CAT-SCH691-T1 Power Relays  1
  • Insulation Initial Dielectric Between Contacts & Coil 2500
  • Contact Limiting Continuous Current 20
  • Insulation Creepage Between Contact & Coil 6.36
  • Contact Limiting Making Current 20
  • Insulation Initial Resistance 1000
  • Contact Limiting Short-Time Current 20
  • Insulation Initial Dielectric Between Open Contacts 1500
  • Insulation Creepage Class 5.5 – 8
  • Insulation Initial Dielectric Between Coil & Contact Class 1500 – 2500
  • Insulation Special Features 6000V Initial Surge Withstand Voltage between Contacts & Coil
  • Weight 33
  • Length 32.5
  • Insulation Clearance Class 2.5 – 4
  • Width 27.4
  • Height 27.9
  • Width Class (Mechanical) 25 – 30
  • Insulation Clearance Between Contact & Coil 3.18
  • Height Class (Mechanical) 25 – 30
  • Length Class (Mechanical) 30 – 35
  • Environmental Ambient Temperature Class 70 – 85
  • Environmental Ambient Temperature (Max) 85
CAT-AX41-IM11B Signal Relays  1
  • Product Type Relay
  • Relay Type IM Relay
  • Coil Type Monostable
  • Contact Limiting Continuous Current 2
  • Coil Resistance 180
  • Contact Limiting Making Current 2
  • Insulation Initial Resistance 1000000
  • Insulation Initial Dielectric Between Adjacent Contacts 1000
  • Insulation Initial Dielectric Between Coil/Contact Class 1500 V – 2500 VA
  • Insulation Initial Dielectric Between Contacts and Coil 1800
  • Contact Limiting Short-Time Current 2
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Coil Power Rating Class 50 – 300 mW
  • Voltage Standing Wave Ration (HF Parameter) 1.07 @ 100MHz
  • Actuating System DC
  • Insulation Special Features 2500V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Current Class 0 – 2 A
  • Contact Plating Material Gold
  • Contact Special Features Bifurcated/Twin Contacts
  • Dimensions (L x W x H) (Approximate) 10 x 6 x 5.65
  • Width Class (Mechanical) 0 – 6 mm
  • Width 6
  • Height Class (Mechanical) 0 – 6 mm
  • Length Class (Mechanical) 0 – 10 mm
  • Height 5.6
  • Environmental Ambient Temperature (Max) 85
  • Environmental Ambient Temperature Class 70 – 85°C
  • Packaging Method Reel
  • Additional Features Gull Wing
CAT-SCH691-R819A Power Relays  1
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 16
  • Insulation Creepage Between Contact & Coil 10
  • Contact Limiting Making Current 165
  • Contact Limiting Short-Time Current 16
  • Insulation Initial Dielectric Between Open Contacts 1250
  • Insulation Creepage Class 8
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Insulation Special Features Tracking Index of Relay Base PTI250V
  • Weight 14
  • Contact Special Features W Pre-Make Contact
  • Length 29
  • Insulation Clearance Class 8
  • Width 12.7
  • Height 16
  • Width Class (Mechanical) 12 – 16
  • Insulation Clearance Between Contact & Coil 10
  • Height Class (Mechanical) 15 – 16
  • Length Class (Mechanical) 25 – 30
  • Environmental Ambient Temperature Class 70 – 85
  • Environmental Ambient Temperature (Max) 85
CAT-SCH691-R997 Power Relays  1
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 16
  • Insulation Creepage Between Contact & Coil 10
  • Contact Limiting Making Current 30
  • Contact Limiting Short-Time Current 16
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Creepage Class 8
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Insulation Special Features Tracking Index of Relay Base PTI250
  • Weight 10
  • Length 29
  • Insulation Clearance Class 8
  • Width 12.7
  • Height 15.7
  • Width Class (Mechanical) 12 – 16
  • Insulation Clearance Between Contact & Coil 10
  • Height Class (Mechanical) 15 – 16
  • Length Class (Mechanical) 25 – 30
  • Environmental Ambient Temperature Class 85 – 105
  • Environmental Ambient Temperature (Max) 105
CAT-SCH691-R819B Power Relays  1
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 16
  • Insulation Creepage Between Contact & Coil 6
  • Contact Limiting Making Current 16
  • Contact Limiting Short-Time Current 16
  • Insulation Initial Dielectric Between Open Contacts 1250
  • Insulation Creepage Class 5.5 – 8
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Insulation Special Features Tracking Index of Relay Base PTI250
  • Weight 11
  • Contact Special Features Flip-Flop Contacts
  • Length 29.1
  • Insulation Clearance Class 5 – 8
  • Width 12.7
  • Height 16
  • Width Class (Mechanical) 12 – 16
  • Insulation Clearance Between Contact & Coil 6
  • Height Class (Mechanical) 15 – 16
  • Length Class (Mechanical) 25 – 30
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 70
CAT-P851-T1 Power Relays  1
  • Insulation Initial Dielectric Between Contacts & Coil 2500
  • Insulation Initial Dielectric Between Open Contacts 4000
  • Weight 18
  • Relay Termination Type Printed Circuit Terminals
  • Dimensions (L x W x H) (Approximate) 29 x 21.5 x 15.7
  • Width 21.5
  • Length 29
  • Height 15.7
  • Width Class (Mechanical) 20 – 25
  • Height Class (Mechanical) 15 – 16
  • Length Class (Mechanical) 25 – 30
  • Environmental Ambient Temperature (Max) 105
K70C881 High Voltage Relays
  • RF Rated No
  • Product Type Relay
  • Relay Type High Voltage
  • Economizer Without
  • Power Switching Make Only
  • Voltage (Max) 1800
  • Coil Voltage Rating 26.5
  • Coil Resistance 75
  • Contact Arrangement 1 Form A, SPST-NO, 1 NO
  • Contact Current Rating 10
  • High Voltage Connection (Coil) Turret Terminals
  • High Voltage Connection (Power) Flying Leads
  • Termination Style Turret Terminals
  • Mounting Type Threaded
4-1423161-3 Time Delay Relays  1
  • Relay Type Time Delay
  • Product Type Relay
  • Product Category Electromechanical Relays
  • Multiple Timing Ranges Without
  • Input Voltage 96
  • Actuating System DC
  • Type of Control Knob
  • Contact Current Rating 10A@240VAC
  • Delay Time 2 – 20 seconds
  • Contact Arrangement 4 Form C, 4PDT, 4 C/O
  • Termination Type Screw Terminal
  • Mounting Type Mounting Bracket
  • Dimensions (L x W x H) (Approximate) 147.82 x 82.55 x 84.32
  • Operating Temperature Range -30 – 75
  • Mode of Operation On-Delay
  • Option Dust-Tight Gasketing
  • Repeatability (Max) ±10%
5-1423161-2 Time Delay Relays  1
  • Relay Type Time Delay
  • Product Type Relay
  • Product Category Electromechanical Relays
  • Multiple Timing Ranges Without
  • Input Voltage 24
  • Actuating System DC
  • Type of Control Knob
  • Contact Current Rating 10A@240VAC
  • Delay Time 3 – 30 minutes
  • Contact Arrangement 4 Form C, 4PDT, 4 C/O
  • Termination Type Screw Terminal
  • Mounting Type Mounting Bracket
  • Dimensions (L x W x H) (Approximate) 147.82 x 82.55 x 84.32
  • Operating Temperature Range -30 – 75
  • Mode of Operation On-Delay
  • Repeatability (Max) ±10%
7022RHA2 Time Delay Relays  1
  • Relay Type Time Delay
  • Product Type Relay
  • Product Category Electromechanical Relays
  • Enclosure Type Hermetic Sealed Metallic
  • Multiple Timing Ranges Without
  • Input Voltage 60
  • Type of Control Knob
  • Contact Current Rating 10A@240VAC
  • Delay Time 3 – 30 minutes
  • Contact Arrangement 2 Form C, DPDT, 2 C/O
  • Termination Type Double Quick Connect Terminal
  • Mounting Type Mounting Bracket
  • Dimensions (L x W x H) (Approximate) 114.8 x 65.3 x 71.9
  • Operating Temperature Range -30 – 75
  • Mode of Operation Off-Delay
  • Repeatability (Max) ±10%
K81BB57 High Voltage Relays
  • RF Rated No
  • Product Type Relay
  • Relay Type High Voltage
  • Economizer Without
  • Power Switching Make Only
  • Voltage (Max) 1800
  • Coil Voltage Rating 26.5
  • Coil Resistance 290
  • Contact Arrangement 1 Form B, SPST-NC, 1 N/C
  • Contact Current Rating 10
  • High Voltage Connection (Coil) Stud Terminals
  • High Voltage Connection (Power) Stud Terminals
  • Termination Style Stud Terminals
  • Mounting Type Panel
FCA-210-BZ2 Mid-Range Relays
  • Terminal Configuration Solder Pins
  • Product Type Relay
  • Relay Type Military/Aerospace Mid-Range
  • Enclosure Type Hermetically Sealed
  • Coil Suppression Diode Without
  • Coil Voltage Rating 12
  • Coil Resistance 80
  • Back EMF Suppression Without
  • Vibration 30G's, 33 – 3000Hz
  • Coil Magnetic System Polarized, Monostable
  • Actuating System DC
  • Shock 200G's, 6ms
  • Contact Arrangement 2 Form C, DPDT, 2 C/O
  • Auxiliary Contacts Without
  • Terminal Plating Tin-Lead
  • Contact Current Rating 10
  • Contact Base Material Silver Cadmium Oxide
  • Mounting Type No Brackets
  • Operating Temperature Range -70 – 125
7022AC Time Delay Relays  1
  • Relay Type Time Delay
  • Product Type Relay
  • Product Category Electromechanical Relays
  • Multiple Timing Ranges Without
  • Input Voltage 110
  • Timing Range (Off-Time) 1.5 – 15
  • Actuating System AC
  • Type of Control Knob
  • Delay Time 1.5 – 15 seconds
  • Contact Arrangement 2 Form C, DPDT, 2 C/O
  • Termination Type Screw Terminals
  • Mounting Type Panel Mount
  • Dimensions (L x W x H) (Approximate) 114.8 x 65.3 x 71.9
  • Operating Temperature Range -30 – 75
  • Mode of Operation Off-Delay
  • Repeatability (Max) ±5%
7022AB Time Delay Relays  1
  • Relay Type Time Delay
  • Product Type Relay
  • Product Category Electromechanical Relays
  • Multiple Timing Ranges Without
  • Input Voltage 110
  • Timing Range (Off-Time) .5 – 5
  • Actuating System AC
  • Type of Control Knob
  • Delay Time .5 – 5 seconds
  • Contact Arrangement 2 Form C, DPDT, 2 C/O
  • Termination Type Screw Terminals
  • Mounting Type Panel Mount
  • Dimensions (L x W x H) (Approximate) 114.8 x 65.3 x 71.9
  • Operating Temperature Range -30 – 75
  • Mode of Operation Off-Delay
  • Repeatability (Max) ±5%
H-14 High Voltage Relays
  • RF Rated Yes
  • Product Type Relay
  • Relay Type High Voltage
  • Economizer Without
  • Power Switching Make Only
  • Voltage (Max) 1800
  • Coil Voltage Rating 26.5
  • Coil Resistance 120
  • Contact Arrangement 1 Form A, SPST-NO, 1 NO
  • Contact Current Rating 30
  • High Voltage Connection (Coil) Turret Terminals
  • High Voltage Connection (Power) High Voltage Tabs
  • Termination Style Turret Terminals
  • Mounting Type Threaded
H-26 High Voltage Relays
  • RF Rated Yes
  • Product Type Relay
  • Relay Type High Voltage
  • Economizer Without
  • Power Switching Make Only
  • Voltage (Max) 1800
  • Coil Voltage Rating 26.5
  • Coil Resistance 130
  • Contact Arrangement 1 Form A, SPST-NO, 1 NO
  • Contact Current Rating 30
  • High Voltage Connection (Coil) Turret Terminals
  • High Voltage Connection (Power) High Voltage Tabs
  • Termination Style Turret Terminals
  • Mounting Type Threaded
  • RF Rated No
  • Product Type Contactor
  • Relay Type High Voltage
  • Economizer Without
  • Coil Voltage Rating 24
  • Coil Voltage Rating 24
  • Contact Arrangement 1 Form Y, SPST-NC
  • Contact Current Rating 500
  • High Voltage Connection (Coil) Flying Leads
  • High Voltage Connection (Power) Screw Terminals
  • Termination Style Stud Terminals
  • Mounting Type Bottom
7012AE Time Delay Relays  1
  • Relay Type Time Delay
  • Product Type Relay
  • Product Category Electromechanical Relays
  • Multiple Timing Ranges Without
  • Input Voltage 110
  • Timing Range (Off-Time) 20 – 200
  • Actuating System AC
  • Type of Control Knob
  • Delay Time 20 – 200 seconds
  • Contact Arrangement 2 Form C, DPDT, 2 C/O
  • Termination Type Screw Terminals
  • Mounting Type Panel Mount
  • Dimensions (L x W x H) (Approximate) 114.8 x 65.3 x 71.9
  • Operating Temperature Range -30 – 75
  • Mode of Operation On-Delay
  • Option Auxiliary Switch - Two Step Timing
  • Repeatability (Max) ±5%
7022PD Time Delay Relays  1
  • Relay Type Time Delay
  • Product Type Relay
  • Product Category Electromechanical Relays
  • Multiple Timing Ranges Without
  • Input Voltage 125
  • Timing Range (Off-Time) 5 – 50
  • Actuating System DC
  • Type of Control Knob
  • Delay Time 5 – 50 seconds
  • Contact Arrangement 2 Form C, DPDT, 2 C/O
  • Termination Type Screw Terminals
  • Mounting Type Panel Mount
  • Dimensions (L x W x H) (Approximate) 114.8 x 65.3 x 71.9
  • Operating Temperature Range -30 – 75
  • Mode of Operation Off-Delay
  • Repeatability (Max) ±5%
7022AE Time Delay Relays  1
  • Relay Type Time Delay
  • Product Type Relay
  • Product Category Electromechanical Relays
  • Multiple Timing Ranges Without
  • Input Voltage 110
  • Timing Range (Off-Time) 20 – 200
  • Actuating System AC
  • Type of Control Knob
  • Delay Time 20 – 200 seconds
  • Contact Arrangement 2 Form C, DPDT, 2 C/O
  • Termination Type Screw Terminals
  • Mounting Type Panel Mount
  • Dimensions (L x W x H) (Approximate) 114.8 x 65.3 x 71.9
  • Operating Temperature Range -30 – 75
  • Mode of Operation Off-Delay
  • Repeatability (Max) ±5%