CAT-OXSU Power Cable Terminations  1
  • Technology Heat Shrink
  • Cable Shield Style Wire
  • Insulation Plastic
  • Sheds per Phase 1
  • Termination Length 300
  • Mechanical Connectors Included No
  • Mechanical Lug Included (Shield) 1
  • Number of Cores 1
  • Voltage Class ≤ 12
  • Mechanical Lug Included (M12, Conductor) 1
  • Mechanical Lug Included (M16, Conductor) 1
  • Cross-Section Range 10 – 25
  • Insulation Diameter 13.7 – 16.3
  • Shed Inside Diameter 120
  • Tail Length 450
  • Application Type Outdoor
  • Design Specification CENELEC HD 620 A2
  • Product Availability AMERICAS
  • Installation Instruction Danish
CAT-TFT-E Power Cable Terminations  1
  • Technology Cold Applied
  • Cable Shield Style JCN
  • Insulation Plastic
  • Sheds per Phase 3
  • Mechanical Connectors Included No
  • Shelf Life 3 Years
  • Number of Cores 1
  • Voltage Class ≤ 15
  • Application Type Indoor/Outdoor
  • Design Specification IEEE 48
  • Product Availability AMERICAS
CAT-HVT-Z Power Cable Terminations  1
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 1
  • Mechanical Connectors Included No
  • Number of Cores 1
  • Voltage Class ≤ 15
  • Application Type Indoor/Outdoor
  • Design Specification IEEE 48
  • Product Availability AMERICAS
CAT-IXSU Power Cable Terminations  1
  • Technology Heat Shrink
  • Cable Shield Style Wire
  • Insulation Plastic
  • Termination Length 300
  • Mechanical Connectors Included No
  • Mechanical Lug Included (Shield) 1
  • Shelf Life No Limitation
  • Number of Cores 1
  • Voltage Class ≤ 12
  • Mechanical Lug Included (M12, Conductor) 1
  • Mechanical Lug Included (M16, Conductor) 1
  • Cross-Section Range 10 – 25
  • Insulation Diameter 13.7 – 20.8
  • Tail Length 450
  • Application Type Indoor
  • Design Specification CENELEC HD 620 A2
  • Product Availability AMERICAS
  • Installation Instruction Czech
CAT-TFT-R Power Cable Terminations  1
  • Technology Cold Applied
  • Cable Shield Style None
  • Insulation Plastic
  • Sheds per Phase 3
  • Mechanical Connectors Included No
  • Shelf Life 3 Years
  • Number of Cores 1
  • Voltage Class ≤ 15
  • Application Type Indoor/Outdoor
  • Design Specification IEEE 48
  • Product Availability AMERICAS
CAT-CST Power Cable Terminations  1
GB/T 28427
  • Technology Cold Applied
  • Cable Shield Style CU-Tape
  • Insulation Plastic (XLPE)
  • Sheds per Phase 3
  • Termination Length 289
  • Mechanical Connectors Included No
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) No
  • Compression Lug Included (Shield) No
  • Number of Cores 1
  • Voltage Class ≤ 15
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) No
  • Armoring AL Wire
  • Cross-Section Range 25 – 35
  • Insulation Diameter 11.7 – 18
  • Shed Inside Diameter 135 – 165
  • Sheath Outside Diameter 34
  • Length (Installed) 1000
  • Application Type Outdoor
  • Design Specification HD CENELEC 629.1
  • Product Availability AMERICAS
  • Installation Instruction English
CAT-HVT-Z-J-SJ Power Cable Terminations  1
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 1
  • Mechanical Connectors Included No
  • Number of Cores 1
  • Voltage Class ≤ 15
  • Application Type Indoor/Outdoor
  • Design Specification IEEE 48
  • Product Availability AMERICAS
CAT-PHVS Power Cable Terminations  1
IEC 60840 IEC 62067 IEC 62271-203 IEC 62271-209
  • Technology Cold Applied
  • Cable Shield Style Adaptable
  • Insulation Polymeric
  • Mechanical Connectors Included Yes
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Product Family 748
  • Compression Lug Included (Shield) No
  • Number of Cores 1
  • Voltage Class ≤ 145
  • Armoring Adaptable
  • Cross-Section Range 95 – 2500
  • Insulation Diameter 34 - 108
  • Sheath Outside Diameter 0 - 120
  • Application Type Indoor
  • Design Specification IEC 60840
  • Product Availability Worldwide
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
CAT-PHVT Power Cable Terminations  1
IEC 60840 IEC 62067
  • Technology Cold Applied
  • Cable Shield Style Adaptable
  • Insulation Polymeric
  • Mechanical Connectors Included Yes
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Product Family 748
  • Compression Lug Included (Shield) No
  • Number of Cores 1
  • Voltage Class ≤ 145
  • Armoring Adaptable
  • Cross-Section Range 95 – 2500
  • Insulation Diameter 34 - 108
  • Sheath Outside Diameter 0 - 120
  • Application Type Indoor
  • Design Specification IEC 60840
  • Product Availability Worldwide
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
CAT-OHVT-C Power Cable Terminations  1
IEC 60815-1 IEC 60840 IEEE 48
  • Technology Cold Applied
  • Cable Shield Style Adaptable
  • Insulation XLPE
  • Mechanical Connectors Included Yes
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Product Family 748
  • Compression Lug Included (Shield) No
  • Number of Cores 1
  • Voltage Class ≤ 145
  • Cross-Section Range 95 – 2500
  • Insulation Diameter 34 – 97
  • Pollution Level (IEC 60815) I
  • Product Availability Worldwide
  • Minimum Order Quantity 1
CAT-EPKT Power Cable Terminations  1
  • Technology Heat Shrink
  • Cable Shield Style None
  • Insulation Plastic (XLPE)
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) No
  • Shelf Life No Limitation
  • Compression Lug Included (Shield) No
  • Number of Cores 4
  • Voltage Class ≤ 1
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) No
  • Cross-Section Range 4 – 35
  • Conductor Diameter 10 – 23
  • Application Type Indoor
  • Product Availability AMERICAS
  • Installation Instruction Bulgarian
CAT-OHVT-72H Power Cable Terminations  1
IEC 60815-1 IEC 60840
  • Technology Heat Shrink
  • Cable Shield Style AL-Wire & Al-Tape
  • Insulation Plastic (XLPE)
  • Mechanical Connectors Included Yes
  • Number of Cores 1
  • Voltage Class ≤ 72
  • Cross-Section Range 95 – 2500
  • Creepage Distance 2300
  • Insulation Diameter 30 – 86
  • Sheath Outside Diameter 110
  • Length (Installed) 1200
  • Application Type Outdoor
  • Design Specification IEC 60815
  • Product Availability AMERICAS
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
012839-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 2
  • Termination Length 550
  • Shelf Life No Limitation
  • Number of Cores 3
  • Voltage Class ≤ 42
  • Armoring Tape
  • Cross-Section Range 50 – 95
  • Insulation Diameter 30 – 35.1
  • Shed Inside Diameter 95
  • Application Type Indoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
041753-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 2
  • Termination Length 550
  • Shelf Life No Limitation
  • Number of Cores 1
  • Voltage Class ≤ 42
  • Cross-Section Range 120 – 185
  • Insulation Diameter 35 – 40
  • Shed Inside Diameter 115
  • Application Type Indoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
049092-013 Power Cable Terminations  1
GOST 13781.0.86, UHL 1 HD CENELEC 629.1 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Wire Copper
  • Insulation Plastic (XLPE)
  • Number of Cores 1
  • Voltage Class ≤ 12
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) Yes
  • Cross-Section Range 120 – 240
  • Application Type Indoor
  • Design Specification GOST 13781.0.86,UHL 1
  • Product Availability CIS
  • Installation Instruction Czech
049092-064 Power Cable Terminations  1
GOST 13781.0.86, UHL 1 HD CENELEC 629.1 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Wire Copper
  • Insulation Plastic (XLPE)
  • Number of Cores 1
  • Voltage Class ≤ 12
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) Yes
  • Cross-Section Range 120 – 240
  • Application Type Indoor
  • Design Specification GOST 13781.0.86,UHL 1
  • Product Availability CIS
  • Installation Instruction Russian
049092-097 Power Cable Terminations  1
GOST 13781.0.86, UHL 1 HD CENELEC 629.1 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Wire Copper
  • Insulation Plastic (XLPE)
  • Number of Cores 1
  • Voltage Class ≤ 12
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) Yes
  • Cross-Section Range 120 – 240
  • Application Type Indoor
  • Design Specification GOST 13781.0.86,UHL 1
  • Product Availability CIS
  • Installation Instruction Russian
052121-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 4
  • Termination Length 750
  • Shelf Life No Limitation
  • Number of Cores 3
  • Voltage Class ≤ 42
  • Armoring Tape
  • Cross-Section Range 240 – 500
  • Insulation Diameter 40 – 50.3
  • Shed Inside Diameter 135
  • Application Type Outdoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
062981-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 2
  • Termination Length 550
  • Shelf Life No Limitation
  • Number of Cores 1
  • Voltage Class ≤ 42
  • Cross-Section Range 240 – 500
  • Insulation Diameter 40 – 50.3
  • Shed Inside Diameter 135
  • Application Type Indoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
065211-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Termination Length 400
  • Shelf Life No Limitation
  • Number of Cores 1
  • Voltage Class ≤ 17.5
  • Cross-Section Range 95 – 240
  • Insulation Diameter 21.6 – 30
  • Application Type Indoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1