Contact us to request more information about this model, including customization options

Contact Us

This is ideal for applications which may experience rough handling or in situations where the accelerometer must survive a high initial overload in order to make a low g measurement.


  • Miniature Triaxial Design 
  • DC Response, Critically Damped 
  • Broad Temperature Range
  • Low Weight
  • Static and Dynamic Measurement
  • Frequency Response through 3000 Hz
  • ±1% Non-Linearity
  • -40°C to +120°C Operating Range
  • 10,000g Over-range Protection



Please review product documents or contact us for the latest agency approval information.  

Product Type Features

  • Sensor Type  DC Response Plug & Play Accelerometers

  • Accelerometer Type  MEMS DC

Electrical Characteristics

  • Zero Acceleration Output (mV) ±15

  • Full Scale Output Voltage (VDC) ±.1

  • Excitation Voltage (VDC) 2 – 15

  • Electrical Connection  Integral Cable

Signal Characteristics

  • Frequency Response (Hz) 0-250 to 0-3000

Body Features

  • Number of Axes  3

  • Material  Stainless Steel

  • Weight 6 g [ .21 oz ]

Mechanical Attachment

  • Mounting Type  Adhesive, Screw

Usage Conditions

  • Operating Temperature -40 – 120 °C [ -40 – 248 °F ]


  • Overall Acceleration Range (±) (g) 5 – 2500

  • Acceleration Range (±) (g) 5, 10, 25, 50, 100, 250, 500, 1000, 2500

  • Sensitivity Range  .1 – 12 mV/g

  • Sensitivity  .1 mV/g, .25 mV/g, .5 mV/g, .75 mV/g, 1.5 mV/g, 2.25 mV/g, 3 mV/g, 6 mV/g, 7.5 mV/g

  • Nonlinearity (%FSO) ±1

Related Materials

Terms and Conditions

Please carefully read the disclaimer before using any of this data.
Your use of this data constitutes your acceptance of the terms and conditions set forth below. If you do not agree to those terms and conditions, please click on the I Disagree link.

This information has been provided to you free of charge for your use but remains the sole property of Tyco Electronics Corporation ("TE"). While TE has used reasonable efforts to ensure its accuracy, TE does not guarantee that it is error-free, nor makes any other representation, warranty, or guarantee that the information is completely accurate or up-to-date. In many cases, the CAD data has been simplified to remove proprietary detail while maintaining critical interface geometric detail for use by customers. TE expressly disclaims all implied warranties regarding this information, including but not limited to any implied warranties or merchantability or fitness for a particular purpose.