1810DDBX Protective Relays
  • Protection Function Paralleling, Double Dead Bus (Either Bus Dead)
  • Time Delay Without
  • Product Type Relay
  • Relay Type Protective Relay
  • Input Voltage 120
  • Actuating System AC
  • Frequency Adjustment 50 – 500
  • Contact Arrangement 1 Form A, SPST-NO, 1 NO
  • Contact Current Rating 5
  • Contact Arrangement (Additional Output) 1 Form B, SPST-NC, 1 N/C
  • Dimensions (L x W x H) (Approximate) 117.47 x 123.82 x 76.2
  • Operating Temperature Range -25 – 70
  • Mode of Operation Adjustable Pick-Up
1810X Protective Relays
  • Protection Function Paralleling
  • Time Delay Without
  • Product Type Relay
  • Relay Type Protective Relay
  • Input Voltage 120
  • Actuating System AC
  • Frequency Adjustment 50 – 500
  • Contact Arrangement 1 Form A, SPST-NO, 1 NO
  • Contact Current Rating 5
  • Contact Arrangement (Additional Output) 1 Form B, SPST-NC, 1 N/C
  • Dimensions (L x W x H) (Approximate) 117.47 x 123.82 x 76.2
  • Operating Temperature Range -25 – 70
  • Mode of Operation Adjustable Pick-Up
20-050-2X Protective Relays
  • Protection Function Over/Underfrequency
  • Time Delay Without
  • Phase Single
  • Product Type Relay
  • Relay Type Protective Relay
  • Input Voltage 120
  • Actuating System AC
  • Frequency Adjustment 55 – 66
  • Type of Control Potentiometer Adjustable
  • Contact Arrangement 1 Form A, SPST-NO, 1 NO
  • Contact Current Rating 5
  • Contact Arrangement (Additional Output) 1 Form B, SPST-NC, 1 N/C
  • Dimensions (L x W x H) (Approximate) 88.9 x 76.2 x 80.822
  • Operating Temperature Range -20 – 85
D100X Protective Relays
  • Protection Function Undervoltage, Close Differential
  • Time Delay Without
  • Phase Single
  • Product Type Relay
  • Relay Type Protective Relay
  • Input Voltage 120
  • Actuating System AC
  • Frequency Adjustment 50 – 400
  • Contact Arrangement 1 Form C, SPDT, 1 C/O
  • Contact Current Rating 5
  • Contact Arrangement (Additional Output) None
  • Dimensions (L x W x H) (Approximate) 76.2 x 88.9 x 63.5
  • Operating Temperature Range -20 – 85
  • Mode of Operation Adjustable Pick-Up & Adjustable Drop-Out
WD2759-002 Protective Relays
  • Protection Function Over/Undervoltage
  • Time Delay Without
  • Phase Single or Three
  • Product Type Relay
  • Relay Type Protective Relay
  • Input Voltage 13.5 – 32
  • Actuating System DC
  • Frequency Adjustment 40 – 400
  • Contact Arrangement 2 Form C, DPDT, 2 C/O
  • Contact Arrangement (Additional Output) None
  • Mounting Type Snap-On DIN Rail
  • Dimensions (L x W x H) (Approximate) 73 x 75 x 112
  • Operating Temperature Range -40 – 60
WD2759-003 Protective Relays
  • Protection Function Over/Undervoltage
  • Time Delay Without
  • Phase Single or Three
  • Product Type Relay
  • Relay Type Protective Relay
  • Input Voltage 100 – 200
  • Input Voltage 100 – 140
  • Actuating System AC/DC
  • Frequency Adjustment 40 – 400
  • Contact Arrangement 2 Form C, DPDT, 2 C/O
  • Contact Arrangement (Additional Output) None
  • Mounting Type Snap-On DIN Rail
  • Dimensions (L x W x H) (Approximate) 73 x 75 x 112
  • Operating Temperature Range -40 – 60
1-1618108-5 Protective Relays  1
  • Time Delay Without
  • Product Type Relay
  • Relay Type Protective Relay
  • Input Voltage 120
  • Contact Arrangement 1 N.C & 1 N.O
  • Contact Current Rating 5
  • Mounting Type Flange Panel Mount
1001X Protective Relays
  • Protection Function Phase Failure, Voltage Sensitive
  • Time Delay Without
  • Phase Three
  • Product Type Relay
  • Relay Type Protective Relay
  • Input Voltage 120
  • Actuating System AC
  • Contact Arrangement 1 Form A, SPST-NO, 1 NO
  • Contact Current Rating 10
  • Contact Arrangement (Additional Output) None
  • Operating Temperature Range -40 – 70
1002X Protective Relays
  • Protection Function Phase Failure, Voltage Sensitive
  • Time Delay Without
  • Phase Three
  • Product Type Relay
  • Relay Type Protective Relay
  • Input Voltage 230
  • Actuating System AC
  • Contact Arrangement 1 Form A, SPST-NO, 1 NO
  • Contact Current Rating 10
  • Contact Arrangement (Additional Output) None
  • Operating Temperature Range -40 – 70
1004X Protective Relays
  • Protection Function Phase Failure, Voltage Sensitive
  • Time Delay Without
  • Phase Three
  • Product Type Relay
  • Relay Type Protective Relay
  • Input Voltage 460
  • Actuating System AC
  • Contact Arrangement 1 Form A, SPST-NO, 1 NO
  • Contact Current Rating 10
  • Contact Arrangement (Additional Output) None
  • Operating Temperature Range -40 – 70