128958-000 Joints & Splices  1
ANSI C119.1 EN 50393
  • Adhesive Coating Silicone Gel
  • Technology Cold Applied
  • Product Type LV GelWrap
  • Closing Method Snap
  • Cable Seal Gel
  • Filler PowerGel
  • Strain Relief No
  • Component Design PowerGel Sealing Gel
  • Case Seal Gel
  • Number of Main Wires (Max) 1
  • Voltage Class ≤ 1
  • Flexibility Semi-Flexible
  • Color Black
  • Sleeve Length 300
  • Cable Cross-Section (Max) (Main) 500
  • Cable Cross-Section (Min) (Main) 150
  • Cable Diameter (Max) (Main) 50
  • Cable Diameter (Min) (Main) 20
  • Operating Temperature Range -40 – 90
  • Environmental Resistance Yes
  • Chemical Resistance Motor Oil, Hydrochloric Acid, Sodium Chloride, Sodium Hydroxide
  • Silicone-Free No
  • UV-Stabilized Yes
  • Halogen Free Yes
  • Mechanical Resistance Against Mechanical Impact
  • Low Smoke Emission No
  • Emission Free Label-Free Acc (REACH & CLP) Yes
  • Marine-Offshore-Shipbuilding Certified No
  • Solvent-Free Yes
  • Non-Toxic & Non-Corrosive Emission Yes
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Non-Toxic & Non-Corrosive Emission Isocyanate-Free Yes
  • Emission Free Yes
  • Standards ANSI C119.1
  • CSA Certified No
  • UL Rating No
  • Product Availability EMEA
  • Minimum Order Quantity 12
  • Packaging Quantity B12
  • Standard Pack 12
  • Minimum Packaging Unit 1
  • Packaging Method Bag
  • Product Use Outdoor, Overhead & Direct Buried
  • Other Colors Available No
CAT-HVSA-3 Joints & Splices  1
IEEE 404
  • Technology Heat Shrink
  • Insulation Plastic
  • Cable Shield Style Tape
  • Mechanical Connectors Included No
  • Number of Cores 3
  • Voltage Class ≤ 15
  • Armoring AIA
  • Insulation Diameter (Plastic) .65 – 1.05
  • Application Type Inline
  • Design Specification IEEE 404
  • Product Availability AMERICAS
  • Installation Instruction English
CAT-CSJA-1C Joints & Splices  1
IEEE 404
  • Technology Cold Applied
  • Insulation Plastic
  • Cable Shield Style Tape
  • Mechanical Connectors Included No
  • Number of Cores 1
  • Voltage Class ≤ 35
  • Application Type Inline
  • Design Specification IEEE 404
  • Product Availability AMERICAS
  • Installation Instruction English
CAT-CSJA-JCN Joints & Splices  1
IEEE 404
  • Technology Cold Applied
  • Insulation Plastic
  • Cable Shield Style JCN
  • Mechanical Connectors Included Yes
  • Number of Cores 1
  • Voltage Class ≤ 35
  • Application Type Inline
  • Design Specification IEEE 404
  • Product Availability AMERICAS
  • Installation Instruction English
CAT-MXSE Joints & Splices  1
HD CENELEC 629.1 IEC 60502-4
  • Technology Heat Shrink
  • Product Type Medium Voltage Live End Seal
  • Insulation Plastic (XLPE)
  • Cable Shield Style Wire
  • Mechanical Connectors Included Yes
  • Number of Cores 1
  • Voltage Class ≤ 24
  • Outer Insulation Tube
  • Cross-Section Range 240 – 400
  • Insulation Diameter 29.9 – 38.5
  • Conductor Diameter 17.8 – 24.6
  • Sheath Outside Diameter 35 – 49
  • Application Type Live End Seal
  • Standards HD CENELEC 629.1 S2
  • Product Availability EMEA
  • Installation Instruction German
CAT-HVS-C-S-1520S Joints & Splices  1
IEEE 404
  • Technology Heat Shrink
  • Insulation Plastic
  • Cable Shield Style Tape
  • Mechanical Connectors Included No
  • Number of Cores 1
  • Voltage Class ≤ 15
  • Insulation Diameter (Plastic) .65 – .95
  • Application Type Inline
  • Design Specification IEEE 404
  • Product Availability AMERICAS
  • Installation Instruction English
CAT-HVS-T-HVSR-T Joints & Splices  1
IEEE 404
  • Technology Heat Shrink
  • Insulation Plastic
  • Cable Shield Style Tape
  • Mechanical Connectors Included No
  • Number of Cores 3
  • Voltage Class ≤ 25
  • Insulation Diameter (PILC) 1.15 – 1.4
  • Insulation Diameter (Plastic) 1.15 – 1.5
  • Application Type Inline
  • Design Specification IEEE 404
  • Product Availability AMERICAS
CAT-MXSU-REP Joints & Splices  1
HD CENELEC 629.1 IEC 60502-4
  • Technology Heat Shrink
  • Product Type Medium Voltage Repair Joint
  • Insulation Plastic (XLPE)
  • Cable Shield Style Wire
  • Mechanical Connectors Included Yes
  • Number of Cores 1
  • Voltage Class ≤ 24
  • Outer Insulation Tube
  • Cross-Section Range 150 – 300
  • Insulation Diameter 25 – 35.6
  • Conductor Diameter 12.9 – 21.6
  • Sheath Outside Diameter 32 – 46
  • Application Type Inline
  • Standards HD CENELEC 629.1
  • Product Availability AMERICAS
  • Installation Instruction German
CAT-HVS-HVSR-1C Joints & Splices  1
IEEE 404
  • Technology Heat Shrink
  • Insulation Plastic
  • Cable Shield Style Tape
  • Mechanical Connectors Included No
  • Number of Cores 1
  • Voltage Class ≤ 25
  • Insulation Diameter (PILC) 1.2 – 1.7
  • Insulation Diameter (Plastic) 1.3 – 1.75
  • Application Type Inline
  • Design Specification IEEE 404
  • Product Availability AMERICAS
CAT-HVS-1C Joints & Splices  1
IEEE 404
  • Technology Heat Shrink
  • Insulation Plastic
  • Cable Shield Style Tape
  • Mechanical Connectors Included No
  • Number of Cores 1
  • Voltage Class ≤ 8
  • Insulation Diameter (Plastic) .35 – .65
  • Application Type Inline
  • Design Specification IEEE 404
  • Product Availability AMERICAS
  • Installation Instruction English
CAT-MXSU-INL-3C Joints & Splices  1
HD CENELEC 629.1 IEC 60502-4
  • Technology Heat Shrink
  • Product Type Medium Voltage Inline Joint
  • Insulation Plastic (XLPE)
  • Cable Shield Style Wire
  • Mechanical Connectors Included Yes
  • Number of Cores 3
  • Voltage Class ≤ 24
  • Outer Insulation Tube
  • Cross-Section Range 25 – 95
  • Insulation Diameter 17.9 – 26
  • Conductor Diameter 5.2 – 12
  • Sheath Outside Diameter 48 – 72
  • Application Type Inline
  • Standards HD CENELEC 629.1
  • Product Availability EMEA
  • Installation Instruction German
CAT-MXSU-INL-1C Joints & Splices  2
HD CENELEC 629.1
  • Technology Heat Shrink
  • Insulation Plastic
  • Cable Shield Style Wire
  • Mechanical Connectors Included Yes
  • Number of Cores 1
  • Voltage Class ≤ 12
  • Cross-Section Range 240 – 400
  • Insulation Diameter 25.7 – 32.6
  • Conductor Diameter 17.8 – 24.6
  • Sheath Outside Diameter 33 – 47
  • Application Type Inline
  • Design Specification HD CENELEC 629.1
  • Product Availability EMEA
  • Installation Instruction German
CAT-HVS-C-SJ Joints & Splices  1
IEEE 404
  • Technology Heat Shrink
  • Insulation Plastic
  • Cable Shield Style JCN
  • Mechanical Connectors Included No
  • Number of Cores 1
  • Voltage Class ≤ 15
  • Insulation Diameter (Plastic) .85 – 1.3
  • Application Type Inline
  • Design Specification IEEE 404
  • Product Availability AMERICAS
  • Installation Instruction English
CAT-BV Joints & Splices  1
EN 50393
  • Technology Resin
  • Product Type LV Resin Straight Joint
  • Closing Method Snap
  • Cable Seal Foam
  • Filler PU RAPID 4300B
  • Strain Relief No
  • Filler Packing (D/C) Double Chamber Bags
  • Connector Type Connector Block
  • Case Seal Labyrinth
  • Number of Main Wires (Max) 5
  • Voltage Class ≤ 1
  • Color Transparent
  • Partition Orientation Horizontal
  • Cable Cross-Section (Max) (Main) 6
  • Cable Cross-Section (Min) (Main) 1.5
  • Cable Diameter (Max) (Main) 20
  • Cable Diameter (Min) (Main) 13
  • Filler Volume .35
  • Operating Temperature Range -20 – 55
  • Chemical Resistance Water, Humic Acids
  • Silicone-Free Yes
  • UV-Stabilized No
  • Halogen Free Yes
  • Low Smoke Emission No
  • Marine-Offshore-Shipbuilding Certified No
  • Solvent-Free Yes
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Non-Toxic & Non-Corrosive Emission Isocyanate-Free No
  • Standards EN 50393
  • CSA Certified No
  • UL Rating No
  • Product Availability AMERICAS
  • Minimum Order Quantity 1
  • Packaging Quantity 1
  • Minimum Packaging Unit 1
  • Packaging Method Cardbox
  • Product Use Outdoor & Direct Buried
  • Other Colors Available No
CAT-HVS-Y Joints & Splices  1
IEEE 404
  • Technology Heat Shrink
  • Insulation Plastic
  • Cable Shield Style Tape
  • Mechanical Connectors Included No
  • Number of Cores 1
  • Voltage Class ≤ 15
  • Insulation Diameter (Main, Y-Only) .95 – 1.45
  • Insulation Diameter (Tap, Y-Only) .85 – 1.45
  • Application Type Branch
  • Design Specification IEEE 404
  • Product Availability AMERICAS
  • Installation Instruction English
CAT-MXSB Joints & Splices  1
HD CENELEC 629.1 IEC 60502-4
  • Technology Heat Shrink
  • Product Type Medium Voltage Branch Joint
  • Insulation Plastic (XLPE)
  • Cable Shield Style Wire
  • Mechanical Connectors Included Yes
  • Number of Cores 1
  • Voltage Class ≤ 24
  • Outer Insulation Tube
  • Cross-Section Range 70 – 185
  • Insulation Diameter 21.9 – 30.1
  • Conductor Diameter 8.7 – 16.8
  • Sheath Outside Diameter 30 – 39
  • Application Type Branch
  • Standards HD CENELEC 629.1 S2
  • Product Availability EMEA
  • Installation Instruction German
CAT-RVS Joints & Splices  1
ANSI C119.1
  • Technology Cold Applied
  • Product Type Roll-On Sleeves
  • Closing Method Roll-On
  • Cable Seal Mastic
  • Strain Relief No
  • Number of Main Wires (Max) 1
  • Voltage Class ≤ 1
  • Color Black
  • Cable Cross-Section (Max) (Main) 70
  • Cable Cross-Section (Min) (Main) 10
  • Cable Diameter (Max) (Main) 17
  • Cable Diameter (Min) (Main) 9
  • Operating Temperature Range -40 – 130
  • Chemical Resistance Water, Humic Acids
  • Silicone-Free No
  • UV-Stabilized Yes
  • Halogen Free Yes
  • Low Smoke Emission No
  • Emission Free Label-Free Acc (REACH & CLP) Yes
  • Marine-Offshore-Shipbuilding Certified No
  • Solvent-Free Yes
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Non-Toxic & Non-Corrosive Emission Isocyanate-Free Yes
  • Standards ANSI C119.1
  • CSA Certified Yes
  • UL Rating Yes
  • Product Availability AMERICAS
  • Minimum Order Quantity 1
  • Packaging Quantity 1
  • Minimum Packaging Unit 1
  • Packaging Method Bag
  • Product Use Outdoor, Overhead & Direct Buried
  • Other Colors Available No
CAT-MXSU-TRANS Joints & Splices  1
HD CENELEC 629.2
  • Technology Heat Shrink
  • Product Type Medium Voltage Transition Joint
  • Insulation Paper (PILC)
  • Cable Shield Style Wire Copper
  • Mechanical Connectors Included Yes
  • Number of Cores 1
  • Voltage Class ≤ 24
  • Outer Insulation Tube
  • Armoring Wire Steel
  • Cross-Section Range 25 – 70
  • Insulation Diameter 17 – 21.9
  • Conductor Diameter 5.6 – 12
  • Sheath Outside Diameter 24 – 38
  • Application Type Transition
  • Standards HD CENELEC 629.2
  • Product Availability EMEA
  • Installation Instruction German
CAT-BAV-2 Joints & Splices  1
EN 50393
  • Technology Resin
  • Product Type LV Resin Branch Joint
  • Closing Method Snap
  • Cable Seal Foam
  • Filler PU RAPID 4300B
  • Strain Relief No
  • Filler Packing (D/C) Double Chamber Bags
  • Tap Geometry Y
  • Connector Type Connector Wedge
  • Case Seal Labyrinth
  • Number of Main Wires (Max) 4
  • Number of Branch Wires (Max) 4
  • Voltage Class ≤ 1
  • Color Transparent
  • Partition Orientation Horizontal
  • Cable Cross-Section (Max) (Main) 25
  • Cable Cross-Section (Min) (Main) 10
  • Cable Diameter (Max) (Main) 30
  • Branch Cable Cross-Section (Min) 6
  • Branch Cable Diameter (Max) 30
  • Branch Cable Cross-Section (Max) 25
  • Filler Volume .8
  • Operating Temperature Range -20 – 55
  • Chemical Resistance Water, Humic Acids
  • Silicone-Free Yes
  • UV-Stabilized No
  • Halogen Free Yes
  • Low Smoke Emission No
  • Marine-Offshore-Shipbuilding Certified No
  • Solvent-Free Yes
  • Free of Lead, Cadmium, Heavy Metals Yes
  • Non-Toxic & Non-Corrosive Emission Isocyanate-Free No
  • Standards EN 50393
  • CSA Certified No
  • UL Rating No
  • Product Availability AMERICAS
  • Minimum Order Quantity 1
  • Packaging Quantity 1
  • Minimum Packaging Unit 1
  • Packaging Method Cardbox
  • Product Use Outdoor & Direct Buried
  • Other Colors Available No
CAT-CSJT Joints & Splices  1
IEC 60502-4
  • Mechanical Lug Included (Shield) No
  • Termination Length 391 – 460
  • Technology Cold Applied
  • Cable Shield Style Tape
  • Compression Lug Included (Conductor) No
  • Coating Style Painting
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) No
  • Mechanical Lug Included (Conductor) No
  • Number of Cores 1
  • Voltage Class ≤ 17.5
  • Armoring Steel Tape
  • Length (Installed) 900
  • Cross-Section Range 50 – 150
  • Insulation Diameter 18 – 26
  • Operating Temperature Range -40 – 40
  • Design Specification IEC 60502-4
  • Product Availability China
  • Installation Instruction Chinese