CF6575-000 Power Cable Terminations  1
IEC 60502-4
  • Technology Cold Applied
  • Cable Shield Style Tape
  • Termination Length 349
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) No
  • Number of Cores 3
  • Voltage Class ≤ 17.5
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) No
  • Armoring Steel Tape
  • Cross-Section Range 120 – 400
  • Insulation Diameter 23 – 35
  • Length (Installed) 1000
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) II
  • Design Specification IEC 60502-4
  • Product Availability China
CF6576-000 Power Cable Terminations  1
IEC 60502-4
  • Technology Cold Applied
  • Cable Shield Style Tape
  • Insulation XLPE
  • Termination Length 349
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) No
  • Number of Cores 3
  • Voltage Class ≤ 17.5
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) No
  • Armoring Steel Tape
  • Cross-Section Range 25 – 95
  • Insulation Diameter 16 – 23
  • Length (Installed) 1000
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) II
  • Design Specification IEC 60502-4
  • Product Availability China
CL4256-000 Power Cable Terminations  1
IEC 60502-4
  • Technology Cold Applied
  • Cable Shield Style Tape/Wire
  • Termination Length 349
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) No
  • Number of Cores 1
  • Voltage Class ≤ 17.5
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) No
  • Cross-Section Range 25 – 95
  • Insulation Diameter 16 – 23
  • Length (Installed) 350
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) II
  • Design Specification IEC 60502-4
  • Product Availability China
CL4257-000 Power Cable Terminations  1
IEC 60502-4
  • Technology Cold Applied
  • Cable Shield Style Tape/Wire
  • Termination Length 349
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) No
  • Number of Cores 1
  • Voltage Class ≤ 17.5
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) No
  • Cross-Section Range 120 – 630
  • Insulation Diameter 23 – 35
  • Length (Installed) 350
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) II
  • Design Specification IEC 60502-4
  • Product Availability China
CM0741-000 Power Cable Terminations  1
IEC 60502-4
  • Technology Cold Applied
  • Cable Shield Style Tape
  • Sheds per Phase 4
  • Termination Length 500
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) No
  • Number of Cores 3
  • Voltage Class ≤ 42
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) No
  • Armoring Steel Tape
  • Cross-Section Range 50 – 95
  • Insulation Diameter 30 – 35
  • Shed Diameter 97 – 105
  • Length (Installed) 1150
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) II
  • Design Specification IEC 60502-4
  • Product Availability China
CM0742-000 Power Cable Terminations  1
IEC 60502-4
  • Technology Cold Applied
  • Cable Shield Style Tape/Wire
  • Sheds per Phase 4
  • Termination Length 500
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) No
  • Number of Cores 1
  • Voltage Class ≤ 42
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) No
  • Cross-Section Range 50 – 95
  • Insulation Diameter 30 – 35
  • Shed Diameter 97 – 105
  • Length (Installed) 560
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) II
  • Design Specification IEC 60502-4
  • Product Availability China
CM0743-000 Power Cable Terminations  1
IEC 60502-4
  • Technology Cold Applied
  • Cable Shield Style Tape
  • Sheds per Phase 4
  • Termination Length 500
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) No
  • Number of Cores 3
  • Voltage Class ≤ 42
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) No
  • Armoring Steel Tape
  • Cross-Section Range 120 – 400
  • Insulation Diameter 35 – 45
  • Shed Diameter 97 – 105
  • Length (Installed) 1150
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) II
  • Design Specification IEC 60502-4
  • Product Availability China
CM0744-000 Power Cable Terminations  1
IEC 60502-4
  • Technology Cold Applied
  • Cable Shield Style Tape/Wire
  • Sheds per Phase 4
  • Termination Length 500
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) No
  • Number of Cores 1
  • Voltage Class ≤ 42
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) No
  • Cross-Section Range 120 – 400
  • Insulation Diameter 35 – 45
  • Shed Diameter 97 – 105
  • Length (Installed) 560
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) II
  • Design Specification IEC 60502-4
  • Product Availability China