2197666-1 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Stress Cone
  • Cable Shield Style Tape
  • Insulation XLPE/EPR
  • Sheds per Phase 3
  • Termination Length 289
  • Shelf Life 2 Years
  • Number of Cores 1
  • Voltage Class ≤ 17.5
  • Cross-Section Range 25 – 35
  • Insulation Diameter 11.7 – 18
  • Shed Diameter 38
  • Length (Installed) 1000
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) II
  • Design Specification GB/T 12706.4
  • Product Availability China
2197666-2 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Stress Cone
  • Cable Shield Style Tape
  • Insulation XLPE/EPR
  • Sheds per Phase 3
  • Termination Length 296
  • Shelf Life 2 Years
  • Number of Cores 1
  • Voltage Class ≤ 17.5
  • Cross-Section Range 35 – 120
  • Insulation Diameter 16.9 – 26
  • Shed Diameter 42
  • Length (Installed) 1000
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) II
  • Design Specification GB/T 12706.4
  • Product Availability China
2197666-3 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Stress Cone
  • Cable Shield Style Tape
  • Insulation XLPE/EPR
  • Sheds per Phase 3
  • Termination Length 304
  • Shelf Life 2 Years
  • Number of Cores 1
  • Voltage Class ≤ 17.5
  • Cross-Section Range 150 – 300
  • Insulation Diameter 24.7 – 38
  • Shed Diameter 48
  • Length (Installed) 1000
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) II
  • Design Specification GB/T 12706.4
  • Product Availability China
2197666-4 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Stress Cone
  • Cable Shield Style Tape
  • Insulation XLPE/EPR
  • Sheds per Phase 3
  • Termination Length 309
  • Shelf Life 2 Years
  • Number of Cores 1
  • Voltage Class ≤ 17.5
  • Cross-Section Range 400 – 630
  • Insulation Diameter 32.5 – 50
  • Shed Diameter 54
  • Length (Installed) 1000
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) II
  • Design Specification GB/T 12706.4
  • Product Availability China
2259749-1 Power Cable Terminations  1
GB/T 28427
  • Technology Stress Cone
  • Cable Shield Style Wire
  • Sheds per Phase 7
  • Termination Length 460
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) Yes
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) Yes
  • Number of Cores 1
  • Voltage Class ≤ 52
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) No
  • Armoring AL Wire
  • Cross-Section Range 150
  • Insulation Diameter 37 – 41
  • Length (Installed) 900
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) I
  • Design Specification GB/T 28427
  • Product Availability China
2259749-2 Power Cable Terminations  1
GB/T 28427
  • Technology Stress Cone
  • Cable Shield Style Wire
  • Sheds per Phase 7
  • Termination Length 460
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) Yes
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) Yes
  • Number of Cores 1
  • Voltage Class ≤ 52
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) No
  • Armoring AL Wire
  • Cross-Section Range 185
  • Insulation Diameter 41 – 47
  • Length (Installed) 900
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) I
  • Design Specification GB/T 28427
  • Product Availability China
2259749-3 Power Cable Terminations  1
GB/T 28427
  • Technology Stress Cone
  • Cable Shield Style Wire
  • Sheds per Phase 7
  • Termination Length 460
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) Yes
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) Yes
  • Number of Cores 1
  • Voltage Class ≤ 52
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) No
  • Armoring AL Wire
  • Cross-Section Range 240
  • Insulation Diameter 40 – 47
  • Length (Installed) 900
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) I
  • Design Specification GB/T 28427
  • Product Availability China
2259749-4 Power Cable Terminations  1
GB/T 28427
  • Technology Stress Cone
  • Cable Shield Style Wire
  • Sheds per Phase 7
  • Termination Length 460
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) Yes
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) Yes
  • Number of Cores 1
  • Voltage Class ≤ 52
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) No
  • Armoring AL Wire
  • Cross-Section Range 300
  • Insulation Diameter 40 – 47
  • Length (Installed) 900
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) I
  • Design Specification GB/T 28427
  • Product Availability China
2259749-5 Power Cable Terminations  1
GB/T 28427
  • Technology Stress Cone
  • Cable Shield Style Wire
  • Sheds per Phase 7
  • Termination Length 460
  • Mechanical Lug Included (Shield) No
  • Compression Lug Included (Conductor) Yes
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) Yes
  • Number of Cores 1
  • Voltage Class ≤ 52
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) No
  • Armoring AL Wire
  • Cross-Section Range 400
  • Insulation Diameter 47 – 53
  • Length (Installed) 900
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) I
  • Design Specification GB/T 28427
  • Product Availability China
2259766-1 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Stress Cone
  • Cable Shield Style Tape
  • Insulation XLPE/EPR
  • Sheds per Phase 3
  • Termination Length 289
  • Shelf Life 2 Years
  • Number of Cores 3
  • Voltage Class ≤ 17.5
  • Armoring Steel Tape
  • Cross-Section Range 25 – 35
  • Insulation Diameter 11.7 – 18
  • Shed Diameter 38
  • Length (Installed) 1000
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) II
  • Design Specification GB/T 12706.4
  • Product Availability China
2259766-2 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Stress Cone
  • Cable Shield Style Tape
  • Insulation XLPE/EPR
  • Sheds per Phase 3
  • Termination Length 296
  • Shelf Life 2 Years
  • Number of Cores 3
  • Voltage Class ≤ 17.5
  • Armoring Steel Tape
  • Cross-Section Range 50 – 150
  • Insulation Diameter 16.9 – 26
  • Shed Diameter 42
  • Length (Installed) 1000
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) II
  • Design Specification GB/T 12706.4
  • Product Availability China
2259766-3 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Stress Cone
  • Cable Shield Style Tape
  • Insulation XLPE/EPR
  • Sheds per Phase 3
  • Termination Length 304
  • Shelf Life 2 Years
  • Number of Cores 3
  • Voltage Class ≤ 17.5
  • Armoring Steel Tape
  • Cross-Section Range 185 – 400
  • Insulation Diameter 24.7 – 38
  • Shed Diameter 48
  • Length (Installed) 1000
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) II
  • Design Specification GB/T 12706.4
  • Product Availability China
2259766-4 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Stress Cone
  • Cable Shield Style Tape
  • Insulation XLPE/EPR
  • Sheds per Phase 3
  • Termination Length 309
  • Shelf Life 2 Years
  • Number of Cores 3
  • Voltage Class ≤ 17.5
  • Armoring Steel Tape
  • Cross-Section Range 400 – 500
  • Insulation Diameter 32.5 – 50
  • Shed Diameter 54
  • Length (Installed) 1000
  • Operating Temperature Range -40 – 40
  • Application Type Indoor
  • Pollution Level (IEC 60815) II
  • Design Specification GB/T 12706.4
  • Product Availability China
EF1622-011 Power Cable Terminations  1
HD CENELEC 629.1 IEC 60502-4
  • Technology Cold Applied
  • Cable Shield Style Wire
  • Insulation XLPE/EPR
  • Sheds per Phase 3
  • Mechanical Connectors Included Yes
  • Mechanical Lug Included (Shield) Yes
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) No
  • Number of Cores 1
  • Voltage Class ≤ 24
  • Mechanical Lug Included (M12, Conductor) Yes
  • Mechanical Lug Included (M16, Conductor) No
  • Cross-Section Range 25 – 95
  • Insulation Diameter 17.9 – 25.
  • Shed Diameter 49 – 75
  • Sheath Outside Diameter 34
  • Application Type Indoor
  • Design Specification CENELEC HD 629.1
  • Product Availability AMERICAS
  • Installation Instruction English
EF1623-011 Power Cable Terminations  1
HD CENELEC 629.1 IEC 60502-4
  • Technology Cold Applied
  • Cable Shield Style Wire
  • Insulation XLPE/EPR
  • Sheds per Phase 3
  • Mechanical Connectors Included Yes
  • Mechanical Lug Included (Shield) Yes
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) No
  • Number of Cores 1
  • Voltage Class ≤ 24
  • Mechanical Lug Included (M12, Conductor) Yes
  • Mechanical Lug Included (M16, Conductor) No
  • Cross-Section Range 95 – 240
  • Insulation Diameter 25. – 32.
  • Shed Diameter 49 – 75
  • Sheath Outside Diameter 50
  • Application Type Indoor
  • Design Specification CENELEC HD 629.1
  • Product Availability AMERICAS
  • Installation Instruction English
EF1624-011 Power Cable Terminations  1
HD CENELEC 629.1 IEC 60502-4
  • Technology Cold Applied
  • Cable Shield Style Wire
  • Insulation XLPE/EPR
  • Sheds per Phase 3
  • Mechanical Connectors Included Yes
  • Mechanical Lug Included (Shield) Yes
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) No
  • Number of Cores 1
  • Voltage Class ≤ 24
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) No
  • Cross-Section Range 300 – 400
  • Insulation Diameter 32.6 – 37.8
  • Shed Diameter 49 – 75
  • Sheath Outside Diameter 58
  • Application Type Indoor
  • Design Specification CENELEC HD 629.1
  • Product Availability AMERICAS
  • Installation Instruction English
EF1625-011 Power Cable Terminations  1
HD CENELEC 629.1 IEC 60502-4
  • Technology Cold Applied
  • Cable Shield Style Wire
  • Insulation XLPE/EPR
  • Sheds per Phase 3
  • Mechanical Connectors Included Yes
  • Mechanical Lug Included (Shield) Yes
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) No
  • Number of Cores 1
  • Voltage Class ≤ 24
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) Yes
  • Cross-Section Range 500 – 630
  • Insulation Diameter 42.6 – 49.2
  • Shed Diameter 49 – 75
  • Sheath Outside Diameter 58
  • Application Type Indoor
  • Design Specification CENELEC HD 629.1
  • Product Availability AMERICAS
  • Installation Instruction English
EK6583-011 Power Cable Terminations  1
HD CENELEC 629.1 IEC 60502-4
  • Technology Cold Applied
  • Cable Shield Style Wire
  • Insulation XLPE/EPR
  • Sheds per Phase 7
  • Mechanical Connectors Included Yes
  • Mechanical Lug Included (Shield) Yes
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) No
  • Number of Cores 1
  • Voltage Class ≤ 36
  • Mechanical Lug Included (M12, Conductor) Yes
  • Mechanical Lug Included (M16, Conductor) No
  • Cross-Section Range 95 – 150
  • Insulation Diameter 27.8 – 33.5
  • Shed Diameter 73 – 100
  • Sheath Outside Diameter 46
  • Application Type Indoor
  • Design Specification CENELEC HD 629.1
  • Product Availability AMERICAS
  • Installation Instruction English
EK7005-000 Power Cable Terminations  1
HD CENELEC 629.1 IEC 60502-4
  • Technology Cold Applied
  • Cable Shield Style Wire
  • Insulation XLPE/EPR
  • Sheds per Phase 7
  • Mechanical Connectors Included Yes
  • Mechanical Lug Included (Shield) Yes
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) No
  • Number of Cores 1
  • Voltage Class ≤ 36
  • Mechanical Lug Included (M12, Conductor) No
  • Mechanical Lug Included (M16, Conductor) Yes
  • Cross-Section Range 185 – 400
  • Insulation Diameter 32.4 – 42.8
  • Shed Diameter 73 – 100
  • Sheath Outside Diameter 56
  • Application Type Indoor
  • Design Specification CENELEC HD 629.1
  • Product Availability AMERICAS
  • Installation Instruction English
EK7721-000 Power Cable Terminations  1
HD CENELEC 629.1 IEC 60502-4
  • Technology Cold Applied
  • Cable Shield Style Wire
  • Insulation XLPE/EPR
  • Sheds per Phase 7
  • Mechanical Connectors Included Yes
  • Mechanical Lug Included (Shield) Yes
  • Compression Lug Included (Conductor) No
  • Shelf Life 2 Years
  • Compression Lug Included (Shield) No
  • Number of Cores 1
  • Voltage Class ≤ 36
  • Mechanical Lug Included (M12, Conductor) Yes
  • Mechanical Lug Included (M16, Conductor) No
  • Cross-Section Range 50 – 70
  • Insulation Diameter 24.5 – 28.4
  • Shed Diameter 73 – 100
  • Sheath Outside Diameter 42
  • Application Type Indoor
  • Design Specification CENELEC HD 629.1
  • Product Availability AMERICAS
  • Installation Instruction English