202D163-4-0 Heat Shrink Boots
MODUK DEF STAN 59-97
  • Molded Part Shape Straight
  • Lipped Yes
  • Material Code 4
  • Material Systems Code 10
  • Adhesive Pre-Coat No
  • Material Polyolefin Flexible Modified
  • Cable Diameter Range 9.9 – 22.1
  • Wire/Cable Outside Diameter .43 in
  • Operating Temperature Range -55 – 135
  • Power Cable Accessory No
  • Approved Standards SAE AS I 81765/1, Type II
  • Government Qualified No
  • Molded Part Shape Code 202
  • Fluid/Chemical Resistance Occasional exposure to fluids
  • Adhesive Options /42 Precoat
  • Adhesive Type Adhesive Purchased Separately
S02-07-R-3 SolderSleeve Shield Terminators
  • Product Type Shield Terminator
  • Temperature Indicator Yes
  • Splice Type Shield Terminator
  • Temperature Indicator Type Thermochromic
  • Pre-Installed Lead Yes
  • Pre-Installed Lead Type 55A0111
  • Lead Stranding Stranded
  • Lead Plating Material Tin
  • Lead Color Orange
  • Termination Method Solder
  • Jacket Outside Diameter 2.65
  • Expanded Inside Diameter (Min) 2.65
  • Recovered Inside Diameter (Max) 1.4
  • Dielectric Outside Diameter (Max) .75
  • Overall Length 16.5
  • Shield Outside Diameter (Min) 1.4
  • Pre-Installed Lead Wire Size .38
  • Pre-Installed Lead Wire Size 22
  • Pre-Installed Lead Wire Size 754
  • Resistance Properties Immersion Protection
  • Wire Temperature (Max) 105
  • MIL/NAS Specification (MIL-S-83519, NAS-1747) AS83519/2
  • Government Qualified Yes
S1048-TAPE-1X100-FT Hot Melt Tape  1
  • Product Type Adhesive
  • Tape Width 25.4
  • Roll Length 30.5
  • Operating Temperature Range -55 – 120
  • Installation Temperature 160
  • Class S1048
  • Pre-Coat Designation /86
  • Specification RK6626
  • Packaging Method Roll
  • Comment Highest service temperature Hot-melt.
381A301-125-0 Breakouts/Transitions
  • Size Code 01
  • Number of Branches/Legs 3
  • Material Code 125
  • Material Systems Code 300
  • Adhesive Pre-Coat No
  • Material Modified Fluoropolymer
  • Inside Diameter Range (Body) 6.6 – 19.8
  • Inside Diameter Range (Leg 1) 6.6 – 13.2
  • Inside Diameter Range (Leg 2) 6.6 – 13.2
  • Resistant To Abrasion
  • Operating Temperature Range -55 – 175
  • Flammability Flame-Retardant
  • Power Cable Accessory No
  • Government Qualified No
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Options None
  • Comment Contact Raychem for additional adhesive and/or cut off boot length information
  • Adhesive Code S1255-04
462A023-3-0 Breakouts/Transitions
MODUK DEF STAN 59-97
  • Molded Part Shape Y Shape
  • Size Code 023
  • Number of Branches/Legs 4
  • Material Code 3
  • Material Systems Code 10
  • Adhesive Pre-Coat No
  • Material Semi-Rigid Modified Polyolefin
  • Inside Diameter Range (Body) 13.2 – 26.9
  • Inside Diameter Range (Leg 1) 6.9 – 13.2
  • Inside Diameter Range (Leg 3) 6.9 – 13.2
  • Inside Diameter Range (Leg 2) 6.9 – 13.2
  • Operating Temperature Range -55 – 135
  • Power Cable Accessory No
  • Government Qualified No
  • Molded Part Shape Code 462A
  • Fluid/Chemical Resistance Occasional exposure to fluids
  • Adhesive Type Adhesive Purchased Separately
  • Adhesive Code S1125
S1124-TAPE-0.75X100-FT Hot Melt Tape  1
  • Product Type Thermoplastic Adhesive
  • Tape Width 19
  • Roll Length 30.5
  • Operating Temperature Range -55 – 105
  • Installation Temperature 150
  • Class S1124
  • Pre-Coat Designation /164
  • Specification RT-1050/13
  • Packaging Method Roll
  • Comment Requires reflowing in an oven at 150°C for 30 minutes.
CV7361-000 Heat Shrink Boots
  • Molded Part Shape Straight
  • Lipped Yes
  • Material Code 25
  • Material Systems Code 25
  • Adhesive Pre-Coat No
  • Material Fluid Resistant Modified Elastomer
  • Cable Diameter Range 5.9 – 14
  • Connector or Backshell Outside Diameter .63 in
  • Wire/Cable Outside Diameter .276 in
  • Operating Temperature Range -75 – 150
  • Power Cable Accessory No
  • Molded Part Shape Code 202
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Options /225 Precoat
  • Adhesive Type Adhesive Purchased Separately
806702-000 Heat Shrink Boots
DIN VG 95343-6 DIN VG 95343-7 DIN VG 95343-8 Beiblatt 1 DIN VG 95343-9 MODUK DEF STAN 59-97
  • Molded Part Shape 90°
  • Lipped No
  • Material Code 25
  • Material Systems Code 25
  • Adhesive Pre-Coat No
  • Material Fluid Resistant Modified Elastomer
  • Cable Diameter Range 6.9 – 22.9
  • Wire/Cable Outside Diameter .3 in
  • Operating Temperature Range -75 – 150
  • Power Cable Accessory No
  • Approved Standards BS-G-198-5-DE
  • Government Qualified No
  • Molded Part Shape Code 222
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Options /225 Precoat
  • Adhesive Type Adhesive Purchased Separately
S1017-1.0X50 Hot Melt Tape  1
  • Product Type Adhesive
  • Operating Temperature Range -20 – 60
202K174-3-0 Heat Shrink Boots
MODUK DEF STAN 59-97
  • Molded Part Shape Straight
  • Lipped Yes
  • Material Code 3
  • Material Systems Code 10
  • Adhesive Pre-Coat No
  • Material Semi-Rigid Modified Polyolefin
  • Cable Diameter Range 15.7 – 35
  • Wire/Cable Outside Diameter .7 in
  • Operating Temperature Range -55 – 135
  • Power Cable Accessory No
  • Approved Standards BS-G-198-5-DA
  • Government Qualified No
  • Molded Part Shape Code 202
  • Fluid/Chemical Resistance Occasional exposure to fluids
  • Adhesive Options /42 Precoat
  • Adhesive Type Adhesive Purchased Separately
195133-000 Epoxy  1
  • Product Type Adhesive Tape
  • System 300
  • Color (Cured) Black
  • Color (Supplied) Black
  • Heat Resistance Temperature (Max) 200
  • Packaging Method Roll
  • Packaging Quantity 1
  • Comment 1-Part Epoxy Tape
  • Curing Method 150 °C for 50 min
207W234-3-01-0 Feedthroughs
  • Product Type Cable Entry Seals/Feedthroughs
  • Size Code 34
  • Included O-Ring No
  • Material Code 3
  • Nut Type B
  • Color Black
  • Material Modified Polyolefin
  • Pliancy Semi-Rigid
  • Adhesive Pre-Coat No
  • Mounting Hole Diameter 47
  • Threaded End Inside Diameter 30.1
  • Expanded Inside Diameter (Min) 27.9
  • Recovered Inside Diameter (Max) 12
  • Recovered Wall Thickness (Nominal) 2.03
  • Length 87
  • Resistant To Abrasion, Fluids, Mechanical Damage, Strain
  • Resistance Properties Immersion Protection
  • Power Cable Accessory No
  • Government Qualified No
  • Adhesive Type Adhesive Purchased Separately
  • Adhesive Code S1017
S1030-TAPE-3/4X33FT Hot Melt Tape  1
  • Product Type Polyolefin Adhesive
  • Tape Width 19
  • Roll Length 10
  • Operating Temperature Range -80 – 80
  • Installation Temperature 120
  • Class S1030
  • Pre-Coat Designation /180
  • Specification RK6017
  • Packaging Method Roll
  • Comment Good low temperature flexibility.
CES-1R Cable Entry Seals
  • Angle 90°
  • Product Type Heat Shrink Cable Entry Seal
  • Number of Branches/Legs 1
  • Seal Type Standard
  • Material Nylon
  • Screw & Hole Thread Size 1-12
  • Expanded Inside Diameter (Min) 14
  • Recovered Inside Diameter (Max) 7.1
  • Drill Size 1
  • Cable Diameter Range 7.36 – 10.92
  • Overall Length (Supplied) 35.56
  • Overall Length (Recovered) 35.56
  • Flammability Flame-Retardant
  • Comment Molded part has hot-melt adhesive preinstalled.
D14-30FR Breakouts/Transitions
  • Size Code 14-30
  • Number of Branches/Legs 2
  • Material Code 3
  • Adhesive Pre-Coat Yes
  • Material Modified Polyolefin
  • Inside Diameter Range (Body) 15.24 – 30.48
  • Inside Diameter Range (Leg 1) 4.3 – 12.7
  • Inside Diameter Range (Leg 2) 4.3 – 12.7
  • Operating Temperature Range -55 – 90
  • Power Cable Accessory No
  • Government Qualified No
  • Adhesive Options /97 Precoat
  • Adhesive Code 97
562A011-4/42-0 Breakouts/Transitions
MODUK DEF STAN 59-97
  • Molded Part Shape Y Shape
  • Size Code 011
  • Number of Branches/Legs 5
  • Material Code 4
  • Material Systems Code 10
  • Adhesive Pre-Coat Yes
  • Material Polyolefin Flexible Modified
  • Inside Diameter Range (Body) 6.9 – 13.2
  • Inside Diameter Range (Leg 1) 3.5 – 6.6
  • Inside Diameter Range (Leg 3) 3.5 – 6.6
  • Inside Diameter Range (Leg 4) 3.5 – 6.6
  • Inside Diameter Range (Leg 2) 3.5 – 6.6
  • Operating Temperature Range -55 – 135
  • Power Cable Accessory No
  • Government Qualified No
  • Molded Part Shape Code 562A
  • Fluid/Chemical Resistance Occasional exposure to fluids
  • Adhesive Options /42 Precoat
  • Adhesive Type High Performance Pre-Coat Adhesive
  • Adhesive Code 42
202A142-25/86-0 Heat Shrink Boots
  • Molded Part Shape Straight
  • Lipped No
  • Material Code 25
  • Material Systems Code 25
  • Adhesive Pre-Coat Yes
  • Material Fluid Resistant Modified Elastomer
  • Cable Diameter Range 7.4 – 25.4
  • Wire/Cable Outside Diameter .3 in
  • Operating Temperature Range -75 – 150
  • Power Cable Accessory No
  • Approved Standards BS-G-198-5-DE
  • Government Qualified No
  • Molded Part Shape Code 202
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Type High Performance Pre-Coat Adhesive
462A034-25-0 Breakouts/Transitions
DIN VG 95343-6 DIN VG 95343-7 DIN VG 95343-8 Beiblatt 1 DIN VG 95343-9 MODUK DEF STAN 59-97
  • Molded Part Shape Y Shape
  • Size Code 034
  • Number of Branches/Legs 4
  • Material Code 25
  • Material Systems Code 25
  • Adhesive Pre-Coat No
  • Material Fluid Resistant Modified Elastomer
  • Inside Diameter Range (Body) 18.8 – 38.6
  • Inside Diameter Range (Leg 1) 9.7 – 19.3
  • Inside Diameter Range (Leg 3) 9.7 – 19.3
  • Inside Diameter Range (Leg 2) 9.7 – 19.3
  • Operating Temperature Range -75 – 150
  • Power Cable Accessory No
  • Government Qualified No
  • Molded Part Shape Code 462A
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Type Adhesive Purchased Separately
  • Comment Contact Raychem for additional adhesive and/or cut off boot length information
  • Adhesive Code S1125
202A163-25-0 Heat Shrink Boots
  • Molded Part Shape Straight
  • Lipped No
  • Material Code 25
  • Material Systems Code 25
  • Adhesive Pre-Coat No
  • Material Fluid Resistant Modified Elastomer
  • Cable Diameter Range 9.4 – 27.2
  • Wire/Cable Outside Diameter .43 in
  • Operating Temperature Range -75 – 150
  • Power Cable Accessory No
  • Approved Standards BS-G-198-5-DE
  • Government Qualified No
  • Molded Part Shape Code 202
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Options /225 Precoat
  • Adhesive Type Adhesive Purchased Separately
214A011-3-0 D-Sub Connector Boots
  • Molded Part Type D Subminiature Boot
  • Angle Straight
  • Sealable No
  • Product Type Molded Boot
  • Material Code 3
  • Adhesive Pre-Coating Without
  • Material Systems Code 10
  • Material Semi rigid Modified Polyolefin
  • Connector Width 10.7
  • Adhesive Options S1006 Separate Adhesive
  • Adhesive Code S1125