012839-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 2
  • Termination Length 550
  • Shelf Life No Limitation
  • Number of Cores 3
  • Voltage Class ≤ 42
  • Armoring Tape
  • Cross-Section Range 50 – 95
  • Insulation Diameter 30 – 35.1
  • Shed Diameter 95
  • Application Type Indoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
041753-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 2
  • Termination Length 550
  • Shelf Life No Limitation
  • Number of Cores 1
  • Voltage Class ≤ 42
  • Cross-Section Range 120 – 185
  • Insulation Diameter 35 – 40
  • Shed Diameter 115
  • Application Type Indoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
052121-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 4
  • Termination Length 750
  • Shelf Life No Limitation
  • Number of Cores 3
  • Voltage Class ≤ 42
  • Armoring Tape
  • Cross-Section Range 240 – 500
  • Insulation Diameter 40 – 50.3
  • Shed Diameter 135
  • Application Type Outdoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
062981-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 2
  • Termination Length 550
  • Shelf Life No Limitation
  • Number of Cores 1
  • Voltage Class ≤ 42
  • Cross-Section Range 240 – 500
  • Insulation Diameter 40 – 50.3
  • Shed Diameter 135
  • Application Type Indoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
065211-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Termination Length 400
  • Shelf Life No Limitation
  • Number of Cores 1
  • Voltage Class ≤ 17.5
  • Cross-Section Range 95 – 240
  • Insulation Diameter 21.6 – 30
  • Application Type Indoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
067563-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 4
  • Termination Length 750
  • Shelf Life No Limitation
  • Number of Cores 1
  • Voltage Class ≤ 42
  • Cross-Section Range 120 – 185
  • Insulation Diameter 35 – 40
  • Shed Diameter 115
  • Application Type Outdoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
114041-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 2
  • Termination Length 450
  • Shelf Life No Limitation
  • Number of Cores 3
  • Voltage Class ≤ 17.5
  • Armoring Tape
  • Cross-Section Range 25 – 70
  • Insulation Diameter 14 – 21.4
  • Shed Diameter 85
  • Tail Length 1200
  • Application Type Outdoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
151035-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 4
  • Termination Length 750
  • Shelf Life No Limitation
  • Number of Cores 3
  • Voltage Class ≤ 42
  • Armoring Tape
  • Cross-Section Range 120 – 185
  • Insulation Diameter 35 – 40
  • Shed Diameter 115
  • Application Type Outdoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
161857-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Termination Length 400
  • Shelf Life No Limitation
  • Number of Cores 1
  • Voltage Class ≤ 17.5
  • Cross-Section Range 500 – 800
  • Insulation Diameter 36.4 – 42.9
  • Application Type Indoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
183453-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 2
  • Termination Length 450
  • Shelf Life No Limitation
  • Number of Cores 1
  • Voltage Class ≤ 17.5
  • Cross-Section Range 500 – 800
  • Insulation Diameter 36.4 – 42.9
  • Shed Diameter 135
  • Application Type Outdoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
187515-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Termination Length 400
  • Shelf Life No Limitation
  • Number of Cores 1
  • Voltage Class ≤ 17.5
  • Cross-Section Range 35 – 70
  • Insulation Diameter 17 – 21.4
  • Application Type Indoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
233839-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 2
  • Termination Length 550
  • Shelf Life No Limitation
  • Number of Cores 1
  • Voltage Class ≤ 42
  • Cross-Section Range 50 – 95
  • Insulation Diameter 30 – 35.1
  • Shed Diameter 95
  • Application Type Indoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
263995-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 4
  • Termination Length 750
  • Shelf Life No Limitation
  • Number of Cores 3
  • Voltage Class ≤ 42
  • Armoring Tape
  • Cross-Section Range 50 – 95
  • Insulation Diameter 30 – 35.1
  • Shed Diameter 95
  • Application Type Outdoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
367148-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 2
  • Termination Length 550
  • Shelf Life No Limitation
  • Number of Cores 1
  • Voltage Class ≤ 42
  • Cross-Section Range 630 – 1000
  • Insulation Diameter 52.4 – 58.7
  • Shed Diameter 135
  • Application Type Indoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
456957-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 4
  • Termination Length 750
  • Shelf Life No Limitation
  • Number of Cores 1
  • Voltage Class ≤ 42
  • Cross-Section Range 50 – 95
  • Insulation Diameter 30 – 35.1
  • Shed Diameter 95
  • Application Type Outdoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
462669-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 2
  • Termination Length 500
  • Shelf Life No Limitation
  • Number of Cores 1
  • Voltage Class ≤ 17.5
  • Cross-Section Range 1000
  • Insulation Diameter 46.7
  • Shed Diameter 135
  • Application Type Outdoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
474427-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Termination Length 400
  • Shelf Life No Limitation
  • Number of Cores 1
  • Voltage Class ≤ 17.5
  • Cross-Section Range 300 – 400
  • Insulation Diameter 30.4 – 35.4
  • Application Type Indoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
558081-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 2
  • Termination Length 450
  • Shelf Life No Limitation
  • Number of Cores 1
  • Voltage Class ≤ 17.5
  • Cross-Section Range 300 – 400
  • Insulation Diameter 30.4 – 35.4
  • Shed Diameter 115
  • Application Type Outdoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
576864-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 4
  • Termination Length 750
  • Shelf Life No Limitation
  • Number of Cores 1
  • Voltage Class ≤ 42
  • Cross-Section Range 630 – 1000
  • Insulation Diameter 52.4 – 58.7
  • Shed Diameter 135
  • Application Type Outdoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1
582203-000 Power Cable Terminations  1
GB/T 12706.4 IEC 60502-4
  • Technology Heat Shrink
  • Cable Shield Style Tape
  • Insulation Plastic
  • Sheds per Phase 2
  • Termination Length 550
  • Shelf Life No Limitation
  • Number of Cores 3
  • Voltage Class ≤ 42
  • Armoring Tape
  • Cross-Section Range 120 – 185
  • Insulation Diameter 35 – 40
  • Shed Diameter 115
  • Application Type Indoor
  • Design Specification GB/T 12706.4
  • Product Availability China
  • Minimum Order Quantity 1
  • Minimum Packaging Unit 1