2084351-1 Insulating Connectors  1
EN 50483-4 GB 2317 GB 9327
  • Technology Piercing
  • Piercing (Main & Tap) Yes
  • Piercing Blade Base Material Tinned Copper
  • Product Family Insulation Piercing Connector
  • Number of Bolts 2
  • Voltage Class ≤ 1
  • Conductor Insulation XLPE
  • Current Rating 712
  • Shear Head Breaking Torque 36 – 44
  • Shear Head System Yes
  • Conductor Range (Main) 150 – 240
  • Conductor Range (Tap) 150 – 240
  • Shear Head Size (Across Flats) 17
  • Wire Insulation Thickness (Max) 2
  • Overhead Yes
  • Application Type Main-to-Main Lines
  • Standard Reference EN 50483-4 / GB 9327 / GB2317
  • Product Availability China
  • Minimum Order Quantity 25
  • Minimum Packaging Unit 150
  • Installation Temperature Range -20 – 55
2084533-1 Insulating Connectors  1
EN 50483-4 GB 2317 GB 9327 NFC 33 020
  • Technology Piercing
  • Piercing (Main & Tap) Yes
  • Piercing Blade Base Material Tinned Copper
  • Product Family Insulation Piercing Connector
  • Number of Bolts 1
  • Voltage Class ≤ 1
  • Conductor Insulation XLPE
  • Current Rating 138
  • Weight 112
  • Shear Head Breaking Torque 9.9 – 12.1
  • Shear Head System Yes
  • Conductor Range (Main) 16 – 95
  • Conductor Range (Tap) 4 – 35 (50)
  • Shear Head Size (Across Flats) 13
  • Wire Insulation Thickness (Max) 2
  • Overhead Yes
  • Application Type Insulated Service Line
  • Standard Reference EN 50483-4 / GB 9327 / GB2317 / NFC 33 020
  • Product Availability China
  • Minimum Order Quantity 50
  • Minimum Packaging Unit 150
  • Installation Temperature Range -20 – 55
2084957-1 Insulating Connectors  1
EN 50483-4 GB 2317 GB 9327 NFC 33 020
  • Technology Piercing
  • Piercing (Main & Tap) Yes
  • Piercing Blade Base Material Aluminum Alloy
  • Product Family Insulation Piercing Connector
  • Number of Bolts 1
  • Voltage Class ≤ 1
  • Conductor Insulation XLPE
  • Current Rating 138
  • Weight 108
  • Shear Head Breaking Torque 9.9 – 12.1
  • Shear Head System Yes
  • Conductor Range (Main) 16 – 95
  • Conductor Range (Tap) 4 – 35 (50)
  • Shear Head Size (Across Flats) 13
  • Wire Insulation Thickness (Max) 2
  • Overhead Yes
  • Application Type Insulated Service Line
  • Standard Reference EN 50483-4 / GB 9327 / GB2317 / NFC 33 020
  • Product Availability China
  • Minimum Order Quantity 50
  • Minimum Packaging Unit 150
  • Installation Temperature Range -20 – 55
2084957-2 Insulating Connectors  1
EN 50483-4 GB 2317 GB 9327 NFC 33 020
  • Technology Piercing
  • Piercing (Main & Tap) Yes
  • Piercing Blade Base Material Aluminum Alloy
  • Product Family Insulation Piercing Connector
  • Number of Bolts 1
  • Voltage Class ≤ 1
  • Conductor Insulation XLPE
  • Current Rating 138
  • Weight 118
  • Shear Head Breaking Torque 9.9 – 12.1
  • Shear Head System Yes
  • Conductor Range (Main) 50 – 150
  • Conductor Range (Tap) 6 – 35 (50)
  • Shear Head Size (Across Flats) 13
  • Wire Insulation Thickness (Max) 2
  • Overhead Yes
  • Application Type Insulated Service Line
  • Standard Reference EN 50483-4 / GB 9327 / GB2317 / NFC 33 020
  • Product Availability China
  • Minimum Order Quantity 50
  • Minimum Packaging Unit 150
  • Installation Temperature Range -20 – 55
2259224-1 Insulating Connectors  1
EN 50483-4 GB 2317 GB 9327 NFC 33 020
  • Technology Piercing
  • Piercing (Main & Tap) Yes
  • Piercing Blade Base Material Tinned Copper
  • Product Family Insulation Piercing Connector
  • Number of Bolts 2
  • Voltage Class ≤ 1
  • Conductor Insulation XLPE
  • Current Rating 239
  • Weight 342
  • Shear Head Breaking Torque 19.8 – 24.2
  • Shear Head System Yes
  • Conductor Range (Main) 50 – 150
  • Conductor Range (Tap) 50 – 150
  • Shear Head Size (Across Flats) 13
  • Wire Insulation Thickness (Max) 2
  • Overhead Yes
  • Application Type Main-to-Main Lines
  • Standard Reference EN 50483-4 / GB 9327 / GB2317 / NFC 33 020
  • Product Availability China
  • Minimum Order Quantity 25
  • Minimum Packaging Unit 150
  • Installation Temperature Range -20 – 55
2259231-1 Insulating Connectors  1
EN 50483-4 GB 2317 GB 9327 NFC 33 020
  • Technology Piercing
  • Piercing (Main & Tap) Yes
  • Piercing Blade Base Material Tinned Copper
  • Product Family Insulation Piercing Connector
  • Number of Bolts 1
  • Voltage Class ≤ 1
  • Conductor Insulation XLPE
  • Current Rating 207
  • Weight 158
  • Shear Head Breaking Torque 16.2 – 19.8
  • Shear Head System Yes
  • Conductor Range (Main) 25 – 95
  • Conductor Range (Tap) 25 – 95
  • Shear Head Size (Across Flats) 13
  • Wire Insulation Thickness (Max) 2
  • Overhead Yes
  • Application Type Main-to-Main Lines
  • Standard Reference EN 50483-4 / GB 9327 / GB2317 / NFC 33 020
  • Product Availability China
  • Minimum Order Quantity 50
  • Minimum Packaging Unit 150
  • Installation Temperature Range -20 – 55