CAT-IXSU Power Cable Terminations  1
PRODUCT
  1. Power Systems
  2. Power Cable Terminations
  1. IXSU HEAT-SHRINK TERMINATION CAT-IXSU
active
  • Power Cable Termination Technology Heat Shrink
  • Cable Shield Style Wire
  • Insulation Plastic
  • Termination Length 300
  • Mechanical Connectors Included No
  • Mechanical Lug Included (Shield) 1
  • Shelf Life No Limitation
  • Product Family IXSU-F
  • Number of Cores 1
  • Power Cable Termination Voltage Class 19/33(36)
  • Mechanical Lug Included (M12, Conductor) 1
  • Mechanical Lug Included (M16, Conductor) 1
  • Cross-Section Range 10 – 25
  • Power Cable Termination Insulation Diameter 13.7 – 20.8
  • Power Cable Termination Tail Length 450
  • Operating Temperature Range 0 – 95
  • Application Type Indoor
  • Design Specification CENELEC HD 620 A2
  • Power Cable Termination Product Availability AMERICAS
  • Installation Instruction Czech
CAT-OXSU Power Cable Terminations  1
PRODUCT
  1. Power Systems
  2. Power Cable Terminations
  1. Heat Shrinkable Outdoor Termination kits CAT-OXSU
active
  • Power Cable Termination Technology Heat Shrink
  • Cable Shield Style Wire
  • Insulation Plastic
  • Sheds per Phase 1
  • Termination Length 300
  • Mechanical Connectors Included No
  • Mechanical Lug Included (Shield) 1
  • Shelf Life No Limitation
  • Number of Cores 1
  • Power Cable Termination Voltage Class 19/33(36)
  • Mechanical Lug Included (M12, Conductor) 1
  • Mechanical Lug Included (M16, Conductor) 1
  • Cross-Section Range 10 – 35
  • Power Cable Termination Insulation Diameter 13.7 – 16.3
  • Shed Inside Diameter 120
  • Power Cable Termination Tail Length 450
  • Application Type Outdoor
  • Design Specification CENELEC HD 620 A2
  • Power Cable Termination Product Availability AMERICAS
  • Installation Instruction Danish
CAT-TFT-R Power Cable Terminations  1
PRODUCT
  1. Power Systems
  2. Power Cable Terminations
  1. Indoor and Outdoor Cable Terminations CAT-TFT-R
active
  • Power Cable Termination Technology Cold Applied
  • Cable Shield Style None
  • Insulation Plastic
  • Sheds per Phase 3
  • Mechanical Connectors Included No
  • Shelf Life 3 Years
  • Number of Cores 1
  • Power Cable Termination Voltage Class ≤ 15
  • Application Type Indoor/Outdoor
  • Design Specification IEEE 48
  • Power Cable Termination Product Availability AMERICAS
CAT-CST Power Cable Terminations  1
PRODUCT
  1. Power Systems
  2. Power Cable Terminations
  1. Cold Shrink Terminations up to 35 kV CAT-CST
active
GB/T 28427
  • Power Cable Termination Technology Cold Applied
  • Cable Shield Style CU-Tape
  • Insulation Plastic (XLPE)
  • Sheds per Phase 3
  • Termination Length 289
  • Mechanical Connectors Included No
  • Mechanical Lug Included (Shield) No
  • Shelf Life 2 Years
  • Number of Cores 1
  • Power Cable Termination Voltage Class ≤ 15
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) No
  • Armoring AL Wire
  • Cross-Section Range 25 – 35
  • Power Cable Termination Insulation Diameter 11.7 – 18
  • Shed Inside Diameter 135 – 165
  • Sheath Outside Diameter 27.94
  • Length (Installed) 320.04
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) II
  • Design Specification GB/T 12706.4
  • Power Cable Termination Product Availability AMERICAS
  • Installation Instruction English
CAT-HVT-Z-J-SJ Power Cable Terminations  1
PRODUCT
  1. Power Systems
  2. Power Cable Terminations
  1. HVT-Z-J HV TERMINATIONS - JCN CABLES CAT-HVT-Z-J-SJ
active
  • Power Cable Termination Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 1
  • Mechanical Connectors Included No
  • Product Family HVT
  • Number of Cores 1
  • Power Cable Termination Voltage Class ≤ 15
  • Power Cable Termination Insulation Diameter 15.24 – 24.13
  • Shed Inside Diameter 115.06
  • Sheath Outside Diameter 26.67
  • Length (Installed) 292.1
  • Power Cable Termination Conductor Diameter 7.41 – 8.43
  • Application Type Indoor
  • Design Specification IEEE 48
  • Power Cable Termination Product Availability AMERICAS
CAT-TFT-E Power Cable Terminations  1
PRODUCT
  1. Power Systems
  2. Power Cable Terminations
  1. One Core Polymeric Cables Termination CAT-TFT-E
active
  • Power Cable Termination Technology Cold Applied
  • Cable Shield Style JCN
  • Insulation Plastic
  • Sheds per Phase 3
  • Mechanical Connectors Included No
  • Shelf Life 3 Years
  • Number of Cores 1
  • Power Cable Termination Voltage Class ≤ 15
  • Application Type Indoor
  • Design Specification IEEE 48
  • Power Cable Termination Product Availability AMERICAS
CAT-HVT-Z Power Cable Terminations  1
PRODUCT
  1. Power Systems
  2. Power Cable Terminations
  1. Terminations for Shielded Cables CAT-HVT-Z
active
  • Power Cable Termination Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 1
  • Mechanical Connectors Included No
  • Product Family HVT
  • Number of Cores 1
  • Power Cable Termination Voltage Class ≤ 15
  • Power Cable Termination Insulation Diameter 8.89 – 15.24
  • Shed Inside Diameter 115.06
  • Sheath Outside Diameter 24.13
  • Length (Installed) 292.1
  • Power Cable Termination Conductor Diameter 4.67 – 7.41
  • Application Type Outdoor
  • Design Specification IEEE 48
  • Power Cable Termination Product Availability AMERICAS
CAT-EPKT Power Cable Terminations  1
PRODUCT
  1. Power Systems
  2. Power Cable Terminations
  1. EPKT HEAT-SHRINK TERMINATION SYSTEM CAT-EPKT
active
  • Power Cable Termination Technology Heat Shrink
  • Cable Shield Style None
  • Insulation Plastic
  • Mechanical Connectors Included No
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) No
  • Shelf Life Unlimited
  • Product Family EPKT
  • Compression Lug Included (Shield) No
  • Number of Cores 4
  • Power Cable Termination Voltage Class 1
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) No
  • Armoring Tape
  • Cross-Section Range 4 – 16
  • Power Cable Termination Conductor Diameter 4 – 9
  • Application Type Indoor/Outdoor
  • Design Specification CENELEC 50393
  • Power Cable Termination Product Availability AMERICAS
  • Installation Instruction Bulgarian
CAT-OHVT-C Power Cable Terminations  1
PRODUCT
  1. Power Systems
  2. Power Cable Terminations
  1. HV OUTDOOR TERMINATION COMPOSITE CAT-OHVT-C
active
IEC 60815-1 IEC 60840 IEEE 48
  • Power Cable Termination Technology Cold Applied
  • Cable Shield Style Adaptable
  • Insulation XLPE
  • Mechanical Connectors Included Yes
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Product Family 748
  • Compression Lug Included (Shield) No
  • Number of Cores 1
  • Power Cable Termination Voltage Class ≤ 123
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) Yes
  • Cross-Section Range 95 – 2500
  • Creepage Distance 2164
  • Power Cable Termination Insulation Diameter 34 – 108
  • Sheath Outside Diameter 0 – 110
  • Length (Installed) 1264
  • Power Cable Termination Tail Length 500
  • Pollution Level (IEC 60815) I
  • Power Cable Termination Product Availability Worldwide
  • Minimum Order Quantity 1
  • Installation Instruction English
CAT-OHVT-G Power Cable Terminations  1
PRODUCT
  1. Power Systems
  2. Power Cable Terminations
  1. HV OUTDOOR TERMINATION DRY TYPE OHVT-G CAT-OHVT-G
active
IEC 60815-1 IEC 60840 IEEE 48
  • Power Cable Termination Technology Cold Applied
  • Cable Shield Style Adaptable
  • Insulation XLPE
  • Mechanical Connectors Included Yes
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Product Family 748
  • Compression Lug Included (Shield) No
  • Number of Cores 1
  • Power Cable Termination Voltage Class ≤ 145
  • Cross-Section Range 95 – 2500
  • Power Cable Termination Insulation Diameter 34 - 108
  • Pollution Level (IEC 60815) IV
  • Minimum Order Quantity 1
CAT-OHVT-F Power Cable Terminations  1
PRODUCT
  1. Power Systems
  2. Power Cable Terminations
  1. HV DRY FLEXIBLE TERMINATIONS CAT-OHVT-F
active
IEC 60815-1 IEC 60840 IEEE 48
  • Power Cable Termination Technology Cold Applied
  • Cable Shield Style Adaptable
  • Insulation XLPE
  • Mechanical Connectors Included Yes
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) No
  • Product Family 748
  • Compression Lug Included (Shield) No
  • Number of Cores 1
  • Power Cable Termination Voltage Class ≤ 145
  • Cross-Section Range 240 – 1200
  • Power Cable Termination Insulation Diameter 49 – 78
  • Minimum Order Quantity 1
CAT-OHVT-FS Power Cable Terminations  1
PRODUCT
  1. Power Systems
  2. Power Cable Terminations
  1. HV DRY FLEXIBLE SELF-SUPPORT TERMINATION CAT-OHVT-FS
active
IEC 60840 IEC 61076-2-104
  • Power Cable Termination Technology Cold Applied
  • Cable Shield Style Adaptable
  • Insulation XLPE
  • Mechanical Connectors Included Yes
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) No
  • Product Family 748
  • Compression Lug Included (Shield) No
  • Number of Cores 1
  • Power Cable Termination Voltage Class ≤ 145
  • Cross-Section Range 240 – 1200
  • Power Cable Termination Insulation Diameter 49 – 78
  • Minimum Order Quantity 1
CAT-OHVT-72H Power Cable Terminations  1
PRODUCT
  1. Power Systems
  2. Power Cable Terminations
  1. HV OUTDOOR HEAT SHRINK TERMINATION 72 KV CAT-OHVT-72H
active
IEC 60815-1 IEC 60840
  • Power Cable Termination Technology Heat Shrink
  • Cable Shield Style AL-Wire & Al-Tape
  • Insulation Plastic (XLPE)
  • Mechanical Connectors Included Yes
  • Number of Cores 1
  • Power Cable Termination Voltage Class ≤ 72
  • Cross-Section Range 95 – 2500
  • Creepage Distance 2300
  • Power Cable Termination Insulation Diameter 30 – 86
  • Sheath Outside Diameter 110
  • Length (Installed) 1200
  • Application Type Outdoor
  • Design Specification IEC 60815
  • Power Cable Termination Product Availability AMERICAS
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
794450-097 Power Cable Terminations  1
GOST 13781.0.86, UHL 1 HD CENELEC 629.1 IEC 60502-4
  • Power Cable Termination Technology Heat Shrink
  • Mechanical Lug Included (Shield) No
  • Shelf Life No Limitation
  • Product Family Raychem
  • Number of Cores 1
  • Power Cable Termination Voltage Class 20.8/36(42)
  • Operating Temperature Range 0 – 95
  • Application Type Indoor
  • Design Specification HD CENELEC 629.1
A00805-061 Power Cable Terminations  1
GOST 13781.0.86, UHL 1 HD CENELEC 629.1 IEC 60502-4
  • Power Cable Termination Technology Heat Shrink
  • Cable Shield Style Wire Copper
  • Insulation Plastic (XLPE)
  • Number of Cores 1
  • Power Cable Termination Voltage Class ≤ 12
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) No
  • Cross-Section Range 95 – 240
  • Application Type Indoor
  • Design Specification GOST 13781.0.86,UHL 1
  • Power Cable Termination Product Availability CIS
  • Installation Instruction Bulgarian
A31452-070 Power Cable Terminations  1
GOST 13781.0.86, UHL 1 HD CENELEC 629.2
  • Power Cable Termination Technology Heat Shrink
  • Cable Shield Style Sheath Aluminium
  • Insulation Paper (PILC)
  • Termination Length 800
  • Number of Cores 3
  • Power Cable Termination Voltage Class ≤ 12
  • Mechanical Lug Included (M12, Conductor) Yes
  • Mechanical Lug Included (M16, Conductor) No
  • Armoring Steel Tape
  • Cross-Section Range 70 – 120
  • Application Type Indoor
  • Design Specification GOST 13781.0.86,UHL 1
  • Power Cable Termination Product Availability CIS
  • Installation Instruction Serbian
A41605-011 Power Cable Terminations  1
GOST 13781.0.86, UHL 1 HD CENELEC 629.1 IEC 60502-4
  • Power Cable Termination Technology Heat Shrink
  • Cable Shield Style Wire Copper
  • Insulation Plastic (XLPE)
  • Termination Length 1200
  • Number of Cores 3
  • Power Cable Termination Voltage Class ≤ 12
  • Mechanical Lug Included (M12, Conductor) Yes
  • Mechanical Lug Included (M16, Conductor) No
  • Cross-Section Range 120 – 240
  • Application Type Outdoor
  • Design Specification GOST 13781.0.86,UHL 1
  • Power Cable Termination Product Availability CIS
  • Installation Instruction English
BM3330-064 Power Cable Terminations  1
IEC 60840 IEC 62067 IEC 62271-203 IEC 62271-209
  • Power Cable Termination Technology Cold Applied
  • Power Cable Termination Voltage Class ≤ 245
  • Power Cable Termination Product Availability Worldwide
C29795-064 Power Cable Terminations  1
GOST 13781.0.86, UHL 1 HD CENELEC 629.1 IEC 60502-4
  • Power Cable Termination Technology Heat Shrink
  • Cable Shield Style Wire Copper
  • Insulation Plastic (XLPE)
  • Termination Length 1200
  • Number of Cores 3
  • Power Cable Termination Voltage Class ≤ 42
  • Mechanical Lug Included (M12, Conductor) Yes
  • Mechanical Lug Included (M16, Conductor) No
  • Cross-Section Range 50 – 120
  • Application Type Outdoor
  • Design Specification GOST 13781.0.86,UHL 1
  • Power Cable Termination Product Availability CIS
  • Installation Instruction Russian
CA6455-064 Power Cable Terminations  1
GOST 13781.0.86, UHL 1 HD CENELEC 629.1 IEC 60502-4
  • Power Cable Termination Technology Heat Shrink
  • Cable Shield Style Wire Copper
  • Insulation Plastic (XLPE)
  • Termination Length 1200
  • Number of Cores 3
  • Power Cable Termination Voltage Class ≤ 42
  • Mechanical Lug Included (M12, Conductor) Yes
  • Mechanical Lug Included (M16, Conductor) No
  • Cross-Section Range 50 – 120
  • Application Type Indoor
  • Design Specification GOST 13781.0.86,UHL 1
  • Power Cable Termination Product Availability CIS
  • Installation Instruction Russian