444442-2 Hard Wired Box Accessories  1
  • Accessory Type Others
  • UL Flammability Rating UL 94V-HB
  • Operating Temperature Range -40 – 105
  • Vibration Class Level 3G
2141034-1 Battery Distribution Unit
  • Fuse Type SF 30 Fuse
  • Sealable No
  • Number of Fuses (Minimum) 8
  • Nominal Voltage Architecture 14
  • Operating Voltage 14
  • Fuse Termination Screw
  • Battery Termination Screw/hole
  • Operating Temperature Range -40 – 85
  • Degree of Protection IP2X
  • UL Flammability Rating UL 94V-HB
444442-1 Hard Wired Box Accessories  1
  • Accessory Type Others
  • UL Flammability Rating UL 94V-HB
  • Operating Temperature Range -40 – 105
  • Vibration Class Level 3G
953653-2 Hard Wired Box Accessories  1
  • Accessory Type Brackets
  • UL Flammability Rating UL 94V-HB
  • Operating Temperature Range -40 – 85
  • Vibration Class Level 3G
1534968-2 Hard Wired Box Accessories
  • Accessory Type Screw
  • UL Flammability Rating None
  • Operating Temperature Range -40 – 105
444308-2 Module Component  1
  • Component Type Others
  • Fuse Type Type A Fuse
  • Relay Type Micro Relay
  • Sealable No
  • Other Component Type Others
  • Number of Fuses (Minimum) 30
  • Number of Relays (Minimum) 6
  • Operating Voltage 12
  • Terminal Primary Locking Feature Locking Lance
  • Secondary Locking No
  • UL Flammability Rating UL 94V-HB
  • Operating Temperature Range -40 – 105
  • Vibration Class Level 3G
  • Coupling with Other TE Modules Yes
1801627-2 Module Component  1
  • Component Type Fuse Holder
  • Fuse Type High Current Fuse
  • Sealable No
  • Number of Fuses (Minimum) 2
  • Operating Voltage 12
  • Terminal Primary Locking Feature Locking Lance
  • Secondary Locking No
  • UL Flammability Rating UL 94V-HB
  • Operating Temperature Range -40 – 100
  • Vibration Class Level 3G
  • Coupling with Other TE Modules Yes
1544266-1 Hard Wired Boxes with Busbars
  • Fuse Type Miniature Fuse
  • Connector System Wire-to-Device
  • Sealable No
  • Connector & Contact Terminates To Wire & Cable
  • Number of Fuses (Minimum) 12
  • Number of Fuse with Common Line 12
  • Number of Positions 19
  • Terminal Primary Locking Feature Clean Body
  • Secondary Locking Yes
  • Contact Current Rating (Max) 20
  • Power Termination Terminal
  • Connector Mounting Type Panel
  • Centerline (Pitch) 8
  • Operating Temperature Range -40 – 80
  • Vibration Class Level 3G
  • Circuit Application Power
  • Operating Voltage 14
  • UL Flammability Rating UL 94V-HB
1544647-1 Hard Wired Boxes with Busbars  1
  • Fuse Type Medium Fuse
  • Sealable No
  • Number of Fuses (Minimum) 5
  • Number of Fuse with Common Line 5
  • Terminal Primary Locking Feature Clean Body
  • Secondary Locking Yes
  • Power Termination Terminal
  • Operating Temperature Range -40 – 185
  • Vibration Class Level 3G
  • UL Flammability Rating UL 94V-HB
1801614-4 Busbars & Terminals  1
  • Sealable No
  • Operating Voltage 12
  • Interface Plating Tin (Sn)
  • Mating Tab Width 2.8
  • Mating Tab Thickness .8
  • Wire Size 6
  • Operating Temperature Range -40 – 85
  • Vibration Class Level 3G
2141033-1 Hard Wired Box Accessories
  • Accessory Type Cover
  • UL Flammability Rating UL 94V-HB
  • Operating Temperature Range -40 – 85
  • Degree of Protection IP2X
1355863-1 Module Component  1
  • Component Type Others
  • Sealable No
  • Operating Voltage 14
  • Secondary Locking Yes
  • UL Flammability Rating UL 94V-HB
  • Operating Temperature Range -40 – 85
  • Degree of Protection IP2X
1355864-1 Module Component  1
  • Component Type Others
  • Sealable No
  • Operating Voltage 14
  • Secondary Locking Yes
  • UL Flammability Rating UL 94V-HB
  • Operating Temperature Range -40 – 85
  • Degree of Protection IP2X
1380004-1 Busbars & Terminals  1
  • Sealable No
  • Interface Plating Tin (Sn)
  • Terminal Primary Locking Feature Locking Lance
  • Termination Method Crimp
  • Wire Size Search 4
  • Wire Size Search 9
  • Wire Size 4 – 6
  • Wire Size 11 – 9
  • Wire Insulation Diameter 3.2 – 4.3
1380006-1 Other Hard Wired Boxes  1
  • Other Component Type Others
  • Component Type Relay Holder
  • Sealable No
  • Number of Relays (Minimum) 2
  • Operating Voltage 12
  • Terminal Primary Locking Feature Locking Lance
  • Secondary Locking Yes
  • Operating Temperature (Max) 105
  • UL Flammability Rating UL 94V-HB
  • Operating Temperature Range -40 – 105
  • Vibration Class Level 25G
1380006-2 Other Hard Wired Boxes  1
  • Other Component Type Others
  • Component Type Relay Holder
  • Relay Type Mini Relay
  • Sealable No
  • Number of Relays (Minimum) 2
  • Operating Voltage 12
  • Terminal Primary Locking Feature Locking Lance
  • Secondary Locking Yes
  • Operating Temperature (Max) 105
  • UL Flammability Rating UL 94V-HB
  • Operating Temperature Range -40 – 105
  • Vibration Class Level 25G
1599962-1 Other Hard Wired Boxes  1
  • Other Component Type Others
  • Component Type Fuse Holder
  • Fuse Type Medium Fuse
  • Sealable No
  • Number of Fuses (Minimum) 8
  • Operating Voltage 12
  • Terminal Primary Locking Feature Locking Lance
  • Secondary Locking No
  • Operating Temperature (Max) 105
  • UL Flammability Rating UL 94V-HB
  • Operating Temperature Range -40 – 105
  • Vibration Class Level 25G
1801614-3 Busbars & Terminals  1
  • Sealable No
  • Operating Voltage 12
  • Interface Plating Tin (Sn)
  • Mating Tab Width 2.8
  • Mating Tab Thickness .8
  • Operating Temperature Range -40 – 85
  • Vibration Class Level 3G
1801627-3 Module Component  1
  • Component Type Fuse Holder
  • Fuse Type High Current Fuse
  • Sealable No
  • Number of Fuses (Minimum) 2
  • Operating Voltage 12
  • Terminal Primary Locking Feature Clean Body
  • Secondary Locking No
  • UL Flammability Rating UL 94V-HB
  • Operating Temperature Range -40 – 85
  • Vibration Class Level 3G
  • Coupling with Other TE Modules Yes
1801764-1 Module Component  1
  • Component Type Fuse Holder
  • Fuse Type Miniature Fuse
  • Relay Type Mini Relay
  • Sealable No
  • Other Component Type Shunt
  • Number of Fuses (Minimum) 36
  • Number of Relays (Minimum) 2
  • Operating Voltage 12
  • Terminal Primary Locking Feature Locking Lance
  • Secondary Locking No
  • UL Flammability Rating UL 94V-HB
  • Operating Temperature Range -40 – 100
  • Vibration Class Level 3G
  • Coupling with Other TE Modules Yes