CAT-RPIT Dead Break Connections  1
HD CENELEC 629.1
  • Product Family RPIT
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Marine-Offshore-Shipbuilding Certified No
  • Non-Toxic & Non-Corrosive Emission Yes
  • Emission Free Yes
  • UL Rating No
  • Design Specification HD629.1-S2
CAT-T3437-H857 Standard Labels  1
  • Recommended Printer Ribbon See Printer Ribbon Matrix
  • Printer Technology Thermal Transfer
  • Recommended Printer See Printer Ribbon Matrix
  • Number of Labels Across 1
  • Packaging Quantity 1000
CAT-T3437-N8792 Standard Labels  1
  • Recommended Printer Ribbon See Printer Ribbon Matrix
  • Printer Technology Non-Printable
  • Recommended Printer See Printer Ribbon Matrix
  • Number of Labels Across 1
  • Packaging Quantity 1
CAT-T3437-T7899 Standard Labels  1
  • Recommended Printer Ribbon See Printer Ribbon Matrix
  • Printer Technology Thermal Transfer
  • Recommended Printer See Printer Ribbon Matrix
  • Number of Labels Across 1
  • Packaging Quantity 1
CAT-T3437-T7899A Standard Labels  1
  • Recommended Printer Ribbon See Printer Ribbon Matrix
  • Printer Technology Thermal Transfer
  • Recommended Printer See Printer Ribbon Matrix
  • Number of Labels Across 1
  • Packaging Quantity 1
CAT-OXSU Power Cable Terminations  1
HD CENELEC 620 A2 HD CENELEC 629.1 IEC 60502-4
  • Application Type Outdoor
  • Design Specification CENELEC HD 620 A2
CAT-IXSU Power Cable Terminations  1
HD CENELEC 620 A2 HD CENELEC 629.1 IEC 60502-4
  • Shelf Life No Limitation
  • Application Type Indoor
  • Design Specification CENELEC HD 620 A2
CAT-MWTM Power Cable Tubing & Accessories  1
HD CENELEC 631.2 IEC 60684-3-216 IEC 60684-3-246 IEC 60684-3-247
  • Color Black
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Low Smoke Emission Yes
  • Marine-Offshore-Shipbuilding Certified Yes
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Non-Toxic & Non-Corrosive Emission Yes
  • Emission Free No
  • Free of Lead, Cadmium, Heavy Metals Yes
  • CSA Certified No
  • Standards IEC 60684-3-214, IEC 60684-3-246, IEC 60684-3-247, HD631.2
  • UL Rating No
  • Other Colors Available No
CAT-RSTI Dead Break Connections  1
HD CENELEC 629.1
  • Application Type T-Connector
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Marine-Offshore-Shipbuilding Certified Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Emission Free Yes
  • UL Rating No
  • Design Specification HD629.1-S2
CAT-WCSM Power Cable Tubing & Accessories  1
HD CENELEC 631.2 IEC 60684-3-216 IEC 60684-3-246 IEC 60684-3-247
  • Coating Style Inline
  • Color Black
  • Mechanical Resistance Against Mechanical Impact or Damage
  • Low Smoke Emission Yes
  • Marine-Offshore-Shipbuilding Certified Yes
  • Thermal Resistance Applicable for Low Temperatures, Applicable for High Temperatures, Flame-Retardant
  • Non-Toxic & Non-Corrosive Emission Yes
  • Emission Free No
  • Free of Lead, Cadmium, Heavy Metals Yes
  • CSA Certified Yes
  • Standards IEC 60684-3-214, IEC 60684-3-246, IEC 60684-3-247, HD631.2
  • UL Rating Yes
  • Other Colors Available No
CAT-M1-ST814A Standard Circular Connectors  1
EN45545 IEC 50155 IEC 61076-2-101 IEC 61373 IP67
  • IP Dust Sealing Level 6
  • IP Water Sealing Level 7
  • Durability Rating 200
  • Packaging Quantity 1
CAT-M1-P489D Standard Circular Connectors  1
EN45545 IEC 50155 IEC 61076-2-101 IEC 61373 IP67
  • IP Dust Sealing Level 6
  • IP Water Sealing Level 7
  • Packaging Quantity 1
CAT-M1-ST814B Standard Circular Connectors  1
EN45545 IEC 50155 IEC 61076-2-101 IEC 61373 IP67
  • IP Dust Sealing Level 6
  • IP Water Sealing Level 7
  • Durability Rating 200
  • Packaging Quantity 1
CAT-SCH691-T1 Power Relays  1
  • Insulation Initial Dielectric Between Contacts & Coil 2500
  • Contact Limiting Continuous Current 20
  • Insulation Creepage Between Contact & Coil 6.36
  • Contact Limiting Making Current 20
  • Insulation Initial Resistance 1000
  • Contact Limiting Short-Time Current 20
  • Insulation Initial Dielectric Between Open Contacts 1500
  • Insulation Creepage Class 5.5 – 8
  • Insulation Initial Dielectric Between Coil & Contact Class 1500 – 2500
  • Insulation Special Features 6000V Initial Surge Withstand Voltage between Contacts & Coil
  • Weight 33
  • Length 32.5
  • Insulation Clearance Class 2.5 – 4
  • Width 27.4
  • Height 27.9
  • Width Class (Mechanical) 25 – 30
  • Insulation Clearance Between Contact & Coil 3.18
  • Height Class (Mechanical) 25 – 30
  • Length Class (Mechanical) 30 – 35
  • Environmental Ambient Temperature Class 70 – 85
  • Environmental Ambient Temperature (Max) 85
CAT-BCIC-RAPC Pre-Formed Insulated Products  1
  • Color Gray
  • Operating Temperature Range 105
  • Application Type Overhead
  • Low Halogen Yes
  • Energized Installation Yes
CAT-BLMT Mechanical Connectors  1
  • Visual Inspection Yes
  • Application Type Power Cable Terminations, Both Underground & Above Ground
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Energized Installation No
CAT-T3437-L779 Standard Labels  1
  • Recommended Printer Ribbon See Printer Ribbon Matrix
  • Printer Technology Laser
  • Recommended Printer See Printer Ribbon Matrix
  • Number of Labels Across 1
CAT-T3437-L769 Safety Symbols & Electrical Signs  1
  • Labels per Sheet 10
  • Printer Technology Non-Printable
  • Number of Labels Across 1
  • Packaging Quantity 10