| Part |
Differing Features |

|
- Government/Industry Qualification = No
- Output Voltage Rating (DC Relays) = 60 VDC
- Insulation - Initial Dielectric Between Contacts and Coil = 1000 V rms
- Screening Level = Y
|
- Termination Type = Through Hole
- With Short Circuit Protection/Control Status
- CII
|
| Not EU RoHS or ELV Compliant, Not applicable for solder process capability |
|
|
|

|
- Government/Industry Qualification = Yes
- M28750/9-001Y
- Output Voltage Rating (AC Relays) = 250 V rms
- Insulation - Initial Dielectric Between Contacts and Coil = 1500 V rms
|
- Screening Level = Y
- Termination Type = Through Hole
- Additional Features = None
- CII
|
| Not EU RoHS or ELV Compliant, Not solder process capable |
|
|
|

|
- Government/Industry Qualification = No
- Output Voltage Rating (DC Relays) = 60 VDC
- Insulation - Initial Dielectric Between Contacts and Coil = 1000 V rms
- Screening Level = Y
|
- Termination Type = Surface Mount
- With Short Circuit Protection
- CII
|
| Not EU RoHS or ELV Compliant, Not applicable for solder process capability |
|
|
|

|
- Government/Industry Qualification = No
- Output Voltage Rating (DC Relays) = 60 VDC
- Insulation - Initial Dielectric Between Contacts and Coil = 1000 V rms
- Screening Level = Y
|
- Termination Type = Through Hole
- With Short Circuit Protection
- CII
|
| Not EU RoHS or ELV Compliant, Not applicable for solder process capability |
|
|
|

|
- Government/Industry Qualification = No
- Output Voltage Rating (DC Relays) = 60 VDC
- Insulation - Initial Dielectric Between Contacts and Coil = 1000 V rms
- Screening Level = Y
|
- Termination Type = Through Hole
- With Short Circuit Protection/Switch Status
- CII
|
| Not EU RoHS or ELV Compliant, Not applicable for solder process capability |
|
|
|

|
- Government/Industry Qualification = No
- Output Voltage Rating (DC Relays) = 60 VDC
- Insulation - Initial Dielectric Between Contacts and Coil = 1000 V rms
- Screening Level = Y
|
- Termination Type = Through Hole
- Additional Features = None
- CII
|
| Not EU RoHS or ELV Compliant, Not applicable for solder process capability |
|
|
|

|
- Government/Industry Qualification = No
- Output Voltage Rating (DC Relays) = 60 VDC
- Insulation - Initial Dielectric Between Contacts and Coil = 1000 V rms
- Screening Level = Y
|
- Termination Type = Through Hole
- With Short Circuit Protection
- CII
|
| Not EU RoHS or ELV Compliant, Not applicable for solder process capability |
|
|
|

|
- Government/Industry Qualification = No
- Output Voltage Rating (DC Relays) = 60 VDC
- Insulation - Initial Dielectric Between Contacts and Coil = 1000 V rms
- Screening Level = Y
|
- Termination Type = Surface Mount
- With Short Circuit Protection
- CII
|
| Not EU RoHS or ELV Compliant, Not applicable for solder process capability |
|
|
|

|
- Government/Industry Qualification = No
- Output Voltage Rating (AC Relays) = 250 V rms
- Insulation - Initial Dielectric Between Contacts and Coil = 1500 V rms
- Screening Level = W
|
- Termination Type = Through Hole
- Additional Features = None
- Kilovac
|
| Not EU RoHS or ELV Compliant, Not applicable for solder process capability |
|
|
|

|
- Government/Industry Qualification = No
- Output Voltage Rating (DC Relays) = 60 VDC
- Insulation - Initial Dielectric Between Contacts and Coil = 1000 V rms
- Screening Level = Y
|
- Termination Type = Through Hole
- With Short Circuit Protection/Trip Status
- CII
|
| Not reviewed for RoHS Compliance, Not reviewed for solder process capability |
|
|
|

|
- Government/Industry Qualification = No
- Output Voltage Rating (DC Relays) = 60 VDC
- Insulation - Initial Dielectric Between Contacts and Coil = 1000 V rms
- Screening Level = Y
|
- Termination Type = Surface Mount
- With Short Circuit Protection/Control Status
- CII
|
| Not reviewed for RoHS Compliance, Not reviewed for solder process capability |
|
|
|