CAT-R21-D976 Heat Shrink Tubing  1
PRODUCT
  1. Heat Shrink Tubing
  2. Heat Shrink Tubing
  1. Dual Wall DWP-125 Spool HS Tubing CAT-R21-D976
active
  • Wall Type Dual
  • Product Family DWP-125
  • Voltage (Max) .6
  • Primary Product Color Black
  • Shrink Ratio 3:1
  • Primary Product Material Crosslinked Polyolefin
  • Flexibility Flexible
  • Fluid Type Brake Fluid
  • Expanded Inside Diameter (Min) 3.18
  • Recovered Inside Diameter (Max) 1
  • Heat Shrink Tubing Size Range 1 – 3.2
  • Cut Length 152.4
  • Shrink Temperature (Min) 80
  • Heat Shrink Tubing Flammability Flame-Retardant
  • Operating Temperature Range -40 – 110
  • Heat Shrink Tubing Resistance Fluids
  • Recovery Temperature 125
  • Fluid Resistance Splash Protection
  • Applicable Region Americas
  • Packaging Method Box
  • Meets Low Outgassing Requirements No
  • Product Source US
CAT-R21-B3228 Heat Shrink Tubing  1
PRODUCT
  1. Heat Shrink Tubing
  2. Heat Shrink Tubing
  1. Single Wall RNF-100 Reel HS Tubing CAT-R21-B3228
active
  • Wall Type Dual
  • Voltage (Max) .6
  • Primary Product Color Black
  • Shrink Ratio 2:1
  • Primary Product Material Irradiated Modified Polyolefin
  • Flexibility Semi-Rigid
  • Fluid Type Brake Fluid
  • Expanded Inside Diameter (Min) 12.7
  • Recovered Inside Diameter (Max) 6.1
  • Recovered Wall Thickness (Tolerance) .28
  • Cut Length 1220
  • Shrink Temperature (Min) 110
  • Heat Shrink Tubing Flammability Flame-Retardant
  • Operating Temperature Range -40 – 130
  • Heat Shrink Tubing Resistance Abrasion
  • Recovery Temperature 135
  • Fluid Resistance Limited Immersion Protection
  • Applicable Region Global
  • Packaging Method Piece
  • Meets Low Outgassing Requirements No
  • Product Source China
RT-780-3/4-0-SP Heat Shrink Tubing  1
  • Wall Type Single
  • Primary Product Color Black
  • Shrink Ratio 2:1
  • Primary Product Material Crosslinked Fluoroelastomer
  • Flexibility Semi-Rigid
  • Fluid Type Aviation Fuel
  • Material Systems Code 780 NBC
  • Expanded Inside Diameter (Min) 19.05
  • Recovered Inside Diameter (Max) 9.5
  • Heat Shrink Tubing Size Range 9.5 – 19.05
  • Recovered Wall Thickness (Nominal) .81
  • Shrink Temperature (Min) 175
  • Heat Shrink Tubing Flammability Flame-Retardant
  • Operating Temperature Range -55 – 175
  • Heat Shrink Tubing Resistance Fluids
  • Recovery Temperature 200
  • Fluid Resistance Immersion Protection
  • Applicable Region Worldwide
  • Packaging Method Piece
  • Meets Low Outgassing Requirements No
  • Product Source US
382A023-3/86-0 Breakouts & Transitions
MODUK DEF STAN 59-97
  • Molded Part Shape Y Shape
  • Size Code 023
  • Number of Branches/Legs 3
  • Material Code 3
  • Breakout & Transition Material Systems Code 10
  • Adhesive Pre-Coat Yes
  • Material Semi-Rigid Modified Polyolefin
  • Inside Diameter Range (Body) 12.4 – 26.9
  • Inside Diameter Range (Leg 1) 6.1 – 13.2
  • Inside Diameter Range (Leg 2) 6.1 – 13.2
  • Operating Temperature Range -55 – 135
  • Power Cable Accessory No
  • Government Qualified No
  • Molded Part Shape Code 382A
  • Fluid/Chemical Resistance Occasional exposure to fluids
  • Adhesive Options /86 Precoat
  • Breakout & Transition Adhesive Type High Performance Pre-Coat Adhesive
  • Adhesive Code 86
202S174-25C-0 EMI Shielded Boots  1
PRODUCT
  1. Harnessing
  2. EMI Shielded Boots
  1. 202S174-25C-0 202S174-25C-0
active
  • Molded Part Type EMI Shielded Molded Parts
  • Angle Straight
  • Product Type Molded Part
  • Material Code 25
  • EMI Shielded Boot Color Black
  • EMI Shielded Boot Material Systems Code 25
  • EMI Shielded Boot Material Modified Elastomer
  • Adhesive Pre-Coat No
  • Operating Temperature Range -75 – 150
  • EMI Shielded Boot Adhesive Type Adhesive Purchased Separately
CV7371-000 Heat Shrink Boots
PRODUCT
  1. Harnessing
  2. Heat Shrink Boots
  1. 222K174-25L-0 CV7371-000
active
  • Molded Part Shape 90°
  • Lipped Yes
  • Material Code 25
  • Heat Shrink Boot Material Systems Code 25
  • Adhesive Pre-Coat No
  • Material Fluid Resistant Modified Elastomer
  • Cable Diameter Range 15.7 – 35
  • Connector or Backshell Outside Diameter 1.5 in
  • Wire/Cable Outside Diameter .7 in
  • Operating Temperature Range -75 – 150
  • Power Cable Accessory No
  • Molded Part Shape Code 222
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Options /225 Precoat
  • Adhesive Type Adhesive Purchased Separately
F42-60-FR Breakouts & Transitions
  • Number of Branches/Legs 4
  • Material Code 3
  • Breakout & Transition Material Systems Code 10
  • Adhesive Pre-Coat No
  • Material Modified Polyolefin
  • Operating Temperature Range -55 – 200
  • Power Cable Accessory No
  • Government Qualified No
  • Breakout & Transition Adhesive Type Adhesive Purchased Separately
  • Comment Heavy Duty
462A046-25-0 Breakouts & Transitions
DIN VG 95343-6 DIN VG 95343-7 DIN VG 95343-8 Beiblatt 1 DIN VG 95343-9 MODUK DEF STAN 59-97
  • Molded Part Shape Y Shape
  • Size Code 046
  • Number of Branches/Legs 4
  • Material Code 25
  • Breakout & Transition Material Systems Code 25
  • Adhesive Pre-Coat No
  • Material Fluid Resistant Modified Elastomer
  • Inside Diameter Range (Body) 25.4 – 55.6
  • Inside Diameter Range (Leg 1) 12.4 – 26.9
  • Inside Diameter Range (Leg 3) 12.4 – 26.9
  • Inside Diameter Range (Leg 2) 12.4 – 26.9
  • Operating Temperature Range -75 – 150
  • Power Cable Accessory No
  • Government Qualified No
  • Molded Part Shape Code 462A
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Breakout & Transition Adhesive Type Adhesive Purchased Separately
  • Comment Contact Raychem for additional adhesive and/or cut off boot length information
  • Adhesive Code S1125
562A011-4/42-0 Breakouts & Transitions
MODUK DEF STAN 59-97
  • Molded Part Shape Y Shape
  • Size Code 011
  • Number of Branches/Legs 5
  • Material Code 4
  • Breakout & Transition Material Systems Code 10
  • Adhesive Pre-Coat Yes
  • Material Polyolefin Flexible Modified
  • Inside Diameter Range (Body) 6.9 – 13.2
  • Inside Diameter Range (Leg 1) 3.5 – 6.6
  • Inside Diameter Range (Leg 3) 3.5 – 6.6
  • Inside Diameter Range (Leg 4) 3.5 – 6.6
  • Inside Diameter Range (Leg 2) 3.5 – 6.6
  • Operating Temperature Range -55 – 135
  • Power Cable Accessory No
  • Government Qualified No
  • Molded Part Shape Code 562A
  • Fluid/Chemical Resistance Occasional exposure to fluids
  • Adhesive Options /42 Precoat
  • Breakout & Transition Adhesive Type High Performance Pre-Coat Adhesive
  • Adhesive Code 42
CV7370-000 Heat Shrink Boots
PRODUCT
  1. Harnessing
  2. Heat Shrink Boots
  1. 222K163-25L-0 CV7370-000
active
  • Molded Part Shape 90°
  • Lipped Yes
  • Material Code 25
  • Heat Shrink Boot Material Systems Code 25
  • Adhesive Pre-Coat No
  • Material Fluid Resistant Modified Elastomer
  • Cable Diameter Range 9.9 – 22
  • Connector or Backshell Outside Diameter 1.26 in
  • Wire/Cable Outside Diameter .43 in
  • Operating Temperature Range -75 – 150
  • Power Cable Accessory No
  • Molded Part Shape Code 222
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Options /225 Precoat
  • Adhesive Type Adhesive Purchased Separately
RT-770-1/2-0-SP Heat Shrink Tubing
  • Wall Type Single
  • Primary Product Color Black
  • Shrink Ratio 2:1
  • Primary Product Material Crosslinked Fluoroelastomer
  • Flexibility Flexible
  • Fluid Type Aviation Fuel
  • Material Systems Code 770 NBC
  • Expanded Inside Diameter (Min) 12.7
  • Recovered Inside Diameter (Max) 6.4
  • Heat Shrink Tubing Size Range 6.4 – 12.7
  • Recovered Wall Thickness (Nominal) .08
  • Shrink Temperature (Min) 150
  • Heat Shrink Tubing Flammability Highly Flame-Retardant
  • Operating Temperature Range -55 – 125
  • Heat Shrink Tubing Resistance Fluids
  • Recovery Temperature 150
  • Fluid Resistance Immersion Protection
  • Applicable Region Worldwide
  • Packaging Method Piece
  • Meets Low Outgassing Requirements No
  • Product Source US
SSB-2002FR Breakouts & Transitions
  • Size Code 2002
  • Number of Branches/Legs 2
  • Material Code 3
  • Adhesive Pre-Coat Yes
  • Material Modified Polyolefin
  • Inside Diameter Range (Body) 35.56 – 50.8
  • Inside Diameter Range (Leg 1) 8.89 – 19.05
  • Inside Diameter Range (Leg 2) 8.89 – 19.05
  • Operating Temperature Range -55 – 90
  • Power Cable Accessory No
  • Government Qualified No
  • Adhesive Options /97 Precoat
  • Adhesive Code 97
RHW-70/20-1200/ADH-0 Heat Shrink Tubing
PRODUCT
  1. Heat Shrink Tubing
  2. Heat Shrink Tubing
  1. RHW-70/20-1200/ADH-0 RHW-70/20-1200/ADH-0
active
  • Wall Type Dual
  • Product Family RHW
  • Voltage (Max) .6
  • Primary Product Color Black
  • Shrink Ratio 3.5:1
  • Primary Product Material Irradiated Modified Polyolefin
  • Flexibility Semi-Rigid
  • Fluid Type VDE 0370 Oil
  • Expanded Inside Diameter (Min) 70
  • Recovered Inside Diameter (Max) 20
  • Recovered Wall Thickness (Tolerance) 4.39
  • Cut Length 1200
  • Shrink Temperature (Min) 110
  • Heat Shrink Tubing Flammability Non-Flame-Retardant
  • Operating Temperature Range -40 – 110
  • Heat Shrink Tubing Resistance Abrasion
  • Recovery Temperature 125
  • Fluid Resistance Moisture/Spray Protection
  • Applicable Region Global
  • Packaging Method Piece
  • Meets Low Outgassing Requirements No
  • Product Source Germany
202F221-770-0 Heat Shrink Boots  1
  • Molded Part Shape Straight
  • Lipped Yes
  • Material Code 770
  • Heat Shrink Boot Material Systems Code 770
  • Adhesive Pre-Coat No
  • Material NBCCS
  • Connector or Backshell Outside Diameter .63 in
  • Wire/Cable Outside Diameter .28 in
  • Operating Temperature Range -55 – 125
  • Molded Part Shape Code 202
  • Fluid/Chemical Resistance Chemical, Biological, Radiological and Nuclear (CBRN)
  • Adhesive Options S1264 Separate Adhesive
202D242-25/225-0 Heat Shrink Boots
PRODUCT
  1. Harnessing
  2. Heat Shrink Boots
  1. 202D242-25/225-0 202D242-25/225-0
active
DIN VG 95343-6 DIN VG 95343-7 DIN VG 95343-8 Beiblatt 1 DIN VG 95343-9 MODUK DEF STAN 59-97
  • Molded Part Shape Straight
  • Lipped Yes
  • Material Code 25
  • Heat Shrink Boot Material Systems Code 25
  • Adhesive Pre-Coat Yes
  • Material Fluid Resistant Modified Elastomer
  • Cable Diameter Range 9.7 – 21.3
  • Wire/Cable Outside Diameter .43 in
  • Operating Temperature Range -75 – 150
  • Power Cable Accessory No
  • Approved Standards BS-G-198-5-DE
  • Government Qualified No
  • Molded Part Shape Code 202
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
202K174-25L-0 Heat Shrink Boots
PRODUCT
  1. Harnessing
  2. Heat Shrink Boots
  1. 202K174-25L-0 202K174-25L-0
active
  • Molded Part Shape Straight
  • Lipped Yes
  • Material Code 25
  • Heat Shrink Boot Material Systems Code 25
  • Adhesive Pre-Coat No
  • Material Fluid Resistant Modified Elastomer
  • Cable Diameter Range 15.7 – 35
  • Connector or Backshell Outside Diameter 1.5 in
  • Wire/Cable Outside Diameter .7 in
  • Operating Temperature Range -75 – 150
  • Power Cable Accessory No
  • Molded Part Shape Code 202
  • Fluid/Chemical Resistance Long-Term Exposure at High Temperature
  • Adhesive Options /225 Precoat
  • Adhesive Type Adhesive Purchased Separately
RMW-85/25-1200/ADH-0 Heat Shrink Tubing
PRODUCT
  1. Heat Shrink Tubing
  2. Heat Shrink Tubing
  1. RMW-85/25-1200/ADH-0 RMW-85/25-1200/ADH-0
active
  • Wall Type Dual
  • Product Family RMW
  • Voltage (Max) .6
  • Primary Product Color Black
  • Shrink Ratio 3:1
  • Primary Product Material Irradiated Modified Polyolefin
  • Flexibility Semi-Rigid
  • Fluid Type VDE 0370 Oil
  • Expanded Inside Diameter (Min) 85
  • Recovered Inside Diameter (Max) 25
  • Heat Shrink Tubing Size Range 25 – 85
  • Recovered Wall Thickness (Tolerance) 2.79
  • Cut Length 1200
  • Shrink Temperature (Min) 110
  • Heat Shrink Tubing Flammability Non-Flame-Retardant
  • Operating Temperature Range -40 – 110
  • Heat Shrink Tubing Resistance Abrasion
  • Recovery Temperature 125
  • Fluid Resistance Moisture/Spray Protection
  • Applicable Region Global
  • Packaging Method Box
  • Meets Low Outgassing Requirements No
  • Product Source Germany
222D211-3-0 Heat Shrink Boots
MODUK DEF STAN 59-97
  • Molded Part Shape 90°
  • Lipped Yes
  • Material Code 3
  • Heat Shrink Boot Material Systems Code 10
  • Adhesive Pre-Coat No
  • Material Semi-Rigid Modified Polyolefin
  • Cable Diameter Range 6.4 – 14
  • Wire/Cable Outside Diameter .276 in
  • Operating Temperature Range -55 – 135
  • Power Cable Accessory No
  • Approved Standards BS-G-198-5-DA
  • Government Qualified No
  • Molded Part Shape Code 222
  • Fluid/Chemical Resistance Occasional exposure to fluids
  • Adhesive Options /42 Precoat
  • Adhesive Type Adhesive Purchased Separately
462A023-4/42-0 Breakouts & Transitions
MODUK DEF STAN 59-97
  • Molded Part Shape Y Shape
  • Size Code 023
  • Number of Branches/Legs 4
  • Material Code 4
  • Breakout & Transition Material Systems Code 10
  • Adhesive Pre-Coat Yes
  • Material Polyolefin Flexible Modified
  • Inside Diameter Range (Body) 13.2 – 26.9
  • Inside Diameter Range (Leg 1) 6.9 – 13.2
  • Inside Diameter Range (Leg 3) 6.9 – 13.2
  • Inside Diameter Range (Leg 2) 6.9 – 13.2
  • Operating Temperature Range -55 – 135
  • Power Cable Accessory No
  • Government Qualified No
  • Molded Part Shape Code 462A
  • Fluid/Chemical Resistance Occasional exposure to fluids
  • Adhesive Options /42 Precoat
  • Breakout & Transition Adhesive Type High Performance Pre-Coat Adhesive
  • Adhesive Code 42
227W223-3-01-0 Heat Shrink Boots
  • Molded Part Shape 90°
  • Lipped No
  • Material Code 3
  • Heat Shrink Boot Material Systems Code 10
  • Adhesive Pre-Coat No
  • Operating Temperature Range -55 – 135
  • Molded Part Shape Code 227W
  • Fluid/Chemical Resistance Occasional exposure to fluids