OMIT-SH-112LM,394 Power Relays  1
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 500 – 600
  • Coil Power Rating DC 540
  • Coil Resistance 270
  • Coil Special Features Sensitive Version
  • Coil Voltage Rating 12
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form A (NO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material Ag
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTIII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 70
  • Packaging Method Box & Carton
OMIT-SH-124LM,394 Power Relays  1
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 500 – 600
  • Coil Power Rating DC 540
  • Coil Resistance 1100
  • Coil Special Features Sensitive Version
  • Coil Voltage Rating 24
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form A (NO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTIII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 70
  • Packaging Method Box & Carton
OMIT-SS-109LM,300 Power Relays
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 500 – 600
  • Coil Power Rating DC 540
  • Coil Resistance 155
  • Coil Special Features Sensitive Version
  • Coil Voltage Rating 9
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form A (NO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material Ag
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 70
  • Packaging Method Box & Carton
OMIT-SH-105D,394 Power Relays
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 600 – 800
  • Coil Power Rating DC 720
  • Coil Resistance 36
  • Coil Special Features UL Coil Insulation Class A
  • Coil Voltage Rating 5
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form C (CO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTIII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 60
  • Packaging Method Box & Carton
OMIT-SH-105DM,394 Power Relays
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 600 – 800
  • Coil Power Rating DC 720
  • Coil Resistance 36
  • Coil Special Features UL Coil Insulation Class A
  • Coil Voltage Rating 5
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form A (NO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTIII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 60
  • Packaging Method Box & Carton
OMIT-SH-105L,394 Power Relays
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 500 – 600
  • Coil Power Rating DC 540
  • Coil Resistance 48.5
  • Coil Special Features Sensitive Version
  • Coil Voltage Rating 5
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form C (CO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTIII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 70
  • Packaging Method Box & Carton
OMIT-SH-105LM,394 Power Relays
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 500 – 600
  • Coil Power Rating DC 540
  • Coil Resistance 48.5
  • Coil Special Features Sensitive Version
  • Coil Voltage Rating 5
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form A (NO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTIII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 70
  • Packaging Method Box & Carton
OMIT-SH-106D,394 Power Relays
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 600 – 800
  • Coil Power Rating DC 720
  • Coil Resistance 48.5
  • Coil Special Features UL Coil Insulation Class A
  • Coil Voltage Rating 6
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form C (CO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTIII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 60
  • Packaging Method Box & Carton
OMIT-SH-106DM,394 Power Relays
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 600 – 800
  • Coil Power Rating DC 720
  • Coil Resistance 48.5
  • Coil Special Features UL Coil Insulation Class A
  • Coil Voltage Rating 6
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form A (NO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTIII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 60
  • Packaging Method Box & Carton
OMIT-SH-106L,394 Power Relays
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 500 – 600
  • Coil Power Rating DC 540
  • Coil Resistance 68
  • Coil Special Features Sensitive Version
  • Coil Voltage Rating 6
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form C (CO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTIII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 70
  • Packaging Method Box & Carton
OMIT-SH-106LM,394 Power Relays
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 500 – 600
  • Coil Power Rating DC 540
  • Coil Resistance 68
  • Coil Special Features Sensitive Version
  • Coil Voltage Rating 6
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form A (NO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTIII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 70
  • Packaging Method Box & Carton
OMIT-SH-109D,394 Power Relays
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 600 – 800
  • Coil Power Rating DC 720
  • Coil Resistance 115
  • Coil Special Features UL Coil Insulation Class A
  • Coil Voltage Rating 9
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form C (CO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTIII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 60
  • Packaging Method Box & Carton
OMIT-SH-109DM,394 Power Relays
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 600 – 800
  • Coil Power Rating DC 720
  • Coil Resistance 115
  • Coil Special Features UL Coil Insulation Class A
  • Coil Voltage Rating 9
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form A (NO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTIII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 60
  • Packaging Method Box & Carton
OMIT-SH-109L,394 Power Relays
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 500 – 600
  • Coil Power Rating DC 540
  • Coil Resistance 155
  • Coil Special Features Sensitive Version
  • Coil Voltage Rating 9
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form C (CO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTIII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 70
  • Packaging Method Box & Carton
OMIT-SH-109LM,300 Power Relays
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 500 – 600
  • Coil Power Rating DC 540
  • Coil Resistance 155
  • Coil Special Features Sensitive Version
  • Coil Voltage Rating 9
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form A (NO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTIII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 70
  • Packaging Method Box & Carton
OMIT-SH-109LM,394 Power Relays
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 500 – 600
  • Coil Power Rating DC 540
  • Coil Resistance 155
  • Coil Special Features Sensitive Version
  • Coil Voltage Rating 9
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form A (NO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTIII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 70
  • Packaging Method Box & Carton
OMIT-SH-112D,394 Power Relays
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 600 – 800
  • Coil Power Rating DC 720
  • Coil Resistance 200
  • Coil Special Features UL Coil Insulation Class A
  • Coil Voltage Rating 12
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form C (CO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTIII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 60
  • Packaging Method Box & Carton
OMIT-SH-112DM,394 Power Relays
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 600 – 800
  • Coil Power Rating DC 720
  • Coil Resistance 200
  • Coil Special Features UL Coil Insulation Class A
  • Coil Voltage Rating 12
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form A (NO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTIII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 60
  • Packaging Method Box & Carton
OMIT-SH-112L,394 Power Relays
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 500 – 600
  • Coil Power Rating DC 540
  • Coil Resistance 270
  • Coil Special Features Sensitive Version
  • Coil Voltage Rating 12
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form C (CO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTIII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 70
  • Packaging Method Box & Carton
OMIT-SH-124D,394 Power Relays
  • Power Relay Type Standard
  • Contact Limiting Breaking Current 10
  • Coil Magnetic System Monostable, DC
  • Coil Power Rating Class 600 – 800
  • Coil Power Rating DC 720
  • Coil Resistance 820
  • Coil Special Features UL Coil Insulation Class A
  • Coil Voltage Rating 24
  • Contact Switching Load (Min) 100mA @ 5V
  • Contact Switching Voltage (Max) 240
  • Contact Switching Voltage (Max) 30
  • Contact Voltage Rating 240
  • Insulation Initial Dielectric Between Contacts & Coil 5000
  • Contact Limiting Continuous Current 10
  • Insulation Creepage Between Contact & Coil 8
  • Contact Limiting Making Current 10
  • Insulation Initial Resistance 1000
  • Insulation Creepage Class 5.5 – 8
  • Contact Limiting Short-Time Current 10
  • Insulation Initial Dielectric Between Open Contacts 1000
  • Insulation Initial Dielectric Between Coil & Contact Class 4000
  • Weight 13
  • Insulation Special Features 10000V Initial Surge Withstand Voltage between Contacts & Coil
  • Contact Arrangement 1 Form C (CO)
  • Contact Current Class 5 – 10
  • Contact Current Rating (Max) 10
  • Contact Material AgSnO
  • Contact Number of Poles 1
  • Terminal Type PCB-THT
  • Relay Mounting Type Printed Circuit Board
  • Width Class (Mechanical) 12 – 16
  • Length 29.21
  • Insulation Clearance Class 5 – 8
  • Width 12.8
  • Insulation Clearance Between Contact & Coil 5.5
  • Height Class (Mechanical) 20 – 25
  • Height 20.6
  • Length Class (Mechanical) 25 – 30
  • Environmental Category of Protection RTIII
  • Environmental Ambient Temperature Class 50 – 70
  • Environmental Ambient Temperature (Max) 60
  • Packaging Method Box & Carton