cable Bundle Diameter (Max) 6.9
  • Cable Bundle Diameter (Min) 3.1
  • Wire Bundle Diameter (Max) 4.2
  • Cable Size Small
  • Cable Shield Diameter (Min) 2.4
  • Cable Shield Diameter (Max) 5.3
  • Operating Temperature Range -65 – 175
  • Comment Terminates 1 to 4 cable shields to one ferrule.
HET-A-02B Shielded Terminators
  • Cable Type Multi-Conductors Shielded
  • Product Type Terminator
  • Color Olive Drab
  • Insulation Sleeve Material Radiation Crosslinked Modified Polyvinylidene Fluoride
  • Ferrule Material Copper Alloy
  • Plating Material Cadmium Plating over Electroless Nickel
  • Insert Material Sn96 Ag Solder Alloy
  • Shield Material Copper Braid with Activated Rosin Flux
  • Insert Type Solder Preform with Activated Rosin Flux
  • Shield Plating Material Pre-Tin
  • Cable Bundle Diameter (Max) 6.9
  • Cable Bundle Diameter (Min) 3.1
  • Wire Bundle Diameter (Max) 4.2
  • Cable Size Small
  • Cable Shield Diameter (Min) 2.4
  • Cable Shield Diameter (Max) 5.3
  • Operating Temperature Range -65 – 175
  • Salt Spray Resistance 500
  • Comment Terminates 1 to 4 cable shields to one ferrule.
HET-A-05B Shielded Terminators
  • Cable Type Multi-Conductors Shielded
  • Product Type Terminator
  • Color Olive Drab
  • Insulation Sleeve Material Radiation Crosslinked Modified Polyvinylidene Fluoride
  • Ferrule Material Copper Alloy
  • Plating Material Cadmium Plating over Electroless Nickel
  • Shield Material Solder Impregnated, Flux Coated Copper
  • Insert Type Solder
  • Cable Bundle Diameter (Max) 11.8
  • Cable Bundle Diameter (Min) 5
  • Wire Bundle Diameter (Max) 7.5
  • Cable Size Large
  • Cable Shield Diameter (Min) 4
  • Cable Shield Diameter (Max) 11.8
  • Operating Temperature Range -65 – 175
  • Salt Spray Resistance 500
  • Comment Requires special HexaShield adapter, contact Raychem Product Management.
HET-A-05C Shielded Terminators
  • Cable Type Multi-Conductors Shielded
  • Product Type Terminator
  • Insulation Sleeve Material Radiation Crosslinked Modified Polyvinylidene Fluoride
  • Ferrule Material Copper Alloy
  • Plating Material Electroless Nickel
  • Shield Material Solder Impregnated, Flux Coated Copper
  • Insert Type Solder
  • Cable Bundle Diameter (Max) 11.8
  • Cable Bundle Diameter (Min) 5
  • Wire Bundle Diameter (Max) 7.5
  • Cable Size Large
  • Cable Shield Diameter (Min) 4
  • Cable Shield Diameter (Max) 11.8
  • Operating Temperature Range -65 – 175
  • Comment Requires special HexaShield adapter, contact Raychem Product Management.
CN6497-000 Shielded Terminators
  • Cable Type Multi-Conductors Shielded
  • Product Type Terminator
  • Insulation Sleeve Material Radiation Crosslinked Modified Polyvinylidene Fluoride
  • Ferrule Material Copper Alloy
  • Plating Material Electroless Nickel
  • Shield Material Solder Impregnated, Flux Coated Copper
  • Insert Type Solder
  • Cable Bundle Diameter (Max) 6.9
  • Cable Bundle Diameter (Min) 3.1
  • Wire Bundle Diameter (Max) 4.2
  • Cable Size Large
  • Cable Shield Diameter (Min) 2.4
  • Cable Shield Diameter (Max) 5.3
  • Operating Temperature Range -65 – 200