• English
Home > Products > Relays, Switches and Sensors > Relays > Product Feature Selector

High Performance Solid State Relays Product Feature Selector

Government/Industry Qualification
Output Current Rating (A)
  • 2
  • Common to all 11 remaining products
Insulation - Initial Dielectric Between Contacts and Coil (V rms)
Input Voltage (VDC)
  • 3.8 – 32
  • Common to all 11 remaining products
Input Current Max. @ 5Vdc (VDC)
  • Click here to clear this feature... 15
Screening Level Screening Level Explanation
  • W (1)
  • Y (10)
Termination Type
Mounting Options
  • PC Board
  • Common to all 11 remaining products
Additional Features
Lead Free Solder Processes Lead Free Solder Processes Explanation
Brand
Showing 1 - 11 of 11 Matching Products

Product Line Information

Export To Excel

Part Differing Features
Click here for product details for DS13-1002

  • Government/Industry Qualification = No
  • Output Voltage Rating (DC Relays) = 60 VDC
  • Insulation - Initial Dielectric Between Contacts and Coil = 1000 V rms
  • Screening Level = Y
  • Termination Type = Through Hole
  • With Short Circuit Protection/Control Status
  • CII
Not EU RoHS or ELV Compliant, Not applicable for solder process capability
Click here for product details for JDS9-1Y

  • Government/Industry Qualification = Yes
  • M28750/9-001Y
  • Output Voltage Rating (AC Relays) = 250 V rms
  • Insulation - Initial Dielectric Between Contacts and Coil = 1500 V rms
  • Screening Level = Y
  • Termination Type = Through Hole
  • Additional Features = None
  • CII
Not EU RoHS or ELV Compliant, Not solder process capable
Click here for product details for 3-1617776-7

  • Government/Industry Qualification = No
  • Output Voltage Rating (DC Relays) = 60 VDC
  • Insulation - Initial Dielectric Between Contacts and Coil = 1000 V rms
  • Screening Level = Y
  • Termination Type = Surface Mount
  • With Short Circuit Protection
  • CII
Not EU RoHS or ELV Compliant, Not applicable for solder process capability
Click here for product details for DS11-1000

  • Government/Industry Qualification = No
  • Output Voltage Rating (DC Relays) = 60 VDC
  • Insulation - Initial Dielectric Between Contacts and Coil = 1000 V rms
  • Screening Level = Y
  • Termination Type = Through Hole
  • With Short Circuit Protection
  • CII
Not EU RoHS or ELV Compliant, Not applicable for solder process capability
Click here for product details for DS11-1002

  • Government/Industry Qualification = No
  • Output Voltage Rating (DC Relays) = 60 VDC
  • Insulation - Initial Dielectric Between Contacts and Coil = 1000 V rms
  • Screening Level = Y
  • Termination Type = Through Hole
  • With Short Circuit Protection/Switch Status
  • CII
Not EU RoHS or ELV Compliant, Not applicable for solder process capability
Click here for product details for DS11-1Y

  • Government/Industry Qualification = No
  • Output Voltage Rating (DC Relays) = 60 VDC
  • Insulation - Initial Dielectric Between Contacts and Coil = 1000 V rms
  • Screening Level = Y
  • Termination Type = Through Hole
  • Additional Features = None
  • CII
Not EU RoHS or ELV Compliant, Not applicable for solder process capability
Click here for product details for DS13-1000

  • Government/Industry Qualification = No
  • Output Voltage Rating (DC Relays) = 60 VDC
  • Insulation - Initial Dielectric Between Contacts and Coil = 1000 V rms
  • Screening Level = Y
  • Termination Type = Through Hole
  • With Short Circuit Protection
  • CII
Not EU RoHS or ELV Compliant, Not applicable for solder process capability
Click here for product details for DS13-1000S

  • Government/Industry Qualification = No
  • Output Voltage Rating (DC Relays) = 60 VDC
  • Insulation - Initial Dielectric Between Contacts and Coil = 1000 V rms
  • Screening Level = Y
  • Termination Type = Surface Mount
  • With Short Circuit Protection
  • CII
Not EU RoHS or ELV Compliant, Not applicable for solder process capability
Click here for product details for DS9-1W

  • Government/Industry Qualification = No
  • Output Voltage Rating (AC Relays) = 250 V rms
  • Insulation - Initial Dielectric Between Contacts and Coil = 1500 V rms
  • Screening Level = W
  • Termination Type = Through Hole
  • Additional Features = None
  • Kilovac
Not EU RoHS or ELV Compliant, Not applicable for solder process capability
Click here for product details for DS11-1003

  • Government/Industry Qualification = No
  • Output Voltage Rating (DC Relays) = 60 VDC
  • Insulation - Initial Dielectric Between Contacts and Coil = 1000 V rms
  • Screening Level = Y
  • Termination Type = Through Hole
  • With Short Circuit Protection/Trip Status
  • CII
Not reviewed for RoHS Compliance, Not reviewed for solder process capability
Click here for product details for DS13-1002S

  • Government/Industry Qualification = No
  • Output Voltage Rating (DC Relays) = 60 VDC
  • Insulation - Initial Dielectric Between Contacts and Coil = 1000 V rms
  • Screening Level = Y
  • Termination Type = Surface Mount
  • With Short Circuit Protection/Control Status
  • CII
Not reviewed for RoHS Compliance, Not reviewed for solder process capability
Showing 1 - 11 of 11 Matching Products

Product Line Information

Export To Excel

This list is temporary. The list will not be viewable on another computer and will be deleted within 30 days.

If your browser cookies are cleared, your temporary list will be lost. You can save this list and get all of the My Part List features by becoming a registered user of the TE web site.